background image

ENFORCER Auto Dialer 

8

 

SECO-LARM U.S.A., Inc. 

 

 

Note: 

1.

 

When the dialer is in standby mode and the (

) icon is ON, the auto dial is disabled.  

2.

 

When the dialer is in standby mode and the (

) icon is OFF, the auto dial is enabled. 

Setting the Auto Dial Function  

The user can choose whether or not the dialer will dial the emergency numbers when triggered. 
The factory default is “ON”. 

1.

 

Enter the PIN number and press the [PROG] button five times or until the phone icon (

flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept.  

3.

 

Press the [#/DOWN] or [*/UP] button to select either “ON” or “OFF” and press the 
[ARM/DISARM] button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Programming the Auto Dialer, continued: 

Setting the Number of Auto Dial Cycles 

This can be set from 1~5 cycles. The factory default is 1 cycle, meaning that the auto dialer will 
dial each programmed number 1 time.  

1.

 

Enter the PIN number and press the [PROG] button six times or until “CYCLE” flashes on the 
LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select your choice of 1-5 cycles and press the 
[ARM/DISARM] button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Setting the Number of Call-in Rings 

This sets the number of call-in rings after which the auto dialer will answer. The factory default is  
5 rings, but can be user programmed for 3, 5, 7, or 10 rings. 

1.

 

Enter the PIN number and press the [PROG] button seven times or until the bell icon ( ) 
flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select 3, 5, 7, or 10 and press the [ARM/DISARM] 
button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

 

ENFORCER Auto Dialer  

SECO-LARM U.S.A., Inc. 

9

 

 

Setting the Entry Delay Time 

This allows the user to set the length of time before the alarm will sound, to allow time to disable 
the alarm after normal entry. The factory default is 20 seconds, but can be user programmed for 0, 
5, 10, 15, or 20 seconds. 

1.

 

Enter the PIN number and press the [PROG] button eight times or until “ENTRY” flashes on 
the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

Press the [#/DOWN] or [*/UP] button to select 0, 5, 10, 15, or 20 seconds and press the 
[ARM/DISARM] button to accept. The dialer will “beep” once. 

4.

 

Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 
button until the programming icons disappear to exit the setup mode. 

Setting the Date and Time 

1.

 

Enter the PIN number and press the [PROG] button nine times or until the clock icon (

flashes on the LCD screen. 

2.

 

Press the [ARM/DISARM] button to accept. 

3.

 

The date and time will appear on the LCD screen as 5 sets of numbers representing the year, 
month, date, hour, and minute respectively. The first set of numbers (year) will be flashing, 
indicating that this can now be changed.  

4.

 

Press the [#/DOWN] or [*/UP] button to select the correct number for the year and press the 
[ARM/DISARM] button to accept and move to the next position. Repeat for each position until 
complete. 

5.

 

Press the [PROG] button until the programming icons disappear to exit the setup mode. 

Note: 

Time is shown using a 24 hour clock. 

Programming the Auto Dialer, continued: 

Testing the Auto Dial Function: 

To test the auto dial function, while in standby mode, press and hold the [PROG] button for at least 
two seconds. When you hear a ‘beep’ tone, enter the memory location (1~5) of the number you 
wish to test. The auto dialer should then dial the chosen number.  

Resetting the Auto Dialer: 

To reset the Auto Dialer, press and hold the [PROG] button and use a pen or paper clip to press 
the [RESET] button located under the cable cover on the back of the unit and release. The unit will 
return to the factory preset PIN number (000). All other user programmed settings except the date 
and time will be retained. 

Содержание E-921APQ

Страница 1: ...trical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a...

Страница 2: ...Button Use 10 Remote Control by Telephone 11 12 Home Mode Use 12 Low Battery Indicator 13 View Function 13 Tips 13 Also Available from SECO LARM 13 Program Planner 14 Summary Programming Operation Ch...

Страница 3: ...arm Siren Power Adapter 3 5mm Phone Plug Not Included External Power Supply SM 206Q E 964 D390Q E 964 D390Q Photobeam Detectors SM 200Q Magnetic Sensors and SM 206Q Concealed Magnetic Sensors shown as...

Страница 4: ...Photobeam Sensor E 931 S35RRQ Operating the Auto Dialer continued Low Battery LOW BATT Indicator When the charge level of the 9VDC backup battery not included is low the LOW BATT LED will flash once e...

Страница 5: ...EEPROM to retain memory in the event of a power loss 1 Select a location for the dialer near a standard electrical outlet if user supplied 12VDC adapter is to be used a telephone wall jack and the ala...

Страница 6: ...usual A or can also be entered by pressing and holding for two seconds the DOWN or UP buttons respectively The sign shows as and the sign shows as on the LCD screen ENFORCER Auto Dialer SECO LARM U S...

Страница 7: ...d Phone Number 1 Enter the PIN number and press the PROG button twice or until MEMORY flashes on the LCD screen 2 Press the ARM DISARM button to accept 3 Press the DOWN or UP button to select the numb...

Страница 8: ...ss the PROG button until the programming icons disappear to exit the setup mode ENFORCER Auto Dialer SECO LARM U S A Inc 9 Setting the Entry Delay Time This allows the user to set the length of time b...

Отзывы: