7.0 Installation, continued
76
704-939-B10-001 Rev. A5 (06/2019)
7.6.8 Connecting the Battery Heater Mat Controller
Power to the heater mat is provided via a customer-supplied controller plugged into the power outlet inside the enclosure.
A cable (Alpha p/n 875-627-22) connects the controller to the ENV (Environmental) connector on the transponder. The
connection procedure is shown below.
Once the connection has been made, Environmental Control Management can be configured using an SNMP MIB
browser as indicated in the following tables. The Environmental Control MIB section begins at atiMgmtSysTempMgr
(1.3.6.1.4.1.926.1.3.2.4). Status of the Environmental Control is also available via the Communications Module’s Web
page by navigating to ‘Advanced Configuration’, ‘I/O – Environment’. Ensure the ‘Heater/Cooler Only’ is selected from the
drop-down list.
Connect the 4-pin
connector from the
controller cable
into the base of the
Heater Mat Controller.
Plug the controller
into the power outlet.
Plug the 10-pin
connector into the
ENV connector.
Plug the Heater Mat into the controller.
ENV
ALM/
RDY
TPR
RST