3.0 DESCRIPTION

Selected Enerpac Collet-Lok

 ®

 swing clamps, work 

supports and push cylinders include lower mounting 

flanges that can be used with manifold porting.
To mount the Collet-Lok

 ®

 product on a fixture using the 

manifold ports:

1.  Prepare the fixture plate so that the internal passages 

are located to intersect with the manifold ports on the 

mounting flange of the 

Collet-Lok

 ® 

 product. Refer to 

Section 4.0.

2.  Leave the plugs installed in the tubing ports on the 

Collet-Lok 

®

 product. These plugs must remain in 

place when the manifold ports are used.

3. Remove the port screw and copper gasket from 

each manifold port on the underside of the mounting 

flange.

4. Install the supplied o-rings in the manifold ports 

before installing the 

Collet-Lok

 ®

 product on the 

fixture plate. Follow the specifications for plate 

surface finish and flatness shown in Figure 1.

4.0 MOUNTING DIMENSIONS

To ensure proper operation, the internal passages in the 

fixture plate must be precisely aligned with the manifold 

ports located on the underside of the Collet-Lok 

®

 

mounting flange. Mounting bolt holes must also be in 

precise alignment and of the proper size. For additional 

information, refer to Table 1 and figures 2 through 9.

Note:

 Figures 2 through 9 are provided only to show 

mounting dimensions and port locations. The diagrams 

are not drawn to scale. All figures show the TOP side of 

the fixture plate, as viewed from above.

Figure 1, Manifold Mounting Details, Collet-Lok

 ® 

Products Equipped With Manifold Ports

IMPORTANT: DO NOT REMOVE PLUGS! 

All plugs must remain installed when 

manifold ports are used.

PORT SCREW AND 

COPPER GASKET 

(REMOVE)

MANIFOLD O-RING 

(INSTALL)

MOUNTING 

FLANGE

MANIFOLD O-RING 

(INSTALLED IN PORT)

ø0.190 [ø4,83mm]

Содержание MPFL-50V

Страница 1: ...from cylinder and workpiece during operation WARNING Never set the relief valve to a higher pressure than the maximum rated pressure of the pump Higher settings may result in equipment damage and or...

Страница 2: ...on the fixture plate Follow the specifications for plate surface finish and flatness shown in Figure 1 4 0 MOUNTING DIMENSIONS To ensure proper operation the internal passages in the fixture plate mu...

Страница 3: ...MFPN 300V MPFR 300V WPFL 300V WFPN 300V WPFR 300V 4 Collet Lok Work Supports MPFS 100V WPFS 100V 5 MPFS 200V WPFS 200V 6 MPFS 450V WPFS 450V 7 Collet Lok Push Cylinders MPFC 110V WPFC 110V 8 MPFC 210V...

Страница 4: ...FLANGE REF 6X 5 16 18 TAP X 0 62 DP IMPERIAL M8 X 1 25 X 16 0mm DP METRIC 2X 1 604 40 75mm 0 802 20 37mm 2X 1 604 40 75mm 2X 0 926 23 53mm 1 852 47 05mm Figure 6 Mounting Dimensions Models MPFS 200V...

Страница 5: ...X 1 434 36 42mm 1 656 42 05mm 1 656 42 05mm 0 956 24 29mm 0 956 24 29mm 3X 0 190 4 83mm MAX TO DESIRED DEPTH 2X 0 828 21 03mm 1 193 30 31mm Figure 9 Mounting Dimensions Models MPFC 210V WPFC 210V 3X 0...

Страница 6: ...rial Straight Flange Body Viton Seals MPFL300V Swing Clamp Metric Left Hand Flange Body Viton Seals MPFR300V Swing Clamp Metric Right Hand Flange Body Viton Seals MPFN300V Swing Clamp Metric Straight...

Страница 7: ...Notes...

Страница 8: ...les ru enerpac com and Taiwan Actuant Asia Pte Ltd 83 Joo Koon Circle Singapore 629109 T 65 68 63 0611 F 65 64 84 5669 Toll Free 1800 363 7722 sales sg enerpac com South Korea Actuant Korea Ltd 3Ba 71...

Отзывы: