5. Use and conditions
5.1 The Truck iQ™ is a data display designed to be installed
on an industrial forklift truck. 2. The assembly must be
carried out with the battery disconnected.
5.2 Input voltages: 15 – 120VDC.
5.3 Temperature range: 0°C to 70°C.
5.4 Altitude: <2000m.
5.5 Pollution level protection: 3 dusty environments.
5.6 Technical support: refer to www.enersys.com to find your
local contact.
6. Buzzer
The Truck iQ is equipped with a sound buzzer. The buzzer will
warn the user to critical State of Charge battery.
SoC (State of Charge) Buzzer
Stop condition
Warning
3 bips every 30s
Normal SoC
Alert
3 bips every 5s
Normal SoC
7. Warning
The Truck iQ will display warnings:
ICON
Description
Stop condition
Warning
activated
Check on screen 1
High
temperature
Stop and cooldown the
battery
Low water level
Top up the battery
Cells unbalance
Stop, charge and
equalise the battery cells
Energy
throughput
too high
Stop, and cooldown the
battery
8. Warranty
Warranty is offered by the manufacturer based on local
regulations. Please contact your local distributor for further
information.
9. Information plate
10. Certifications
EnerSys hereby declares that the device conforms to
the descriptions laid down in European Directives:
• Directive 2014/30/EU:
Electromagnetic Compatibility
European standard:
- NF EN 12895: (2015-12)
• Directive 2014/35/EU:
Low Voltage Directive
European standard:
- EN 60950-1 : 2006 + A11:2009 + A1:2010 + A12:2011 +
A2:2013 - Information Technology Equipment –Safety
• Directive 2014/35/EU:
Radio Equipment
European standard:
- ETSI EN 301 489-1 V2.1.1 (2017-02)
- ETSI EN 301 489-17 V3.1.1 (2017-02)
- ETSI EN 300 328 V2.1.1 (2016-11)
www.enersys.com
Subject to technical modification without any prior notice. E.&O.E.
Publication No. EN-AC-TQ-IU-001 - 05.2019
Input:
15-120V/ 1W
Model No:
TR-100-1
S/N:
RZGA-12458D
THE ACCESSORY IS INTENDED FOR FIELD
INSTALLATION ONLY BY QUALIFIED PERSONNEL
Contains FCC ID: WAP2001
48 mm
16 mm