8
MODEL: EWC12-148
USER’S MANUAL
Distribué par
|
Distributed by:
Trans-Canada
Energies
700, chemin du Grand Bernier Nord
Saint-Jean-sur-Richelieu
(Québec) J2W 2H1
Phone/Téléphone: 450 348-8720
Toll free/Sans frais: 1 800-661-3330
FABRIQUÉ EN CHINE - MADE IN CHINA
MAINTENANCE
The charger is maintenance free. If the power cord is damaged, the charger must be left to the reseller for maintenance.
The case should be cleaned occasionally. The charger should be disconnected from the power while cleaning.
1 YEAR PRODUCT WARRANTY
The charger is substantially free from defects in material and workmanship under normal use for a period of 1 year
from the date of purchase.
TROUBLE SHOOTING
TYPES OF
PROBLEMS
INDICATION POSSIBLE CAUSES
SUGGESTED SOLUTION
Charger does not work?
No Indicator
lights on.
No AC power
Check AC connections and make sure Power
is switched ON.
Charger has no DC output?
Fault RED LED
is ON.
- Output is short circuited
- Reverse polarity
connection to Battery
- Check DC connection between charger and battery
and make sure they are not short circuiting.
- Check that the crocodile clips haven’t fallen
off the battery.
- Check that the crocodile clips / ring terminals
are connected to the correct polarity.
No Charging Current?
Fault RED LED
is Flashing.
- Battery is severely
sulphated
- Battery has a damaged cell
- Overheat protection mode
- Check the Battery condition, age, etc.
- Battery may need replacement.
- Move battery & Charger to cooler environment.
Full / Float light
won’t come on?
Fault RED LED is
Flashing.
Or Full LED is
Flashing.
- Battery capacity too large
for the battery charge and
it has timed out.
- Battery is defective
- Battery is severely
sulphated.
- Check the charger specification matches
the battery capacity.
- Battery cannot be charged and must be replaced.
- Charge rate selected might be too low, switch
charger off and on and try a higher charge rate
setting providing it doesn’t exceed the maximum
charge limit for your battery.