Enerpac LW16 Скачать руководство пользователя страница 11

11

Table 1 - Troubleshooting Guide, Model LW-16

Problem

Possible Cause

Solution

1.  Lifting wedge will not 

advance.

a.  Load too heavy for lifting wedge.

Reduce load or use a larger capacity lifting device.

b.  Pump release valve open.

Close pump release valve.

c.  Coupler not fully tightened.

Tighten coupler.

d.  Pump malfunctioning.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

2.  Lifting wedge advances 

only part way.

a.  Low oil level.

Add oil to reservoir.

b.  Coupler not fully tightened.

Tighten coupler.

c.  Cylinder plunger binding or 

damaged.

Repair or replace component(s) as required. Contact 

Enerpac Authorized Service Center.

3.  Lifting wedge advances 

in spurts.

a.  Air in hydraulic system.

Purge air from system. Refer to Section 6.5.

b.  Cylinder plunger binding or 

damaged.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

4.  Lifting wedge advances 

slower than normal.

a.  Coupler not fully tightened.

Tighten coupler.

b.  Leaking connection.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

c.  Pump malfunctioning.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

5.  Lifting wedge advances 

but will not hold.

a.  Leaking connection.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

b.  Cylinder seals leaking.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

c.  Pump malfunctioning.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

6.  Lifting wedge cylinder 

leaks oil.

a.  Loose connection.

Tighten coupler.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

b.  Cylinder seals worn or damaged.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

c.  Cylinder has internal damage.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

7.  Lifting wedge will 

not retract or retracts 

slower than normal.

a.  Pump release valve is closed.

Open pump release valve.

b.  Coupler not fully tightened.

Tighten coupler.

c.  Pump reservoir overfilled.

Drain excess oil from reservoir.

d.  Narrow hose restricting flow.

Replace hydraulic hose with hose of larger diameter.

e.  Broken or weak cylinder retraction 

spring.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

f.  Cylinder and/or wedge mechanical 

components worn or damaged.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

8.  Oil leaking from external 

relief valve.

a.  Coupler not fully tightened.

Tighten coupler.

b.  Restriction in hydraulic hose.

Remove restriction.

c.  Cylinder has internal damage.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

9.  Lifting wedge advances 

normally but does not 

retract under load.

 

Driven wedge needs lubrication.

Remove lifting wedge from load and lubricate driven 

wedge.

10.  Lifting jaw is bent.

a.  Load shift.

Reposition load to prevent load shift.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

b.  Load too heavy for lifting wedge.

Reduce load or use a larger capacity lifting device.

Repair or replace component(s) as required.

Contact Enerpac Authorized Service Center.

11.  Lifting wedge advances 

halfway and then stops.

 

Pump reservoir not vented.

Open reservoir air vent.

Содержание LW16

Страница 1: ...derate personal injury NOTICE Indicates information considered important but not hazard related e g messages relating to property damage Please note that the Safety Alert Symbol will not be used with this signal word 1 2 Safety Precautions Hydraulic Vertical Lifting Wedges WARNING Failure to observe and comply with the following precautions and instructions may result in death or serious personal ...

Страница 2: ... a controlled rate Closely watch the load at all times during lifting and lowering Stop lifting or lowering immediately if the load becomes unstable or appears to be lifting or lowering unevenly Stay clear of loads supported only by hydraulics Follow the lifted load with the Enerpac SB 2 safety block or use suitable cribbing Conduct a risk assessment prior to performing any lift Always be certain ...

Страница 3: ...ing wedge pressurized hose and load during operation NOTICE Ensure that any repairs are performed only by trained qualified and authorized personnel using original equipment replacement parts For repair service contact the Enerpac Authorized Service Center in your area 1 5 Additional Safety References Consult the applicable industry and or government standards in your country or region for additio...

Страница 4: ...17 80 7 C 0 93 23 5 I 2 68 68 0 D 0 65 16 5 J 4 33 110 0 E 0 39 10 0 K 5 50 140 0 F L 8 27 210 0 3 3 Dimensions Model LW 16 Lifting Wedge extended position I J K L A B C D E F G H Item Imperial in Metric mm Item Imperial in Metric mm A 4 76 121 0 G 9 72 247 0 B 2 03 51 5 H 3 17 80 7 C 1 75 44 5 I 2 68 68 0 D 1 48 37 5 J 4 33 110 0 E 1 20 30 5 K 5 50 140 0 F 1 77 45 0 L 8 27 210 0 ...

Страница 5: ...0 30 5 H 9 97 253 2 C 0 93 23 5 I 4 33 110 0 D 0 65 16 5 J 14 92 378 9 E 0 39 10 0 K 2 68 68 0 F 3 5 Dimensions Model LWC 16 Lifting Wedge extended position A B C D E F G H I K J Item Imperial in Metric mm Item Imperial in Metric mm A 4 76 121 0 G 9 72 247 0 B 2 03 51 5 H 9 97 253 2 C 1 75 44 5 I 4 33 110 0 D 1 48 37 5 J 14 92 378 9 E 1 20 30 5 K 2 68 68 0 F 1 77 45 0 ...

Страница 6: ...ric mm Item Imperial in Metric mm A 2 17 55 0 F 0 79 20 0 B 1 89 48 0 G 4 00 101 6 C 1 61 41 0 H 5 54 140 7 D 1 34 34 0 I 1 50 38 0 E 1 06 27 0 3 7 Dimensions Model LWB 1 Stepped Block E A B C D Item Imperial in Metric mm A 1 51 38 3 B 1 18 30 0 C 1 26 32 1 D 1 25 31 7 E 2 62 66 5 ...

Страница 7: ...uthorized Service Center NOTICE Failure to use the correct oil type may result in damage to hydraulic components and will void the product warranty Be sure that the oil is clean The oil cleanliness should be maintained to a maximum level of 18 16 13 per the ISO 4406 standard If the oil develops a milky cloudy or dark appearance it should be changed immediately To avoid overfilling and possible equ...

Страница 8: ...ins a series of steps The step to be used must be fully inserted into the access gap so that the heel of the step is in contact with the outer surface of the item to be lifted Refer to Figure 3 Figure 3 Inserting Wedge Under Load OK 5 Close the release valve on the hand pump and advance the wedge by operating the hand pump lever 6 When the item has been lifted to the desired height or to the maxim...

Страница 9: ...ped Block Accessory The LWB 1 stepped block is useful when lifting items containing a larger access gap It allows the item to be lifted higher and with less penetration The stepped block is included with the LWC 16 lifting wedge and available as an optional accessory for the LW 16 lifting wedge WARNING Failure to observe and comply with the following instructions could allow the load to become uns...

Страница 10: ...grease port 9 2 Alternate Lubrication Method all models if grease gun is not available 1 Connect hydraulic hose and hand pump to the lifting wedge Model LW 16 only 2 Close the pump release valve 3 Operate the pump lever to advance the wedge 4 Smear grease onto the exposed surfaces of the driven wedge 5 Open the pump release valve to retract the wedge 9 3 Guide Pin Lubrication To lubricate the guid...

Страница 11: ... a Loose connection Tighten coupler Repair or replace component s as required Contact Enerpac Authorized Service Center b Cylinder seals worn or damaged Repair or replace component s as required Contact Enerpac Authorized Service Center c Cylinder has internal damage Repair or replace component s as required Contact Enerpac Authorized Service Center 7 Lifting wedge will not retract or retracts slo...

Страница 12: ...inder leaks oil a Worn or damaged seals Repair or replace component s as required Contact Enerpac Authorized Service Center b Cylinder has internal damage Repair or replace component s as required Contact Enerpac Authorized Service Center 7 Lifting wedge will not retract or retracts slower than normal a Pump release valve is closed Open pump release valve Repair or replace component s as required ...

Страница 13: ...Notes 13 ...

Страница 14: ...Notes 14 ...

Страница 15: ...Notes 15 ...

Страница 16: ...POWERFUL SOLUTIONS GLOBAL FORCE http www enerpac com ...

Отзывы: