background image

9

H: SMS Commands (GSM V9.2 or above only)

If you have purchased the GSM version of Enforcer, it will allow you to send SMS commands via a mobile phone to be able to arm/disarm the panel 

remotely and others. See below the different SMS commands available.

NOTE: Any text message command to the Enforcer will need to start with a valid user code.
NOTE: Text messages commands are not case sensitive except when the used outputs are activated.
NOTE: If a text messages commands is not recognised by Enforcer it will send back to the user the wrong command.

Arming via SMS text command
Example SMS command send:

Description:

Example SMS command response:

123456 Arm A

123456 = User Code. Arm A = Will arm the Enforcer in Area A.

Final Arm; Area A

123456 Arm ABCD

123456 = User Code. Arm ABCD = Will arm the Enforcer in Area ABCD.

Final Arm; Area ABCD

NOTE: If no areas are specified then all areas will arm (default). In ‘One Area’ Mode, the default will be Area A.

Disarming via SMS text command
Example SMS command send:

Description:

Example SMS command response:

123456 Disarm A

123456 = User Code. Disarm A = Will disarm Area A.

Disarm; Area A

123456 Disarm ABCD

123456 = User Code. Disarm ABCD = Will disarm the Area ABCD.

Disarm; Area ABCD

NOTE: If no areas are specified then all areas will disarm (default). In ‘One Area’ mode, the default will be Area A.

Arming with inputs bypassed via SMS text command
Example SMS command send:

Description:

Example SMS command response:

123456 Arm A Bypass 4

123456 = User Code. Arm A Bypass 4 = Arms Area A and will bypass input 
number 4.

Input Bypass; Area A Input 04

Force Arm: Area A

123456 Arm A Bypass Kitchen

123456 = User Code. Arm A Bypass Kitchen = Arms Area A and will bypass 
the input that is called Kitchen.

Input Bypass; Area A Kitchen

Force Arm: Area A

Bypassing inputs via SMS text command
Example SMS command send:

Description:

Example SMS command response:

123456 Bypass 6

123456 = User Code. Bypass 6 = In the next arming procedure, input 

number 6 will be bypassed.

Input Bypass; Area A Input 06

123456 Bypass Garage

123456 = User Code.  Bypass Garage = In the next arming procedure, the 

input called Garage will be bypassed.

Input Bypass; Area A Garage

NOTE: The name of the output has to be one word and spelled exactly as written in the panel. For example, Garage Door is not acceptable. 
It has to be written as Garage-Door in the panel and the respective command will be Garage-Door.

Содержание Enforcer 32-WE

Страница 1: ...0131 3 2009 EN50131 6 2008 EN50131 5 3 2005 A1 2008 Security Grade 2 Environmental Class II 2 EN50131 1 PD6662 2004 Security Grade 2 Environmental Class 2 INTERNAL SIREN WARNING The Enforcer 32 WE con...

Страница 2: ...enu Configure Date Time 15 4 Master Manager Menu Change Codes Configure user codes learn tags and keyfobs 16 5 Master Manager Menu Review Logs Event memory logs 19 6 Master Manager Menu SMS Phonebook...

Страница 3: ...ected High Security Encryption 128 bit high security wireless encryption protocol and intelligent wireless jamming detection User Friendly Keyfobs The fully two way wireless keyfob allows you to see t...

Страница 4: ...rm has activated for example CHAPTER 2 KEYPADS READERS here are four different devices that may be used to arm disarm the alarm system these are he main keypad the external tag reader internal tag rea...

Страница 5: ...N Programmed for Arm Area When pressed one or more areas will be armed BUTTON Programmed for Disarm Area When pressed one or more areas will disarmed I BUTTON Programmed for User Output For example wh...

Страница 6: ...eselect the area s not wanted Use keyfob Area s should automatically be assigned 1 2 3 E n f o r c e r 3 2 W E T i m e 0 2 5 3 c E n t e r Y o u r C o d e A r m A r e a s A B C D P l e a s e W a i t A...

Страница 7: ...g and select the areas or deselect the area s not wanted Use keyfob Area s should automatically be assigned 1 2 3 E n f o r c e r 3 2 W E A r m A r e a A E n t e r Y o u r C o d e D i s a r m A r e a...

Страница 8: ...uminate indicating the system is armed on the internal reader and the RED LED on the external reader present the same tag wihthin 10 seconds again and the system will be disarmed and the door will unl...

Страница 9: ...isarm Area A Disarm Area A 123456 Disarm ABCD 123456 User Code Disarm ABCD Will disarm the Area ABCD Disarm Area ABCD NOTE If no areas are specified then all areas will disarm default In One Area mode...

Страница 10: ...TE The name of the output has to be one word and spelled exactly as written in the panel For example Garage Door is not acceptable It has to be written as Garage Door in the panel and the respective c...

Страница 11: ...123456 User Code UDL The Enforcer will make an outgoing data connection to the programmed PC1 number No response as the panel is already connected to the PC1 9999 UDL 9999 Engineer Code UDL The Enfor...

Страница 12: ...a chime sound when a door input is opened This feature can be set up by your installer To disable the chime on the keypad close all doors and when c is displayed press the c key a capital C will be d...

Страница 13: ...d there will be up to 4 mobile numbers that can be programmed to send SMS alarms Please discuss this feature with your installer if required Walk Test The Walk Test function allows the testing of all...

Страница 14: ...t p u t 0 1 D A T E T I M E t x O u t p u t O f f t O u t p u t O n t b S e l e c t U s e r A u t o m a t i o n O u t p u t 0 1 O u t p u t 1 1 9 O u t p u t 1 9 S h o w C u r r e n t O u p u t S t a...

Страница 15: ...ate Time D A T E T I M E Y e a r 0 0 9 9 0 7 M o n t h 1 1 2 0 1 D a y 1 3 1 0 1 H o u r s 0 2 3 2 3 O p t i o n s 0 N o 1 Y e s S u m m e r T i m e A d j N o 0 M i n u t e s 0 5 9 3 1 C H A N G E C O...

Страница 16: ...2 A r m O n l y 3 N o n e A r e a A r m C h o i c e N o 0 U s e r N a m e _ U s e r A r m O p t i o n s 0 D i s a r m A r m 1 D i s a r m O n l y 2 A r m O n l y 3 N o n e R E V I E W L O G t t t U s...

Страница 17: ...D U s e r T y p e 0 U s e r 1 M a n a g e r U s e r A r m O p t i o n s D i s a r m A r m 0 U s e r A r m O p t i o n s 0 D i s a r m A r m 1 D i s a r m O n l y 2 A r m O n l y 3 N o n e A r e a A r...

Страница 18: ...t o n s U N L O C K I I t x t P r e s s a n d H o l d A N Y b u t t o n f o r 5 s e c o n d s u n t i l L E D s f l a s h B u t t o n A c t i o n 1 S h o w S t a t u s B u t t o n A c t i o n 0 N o A...

Страница 19: ...c c e s s C t r l L o g x R e p e a t f o r a l l E v e n t s S t a r t o f L o g t c t t b x x 0 1 0 1 0 0 1 1 4 4 U s e r o p e n D o o r U s e r 0 1 R e p e a t f o r a l l E v e n t s S t a r t o...

Страница 20: ...D B E L L T E S T x t W a l k T e s t I n p u t s I n p u t 0 1 t W a l k T e s t I n p u t 0 1 t b x x t B E L L T E S T T e s t i n g B e l l P C C O N N E C T M E N U x t x t b 7 Master Manager Men...

Страница 21: ...e r a t i o n 0 C o n n e c t t o P C 1 T e s t D i a l 2 R M S e r v i c e 3 D a t a f r o m P C 4 D a t a t o P C 5 D i a g n o s t i c s 6 C o m m i s s i o n i n g t t x t S e l e c t P C t o D i...

Страница 22: ...d i t t tx 12 Master Manager Menu Block Remote Arm 11 Master Manager Menu Credit Check Credit Number Every GSM network that offers Pay as You Go SIM cards offers the ability of the user to check the o...

Страница 23: ...S S I N P U T S E n f o r c e r 3 2 W E T i m e 0 2 5 c a P r e s s t h e A k e y t o e x i t M a n a g e r m o d e f r o m a n y m a i n m e n u i t e m d i s p l a y e d i n c a p i t a l l e t t e...

Страница 24: ...24 N Engineer Contacts and Table Alarm Company Date of Installation Site Reference Engineer Name Engineer Contact Number Installed to Grade 2 Yes No Environmental Class II Other Comments...

Страница 25: ...25 Wireless Inputs Input Name Input Areas Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 O Input Tables...

Страница 26: ...ress 1 44 RIX Address 1 45 RIX Address 1 46 RIX Address 1 47 RIX Address 1 48 RIX Address 1 49 RIX Address 1 50 RIX Address 1 51 RIX Address 2 52 RIX Address 2 53 RIX Address 2 54 RIX Address 2 55 RIX...

Страница 27: ...User Name Code Tag Keyfob 1 33 65 2 34 66 3 35 67 4 36 68 5 37 69 6 38 70 7 39 71 8 40 72 9 41 73 10 42 74 11 43 75 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57...

Страница 28: ...TRB Onboard BELL Onboard PGM1 ROX PGM2 ROX PGM3 ROX PGM4 ROX PGM5 ROX PGM6 ROX PGM7 ROX PGM8 ROX PGM9 ROX PGM10 ROX PGM11 ROX PGM12 ROX PGM13 ROX PGM14 ROX PGM15 ROX PGM16 ROX Wireless Outputs Latched...

Страница 29: ...seful life it should not be disposed of with household waste Please recycle where facilities exist Check with your Local Authority or retailer for recycling advice in your country When disposing of th...

Страница 30: ...30 S Notes...

Страница 31: ...31 S Notes...

Страница 32: ...Website www pyronix com...

Отзывы: