background image

3

Mounting the Reflector:

Installation and Adjustment:

Sample Fixed
Mounting:

Samples For Horizontally Adjusting
Mounting:

Samples For Vertically Adjusting Mounting:

Yellow
LED

Sensitivity

Adjuster

Red LED

LED Functions:

• Red LED -- When ON, it indicates the sensor is triggered.
• Yellow LED -- When ON, it indicates that the sensor is

properly aligned with the reflector, and the sensor is not
triggered.

Sensitivity Adjustment Functions:

• Min. Setting -- The infrared signal emitted by the sensor is at

its minimum or weakest. This means the sensor can be
easily triggered by small obstructing objects.

• Max. Setting -- The infrared signal emitted by the sensor is

at its maximum or strongest. This means the sensor cannot
be easily triggered by small obstructing objects.

Installation:

1. Mount the reflector and the sensor so they face each other.
2. Connect power to the sensor. Typically the red LED will turn

ON indicating that the sensor and reflector are not yet
properly aligned.  If the yellow LED is ON (red LED OFF), it
indicates that the sensor and reflector are aligned (although
it still may be necessary to slightly adjust the alignment).

3. Turn the sensitivity knob to Max.
4. To find the correct alignment, slowly adjust the angles of the

sensor (and/or reflector) up and down and right and left.
NOTE 1: Correct alignment is reached when the red LED
turns OFF and the yellow LED turns ON.
NOTE 2: If both LEDs are OFF, the sensor is at the edge of
sensing the signal, and may not work properly.

Adjusting Sensitivity:

After the sensor and the reflector have been properly installed,
the next step is to adjust the sensor sensitivity.
1. Turn the sensitivity knob counterclockwise to “Min.”
2. Slowly turn the sensitivity knob clockwise until the yellow

LED turns ON.  Mark this position “A”.
NOTE: If the yellow LED is ON when the sensitivity knob
has been adjusted to “Min.”, then position “A” will be at “Min.”

3. Put the object to be detected between the sensor and

reflector (in about the place where the object would
normally be detected by the sensor).  The yellow LED
should turn OFF (red LED is ON)

4. Slowly turn the sensitivity knob to clockwise until the yellow

LED turns ON.  Mark this position “B”.
NOTE: If the yellow LED does not turn ON even when the
sensitivity knob has been adjusted to “Max.” then position
“B” will be at “Max.”.

5. Turn the sensitivity knob counterclockwise until it is set at

the center (midpoint) between points “A” and “B”. This will
be the suggested sensitivity setting.

Testing:

1. Power up the sensor. The yellow LED should be ON; the

red LED should be OFF.

2. Pass the object to be detected between the sensor and

reflector. The red LED should turn ON and the yellow LED
should turn OFF. This indicates that the object has been
detected.
NOTE: If a shiny object, such as a chrome-plated or
stainless-steel item, or something with reflective tape, will
be passing between the sensor and reflector, the sensor
may not be able to detect it. In this case, it may be
necessary to turn the sensitivity knob counterclockwise
until the desired sensitivity setting is obtained.

Содержание EFR-E-931-S35RRQ

Страница 1: ...pplications Weatherproof IP 66 design for indoor outdoor use Dark ON operation Pre wired 6 foot cord Adjustable sensing distance NO NC COM relay output Compact size Safety sensor for garage doors or outdoor gates Overhead door security sensor Industrial automation Detect small objects on a manufacturing line Entry detection for storefronts Assist in measuring parking distance Alarm sensor Use of t...

Страница 2: ...tore front door Black N O Gray N C White COM Relay output Multi voltage circuit Brown Blue 24 240VAC or 12 240VDC polarity not important Connection 5 wires Note 1 Can be connected to AC or DC voltage 2 Maximum cable extension length is 325 feet 100 meters Vehicle detection Factory assembly line E 931ACC RC1Q E 931ACC R E 931ACC HR1Q ...

Страница 3: ...he edge of sensing the signal and may not work properly Adjusting Sensitivity After the sensor and the reflector have been properly installed the next step is to adjust the sensor sensitivity 1 Turn the sensitivity knob counterclockwise to Min 2 Slowly turn the sensitivity knob clockwise until the yellow LED turns ON Mark this position A NOTE If the yellow LED is ON when the sensitivity knob has b...

Страница 4: ...ginal consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM de...

Отзывы: