![EnerSys ODYSSEY EXTREME 25-PC1400 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/enersys/odyssey-extreme-25-pc1400/odyssey-extreme-25-pc1400_technical-manual_2411485006.webp)
Publication No: EN-ODY-TM-0002 - February 2015
www.odysseybattery.com
6
PC925 performance data at 25°C, per 12V module
W
atts or amps per 12V unit
10000
1000
100
10
1
Watts
Amps
0.01
0.1
1
10
100
Hours to 10.02V @ 25ºC
2 min
2381
224.8
7.5
79.3
615.8
20.5
201.8
6.7
5 min
1446
142.8
11.9
120.5
374.0
31.2
122.5
10.2
10 min
954
90.6
15.4
162.2
246.8
42.0
80.9
13.7
15 min
726
67.4
16.9
181.5
187.8
46.9
61.5
15.4
20 min
592
54.2
17.9
195.2
153.0
50.5
50.1
16.5
30 min
436
39.2
19.6
217.8
112.7
56.3
36.9
18.5
45 min
316
28.1
21.1
236.7
81.6
61.2
26.8
20.1
1 hr
250
21.9
21.9
249.6
64.6
64.6
21.2
21.2
2 hr
138
11.9
23.8
276.0
35.7
71.4
11.7
23.4
3 hr
96
8.3
24.9
288.0
24.8
74.5
8.1
24.4
4 hr
74
6.4
25.6
297.6
19.2
77.0
6.3
25.2
5 hr
61
5.2
26.0
303.0
15.7
78.4
5.1
25.7
8 hr
40
3.4
27.2
316.8
10.2
81.9
3.4
26.9
10 hr
32
2.8
27.5
324.0
8.4
83.8
2.8
27.5
20 hr
17
1.5
30.0
348.0
4.5
90.0
1.5
29.5
Time
Watts
Amps
Capacity Energy
(W)
(A)
(Ah)
(Wh)
W/liter
Wh/liter
W/kg
Wh/kg
ENERGY AND POWER DENSITIES
PC680 performance data at 25°C, per 12V module
W
atts or amps per 12V unit
10000
1000
100
10
1
0.1
Watts
Amps
Hours to 10.02V @ 25ºC
0.01
0.1
1
10
100
2 min
1486
143.0
4.8
49.5
601.4
20.0
212.3
7.1
5 min
792
78.8
6.6
66.0
320.5
26.7
113.1
9.4
10 min
512
49.3
8.4
87.1
207.3
35.3
73.2
12.4
15 min
389
36.7
9.2
97.4
157.6
39.4
55.6
13.9
20 min
318
29.6
9.8
104.9
128.7
42.5
45.4
15.0
30 min
236
21.6
10.8
118.2
95.7
47.8
33.8
16.9
45 min
173
15.6
11.7
130.1
70.2
52.6
24.8
18.6
1 hr
138
12.3
12.3
138.0
55.8
55.8
19.7
19.7
2 hr
79
6.9
13.8
157.2
31.8
63.6
11.2
22.5
3 hr
56
4.8
14.4
166.5
22.5
67.4
7.9
23.8
4 hr
43
3.7
14.8
172.8
17.5
69.9
6.2
24.7
5 hr
35
3.0
15.0
177.0
14.3
71.6
5.1
25.3
8 hr
23
2.0
16.0
187.2
9.5
75.8
3.3
26.7
10 hr
19
1.6
16.0
192.0
7.8
77.7
2.7
27.4
20 hr
10
0.8
16.0
204.0
4.1
82.6
1.5
29.1
Time
Watts
Amps
Capacity Energy
(W)
(A)
(Ah)
(Wh)
W/liter
Wh/liter
W/kg
Wh/kg
ENERGY AND POWER DENSITIES
1
10
100
1000
10000
W
atts or amps per 12
V
unit
Hours to 10.02V @ 25ºC
0.01
0.1
1
10
100
Watts
Amps
PC950 performance data at 25°C, per 12V module
Time
Watts
(W)
Amps
(A)
Capacity
(Ah)
Energy
(Wh)
ENERGY AND POWER DENSITIES
W/litre
Wh/litre
W/kg
Wh/kg
2 min
2794
268.3
8.9
93.1
755.0
25.2
310.4
10.3
5 min
1745
161.3
13.4
145.4
471.6
39.3
193.9
16.2
10 min
1126
101.4
16.9
187.7
304.4
50.7
125.1
20.9
15 min
848
75.3
18.8
212.0
229.1
57.3
94.2
23.6
20 min
686
60.3
20.1
228.6
185.4
61.8
76.2
25.4
30 min
502
43.6
21.8
250.8
135.6
67.8
55.7
27.9
45 min
362
31.1
23.3
271.4
97.8
73.3
40.2
30.2
1 hr
284
24.3
24.3
284.4
76.9
76.9
31.6
31.6
2 hr
157
13.2
26.4
313.2
42.3
84.6
17.4
34.8
3 hr
110
9.2
27.6
329.4
29.7
89.0
12.2
36.6
4 hr
85
7.1
28.4
338.4
22.9
91.5
9.4
37.6
5 hr
70
5.8
29.0
348.0
18.8
94.1
7.7
38.7
8 hr
46
3.8
30.4
364.8
12.3
98.6
5.1
40.5
10 hr
37
3.2
32.0
372.0
10.1
100.5
4.1
41.3
20 hr
20
1.7
34.0
408.0
5.5
110.3
2.3
45.3