9
H: SMS Commands (GSM V9.2 or above only)
If you have purchased the GSM version of Enforcer, it will allow you to send SMS commands via a mobile phone to be able to arm/disarm the panel
remotely and others. See below the different SMS commands available.
NOTE: Any text message command to the Enforcer will need to start with a valid user code.
NOTE: Text messages commands are not case sensitive except when the used outputs are activated.
NOTE: If a text messages commands is not recognised by Enforcer it will send back to the user the wrong command.
Arming via SMS text command
Example SMS command send:
Description:
Example SMS command response:
123456 Arm A
123456 = User Code. Arm A = Will arm the Enforcer in Area A.
Final Arm; Area A
123456 Arm ABCD
123456 = User Code. Arm ABCD = Will arm the Enforcer in Area ABCD.
Final Arm; Area ABCD
NOTE: If no areas are specified then all areas will arm (default). In ‘One Area’ Mode, the default will be Area A.
Disarming via SMS text command
Example SMS command send:
Description:
Example SMS command response:
123456 Disarm A
123456 = User Code. Disarm A = Will disarm Area A.
Disarm; Area A
123456 Disarm ABCD
123456 = User Code. Disarm ABCD = Will disarm the Area ABCD.
Disarm; Area ABCD
NOTE: If no areas are specified then all areas will disarm (default). In ‘One Area’ mode, the default will be Area A.
Arming with inputs bypassed via SMS text command
Example SMS command send:
Description:
Example SMS command response:
123456 Arm A Bypass 4
123456 = User Code. Arm A Bypass 4 = Arms Area A and will bypass input
number 4.
Input Bypass; Area A Input 04
Force Arm: Area A
123456 Arm A Bypass Kitchen
123456 = User Code. Arm A Bypass Kitchen = Arms Area A and will bypass
the input that is called Kitchen.
Input Bypass; Area A Kitchen
Force Arm: Area A
Bypassing inputs via SMS text command
Example SMS command send:
Description:
Example SMS command response:
123456 Bypass 6
123456 = User Code. Bypass 6 = In the next arming procedure, input
number 6 will be bypassed.
Input Bypass; Area A Input 06
123456 Bypass Garage
123456 = User Code. Bypass Garage = In the next arming procedure, the
input called Garage will be bypassed.
Input Bypass; Area A Garage
NOTE: The name of the output has to be one word and spelled exactly as written in the panel. For example, Garage Door is not acceptable.
It has to be written as Garage-Door in the panel and the respective command will be Garage-Door.