4.3  Instruction of water level sensors

Tank  water  level  sensor:

  The  tank  water  level  senor  is  used  to  detect  the  water  level  of 

tank.Once the tank is full,the sensor will stop the system.When installation,connect“COM2”at 
the bottom of tank,connect“TH”at the top of tank.Once the water level is full,the system will 
stop in 8s;once the tank is empty,the system will re-start to work in 5mins.

4.4  Light Instruction

Table 4  150V/220V/300V Light Instruction

Lighting

Light Situation

Light Situation Instruction

Recover 

Time

150V

220V

300V

POWER

Stay On

System Normal

MPPT

Flashing

MPPT mode on

ERR_I

Stay On

T≥15S

I≥15A;    

T≥15min

Flashing

I≥32A.

Stay On

A:Vsolar≤50V      
B

I≤1.3A.   

A:Vsolar≤110V      
B

I≤1.3A.  

A:Vsolar≤220V      
B

I≤1.3A.   

T≥6min

Flashing

Vsolar≥250V  Vsolar≥350V   Vsolar≥450V  

Tank_F

Stay On

The tank is full

Flashing

Wait for pumping up

T≥5min

WELL_L

Stay On

No water in the well

Flashing

Wait for pumping up

T≥30min

AN

-

Meaningless for Now

Well  water  level  sensor:

  The  well  water  level  sensor  is  used  to  detect  the  water  level  of 

well.Once  the  well  is  empty,  the  sensor  will  stop  the  system  .When  installaiton,connect 
“COM1”at  the  bottom  of  well,connect“WH”  higher  than  “COM1”.Once  the  well  is  empty,the 
system will stop in 10s; once the water level is higher than “WH”level,the system will re-start 
to work in 30mins.

5.Operating Board Instruction

5.1  Operating Board

C ha r t 2 O p e ra ting B o a rd

5 .2  B u tto n I ns tru ctio n

START   VAP     NEH    STOP

Ta b le 5 B u tto n F u nctio nh

Button

Instruction

“Start”

The pump will start running immediately, no 1min delay 
when power connecting any more 

“V/A/P“

Display the system parameters sequently, 
voltage/current/power

“n/E/h“

Display the system parameters sequently, speed/ fault 
code/system operate time

“Stop“

Stop the pump immediately, and the pump must be reboot 
manually 

07

08