Enerpac P-391, 1004 Скачать руководство пользователя страница 3

3

■ 

Troubleshooting Guide

IMPORTANT: 

To remove system variables and isolate pump for testing, connect test circuit of a known

good hose, a 0-15,000 psi gauge, and a 10 ton single-acting cylinder to the pump.

To protect warranties, use only Enerpac Hydraulic Oil.

Problem

Pump does not hold pressure

Pump loses pressure and the
handle rises.

Pump does not build pressure.

Pump does not create flow.

Probable Cause

Leak in the release check.

Leaking at hose and/or coupler
connection.

Outlet check seat leaking.

Inlet check balls leaking.

Damaged seals on the pump
plunger.

Oil filter screen clogged with
debris.

Relief setting too low or leaking
valve gasket.  

Low or no oil in reservoir.

Debris in pump.

Pump not vented.

Coupler checked.

Low or no oil in reservoir.

Remedy

Inspect and clean ball and
seat. Reseat check ball.

Check for leak. Reseal with
appropriate sealant.

Inspect and clean ball and
check seat. Reseat check ball.

Inspect spring ball and seat.
Reseat check ball.

Inspect and replace seals if
necessary.

Flush pump, replace oil and
screen.

Inspect valve, check pressure
setting, and replace gasket.

Fill reservoir with Enerpac oil. 

Inspect all components for
contamination, then flush.

Open vent cap.

Correctly couple together.

Fill reservoir with Enerpac oil.

Содержание P-391, 1004

Страница 1: ...ir gasket and tie rod from the pump base 2 Remove handle and plunger assembly a Remove plunger cross pin and plunger clip Remove handle assembly from the base Note Older solid plungers have a plunger...

Страница 2: ...chain through reservoir fill port Loop chain around the tie rod and thread tie rod into pump base b Replace end cap gasket and put end cap onto end of reservoir c Using new copper gasket tighten the...

Страница 3: ...king Damaged seals on the pump plunger Oil filter screen clogged with debris Relief setting too low or leaking valve gasket Low or no oil in reservoir Debris in pump Pump not vented Coupler checked Lo...

Страница 4: ...an Sea Countries ENERPAC Applied Power GmbH P O Box 300113 D 40401 D sseldorf Germany Tel 49 211 471 490 Fax 49 211 471 49 28 India ENERPAC Hydraulics India Pvt Ltd Plot No A 571 MIDC TTC Industrial A...

Страница 5: ...ensembles levier et piston a Enlever l axe transversal et le clip du piston Enlever l ensemble levier de la base Note Les anciens pistons en une pi ce poss dent un clip de piston et un axe transversa...

Страница 6: ...ler un nouveau joint torique en positionnant le r servoir sur la base de la pompe S assurer que le r servoir se trouve plac correctement sur l ergot de positionnement a Passer la cha ne de l assemblag...

Страница 7: ...til e Raccord rapide obtur Pas d huile ou niveau d huile trop bas dans le r servoir Rem de V rifier et nettoyer la bille et le si ge Rectifier le si ge Rechercher une fuite ventuelle Utiliser un produ...

Страница 8: ...ndustrial Area Mahape 400 701 Navi Mumbai India T l 91 22 2778 1472 Fax 91 22 2778 1473 Italie ENERPAC S p A Via Canova 4 20094 Corsico Milano T l 39 02 486 1111 Fax 39 02 4860 1288 Japon Applied Powe...

Отзывы: