background image

ENFORCER Voice Dialer  

SECO-LARM U.S.A., Inc. 

7

 

 

 

 

Deleting a Stored Phone Number 

1.

 

Enter the PIN number and press the [PROG] button twice or until “MEMORY” flashes on the 
LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select the number you wish to delete. 

4.

 

Press the [DEL/PAUSE] button to delete the number. 

5.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Learn 

This function is unused. 

Setting the Siren Function  

This setting allows the user to choose between an audible alarm when triggered, or a ‘silent alarm’ 
while dialing the emergency numbers. The factory default is “ON”. 

1.

 

Enter the PIN number and press the [PROG] button four times or until the alarm icon  
(

) flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. The dialer will “beep” once. 

3.

 

Press the [#/DOWN] or [*/UP] button to select either “SOUND ON” or “SOUND OFF” and press 
the [ARM/DISARM] button to accept.  

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Programming the Voice Dialer, continued: 

Example 2

 – To store a number with area code 1-949-555-1234, and an office extension #200 

(where the called number requires a 2-second pause before the extension): After scrolling to 
the desired number location, enter ‘19495551234,’ press the [DEL/PAUSE] button for 2 
seconds until ‘F’ appears on the LCD screen, press the [#/DOWN] button for 2 seconds until 
the ‘

’ appears on the LCD screen, enter ‘200,’ and press the [ARM/DISARM] button. 

Example 3

 – To store a local number 555-2858: After scrolling to the desired number location, 

enter ‘5552858’ and press the [ARM/DISARM] button. 

5.

 

Repeat for the other numbers to be stored (up to 5 total). 

6.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

 

Note:

 

If the dialer is programmed to call a voice pager service which requires operator assistance, the 

service should be notified in advance regarding the meaning of the message. Consult local authorities 
concerning the permissibility of automatically dialing their emergency numbers before programming.

 

Содержание E-921CPQ

Страница 1: ...dialed at each stage of the dialing process The receiver can then listen in or broadcast a message to the room occupants or can disarm the system The same functions are available by remote call in as...

Страница 2: ...tery not included Wall mountable Built in 105dB alarm with programmable alarm on off Built in auxiliary output for external alarm or siren Built in line seizure Table of Contents Features 2 Parts List...

Страница 3: ...mergency phone numbers 5 Maximum digits per telephone number 32 Backup battery type life not included 9VDC 20h Alarm sound level at 12 30cm 105dB Trigger inputs Triggers 1 and 2 NO NC Trigger auto det...

Страница 4: ...ease see Programming the Voice Dialer on pages 6 9 Installing the Voice Dialer Siren Alarm Auto Dial Call Back Rings Home Mode Activated Alarm Triggered Time Date PASSWORD MEMORY LEARN CYCLE ENTRY 201...

Страница 5: ...outputs of a separate alarm system When Trigger 3 is used the jumper connection to ground must be removed 6 Power a If the dialer is to be powered from the alarm control panel connect the alarm power...

Страница 6: ...PIN number is forgotten press and hold the PROG button and use a pen or paper clip to press the RESET button located near the battery receptacle cover on the back of the unit and release The unit will...

Страница 7: ...to select other setup categories or press the PROG button until the programming icons disappear to exit the setup mode Programming the Voice Dialer continued Example 2 To store a number with area cod...

Страница 8: ...s 3 cycles meaning that the voice dialer will dial each programmed number 3 times 1 Enter the PIN number and press the PROG button six times or until CYCLE flashes on the LCD screen 2 Press the ARM DI...

Страница 9: ...LCD screen as 5 sets of numbers representing the year month date hour and minute respectively The first set of numbers year will be flashing indicating that this can now be changed 4 Press the DOWN or...

Страница 10: ...e that exit delay time has passed and the alarm is now fully armed During the 60 second delay time after the system is armed if the system detects trigger 3 indicating an open door or window a beep to...

Страница 11: ...by Telephone The system can be remotely controlled and monitored through any Touch Tone phone including mobile phones The user may either arm or disarm the system listen in on any activity in the room...

Страница 12: ...such as 1 Room Monitor will end broadcasting and perform the other related function If there is no other key press the call will disconnect at the end of the 50 seconds Note Alternating between Listen...

Страница 13: ...cator When the charge level of the 9VDC backup battery not included is low the LOW BATT LED will flash once every 1 5 seconds Replace the battery in order to continue providing functionality during a...

Страница 14: ...to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed 5 If this equipment US 7M7TE02BE921CPQ causes harm to the telephone network the telephone company...

Страница 15: ...Setting the Date Time see pg 9 PIN PROG x9 ARM DISARM DOWN or UP ARM DISARM Repeat for each position PROG x2 10 Record Emergency Message see pg 9 11 Playback Message see pg 9 PIN REC PLAY Speak messag...

Страница 16: ...Inc 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com Phone 949 261 2999 800 662 0800 Email sales seco larm com IMPORTANT Users and installers of this product are responsible for ensuri...

Отзывы: