Bentone B55/B65 RME
General
5. Inlet
Vacuum gauge port
7. To nozzle
8. Return
6. Pressure adjustment
Oil under suction
Oil under pressure
By passed oil returned to tank, or to suction
4. By-pass plug installed
3. Pressure gauge port
2. By-pass hole
1. Gear set
7.5
Function
The pump gear (1) draws oil through the pump suction port (5) from the tank
through the ilter in the pump and transports the oil to the valve (6) which
controls the oil pressure to the nozzle. Oil that does not go through the outlet
(7) to the nozzle will be bypassed (2) through the valve (6) back to the return
port (8) on the pump.
7.6
Preheating pump
The pump has the facility to it an immersion heater to providing preheating.