Digital Access Keypad Manual
SECO-LARM U.S.A., Inc.
Digital Access Keypad Manual
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
_____________________________________________________________________________________
ENFORCER
1 2 3
4 5 6
7 8 9
*
0 #
Power:
• Operation voltage -- 12-24 Volts AC/DC. No jumper needed to set voltage.
• Stand-by current drain -- 10mA @12VDC.
• Active current drain (press keypad key) -- Under 30mA.
• Active current drain (one relay activated) -- Under 80mA.
• Active current drain (two relays activated) -- Under 130mA.
Outputs:
• Relay output #1 -- 5A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second timed
output or shunt (start/stop) output. Three terminals.
• Relay output #2 -- 1A @ 28VDC, Form "C", N.O./C./N.C., programmable for 1 to 999 second momentary
output or shunt (start/stop) output. Three wires.
• Output #3 -- Transistor ground, max. 100mA @ 24VDC, programmable for 1 to 999 second momentary
output or shunt (start/stop) output. Single wire.
• Tamper output -- N.C. output. Connect to tamper circuit of alarm control panel. Two wires.
• Keypad active or alarm output -- Transistor ground, max. 100mA @ 24VDC. Switches to ground (-) for 10
sec. when a key is pressed (keypad active output), or switches to ground (-) to indicate a door was forced
open or propped open (alarm output). Single wire.
• Mantrap (interlock) control output -- Outputs ground (-) for five seconds after relay output #1 is activated,
continues while the door is open. Use to disable a second keypad during this time. Single wire.
• Ground output -- Steady ground (-), 100mA @ 24VDC. Single wire.
• Duress output -- Transistor ground (-), 100mA @ 24VDC. Single wire.
Inputs:
• Power -- 12-24Volts AC/DC. Two wires.
• Egress -- N.O., ground (-). Single wire.
• Door sensor input -- N.C., ground (-). Connect to an N.C. magnetic contact to show if door is opened or
closed, or connect to ground (-) if not used. Single wire.
• Green LED input -- Connect to operate green LED as needed. Two wires.
• Red LED input -- Connect to operate red LED as needed. Two wires.
• Auxiliary LED input -- Connect to (-) to turn the center LED to red as needed. Single wire.
• Relay output #1 disable input -- Connect to ground (-) to prevent relay output #1 from operating, or to the
mantrap (interlock) control output of another keypad to disable output #1 while the other keypad is active.
Single wire.
Code Operation:
• Auto or manual code entry. Up to 100 user codes for relay output #1, up to 10 user codes for relay output
#2, up to 10 user codes for output #3. 111,110,000 possible user code combinations.
Auto refresh time during code entry:
• Max. 10 seconds to enter each digit.
• Max. 30 seconds to enter each code.
Dimensions (keypad with back box):
• 4-5/8" x 2-7/8" x 1-7/8" (117 x 74 x 48 mm).
Weight (keypad with back box):
• 6.3 oz. (180 grams).
SPECIFICATIONS
1. Master Code: The SK-1131-SQ comes pre-programmed with the Master Code set at 0000. Additional codes and/or
data should be programmed at the owner's discretion. However, to ensure security, program a new personal Master
Code to replace the factory-set Master Code as soon as possible.
2. Factory defaults:
PROGRAMMING NOTES
STATUS
1. In programming mode
2. Successful key entry
3. Successful code entry
4. Unsuccessful code entry
5. DAP jumper not replaced
6. In standby mode
7. Output relay activated
BUZZER TONES*
- - -
1 beep
2 beeps
5 beeps
Continuous beeps
- - -
1-sec. long beep**
AUX. LED FLASHES
ON
1 flash
2 flashes
5 flashes
Continuous flashes
1 flash in 2-sec. intervals
- - -
NOTE: * The buzzer can be disabled through programming option 83.
** The output relay activated beep can be disabled through programming option 82.
BUZZER AND LED SIGNALS
The keypad's built-in buzzer and the auxiliary red/green LED can signal the following:
Door forced open alarm
disabled
Output activation announcer
ON
User code entry mode
manual
Keypress beep
ON
Door propped open alarm
OFF
Silent operation
OFF
Red
Red/
Green
Green
LED INDICATORS
Green LED -- Does not have a pre-determined function. Instead,
connect to a switch or output via the grey and green wires in the
wire harness.
Red LED -- Does not have a pre-determined function. Instead,
connect to a switch or output via the light blue and yellow wires in
the wire harness.
Auxiliary red/green LED -- Flashes green to show the keypad
status (see below). It also lights red when the white wire in the
wire harness is connected to ground (-) to show, for example,
that an output is activated.
4.
Using Duress Codes
: Duress codes are used to activate a separate device silently to alert a guard or other
personnel that a user is operating the keypad under threat. The keypad operates as normal, but a signal is sent to
alert others. Duress code is for output #1 only.
Duress codes do not need to be programmed. All user codes are automatically turned into duress codes by
increasing the first digit of a user code by the number 2. The code is entered the same way as a regular user code.
For example:
User code 4468 can be entered as duress code 6468
User code 9843 can be entered as duress code 1843
User code 8181 can be entered as duress code 0181
NOTE: If a user code is programmed, its duress code is unique and cannot be programmed as another user
code. For example:
If user code 4468 is programmed, its duress code of 6468 is automatically programmed. A user code of 6468 cannot
be programmed.
3. Code operation: User codes are each four to eight digits and are assigned to two-digit IDs. If all the codes have the
same number of digits, the keypad can be programmed for whether the key must be used or not after entering the
code (see programming, option 820 or 821, page 14).
The administrator can easily delete the code of one user via the two-digit ID, if the user is no longer authorized to
enter a protected area, without the need to teach the new code to all the other users.
Relay output #1 allows up to 100 user codes, while relay output #2 and output #3 allow up to 10 user codes each.
Master code
0000
User code length
4 to 8 digits
Main relay output time
1 second
Auxiliary relay output time
1 second
Transistor ground output time 1 second
Wrong code lockout
10 tries / 30 sec.
#
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
__________________________________________________________
Page 12
Page 5