Enerpac BV5 Скачать руководство пользователя страница 4

4

Verify that there will be adequate clearance, so that 
the vise jaw can be fully extended to its maximum 
8 inch [203 mm] opening without contacting other 
objects. Also, verify that there will be suffi cient room 
to rotate the vise on the swivel base.

The vise is intended primarily for horizontal mounting, 
However, if desired, the vise can also be mounted 
vertically.

4.3  Vise Installation

Install the vise as described in the following steps:

1.  Assemble the vise to the swivel base as shown in 

Figure 3. Tighten the locking nuts hand tight.

2.  Route the hydraulic hose through the 1.5 inch 

[38,1 mm] diameter hole in the support surface.

IMPORTANT:

 One end of the hose is connected to 

the vise at the factory prior to shipment. To prevent air 
entry, do not disconnect the hose from the vise.

3.  Firmly secure the vise and swivel base to the 

support surface as an assembly. Use three 39/64" 
bolts (user-supplied).

4.  Rotate the vise to the desired position on the 

swivel base. To change vise position, loosen each 
locking nut about one full turn and rotate the vise 
to the desired position. After making adjustments, 
retighten the locking nuts to secure the vise.

4.4  Hydraulic Connections

Refer to Figure 4 for hydraulic connection diagrams.

A 10,000 PSI [700 bar] rated thermoplastic hydraulic 
hose is supplied with the vise. 

The hose end contains an Enerpac CH-604 male 
quick-disconnect coupler.

A female quick-disconnect coupler (Enerpac CR-400 
or equivalent) must be installed in the pump hydraulic 
outlet.

If the pump is not equipped with a gauge, install a 
0-10,000 PSI [0-700 bar] hydraulic pressure gauge 
between the pump outlet and the hydraulic hose.

IMPORTANT:

 Be sure that all couplers are properly 

connected. Loose or partially connected couplers will 
block the fl ow of oil between the pump and the vise.

5.0  OPERATION

WARNING:

 Read and understand the 

precautions contained in Section 3.0, 

Hydraulic Vise Operating Safety,

 before 

operating the vise. Failure to observe the precautions 
in Section 3.0 may result in serious personal injury or 
death.

Note: 

On vented pumps, be sure that the vent/fi ll cap 

is in the “vent” position to allow reservoir venting. If 
a vent screw or plug is used, be sure it is loosened 
(open).

Operate the vise as described in the following steps:

1.  To retract (close) the vise jaw, close the pump 

release valve and operate pump.

2. To lock (hold) the vise jaw in position, stop 

operating the pump, but keep the pump release 
valve closed.

3.  To extend (open) the vise jaw, 

slowly

 open the 

pump release valve.

Figure 4 - Hydraulic Connections (typical).

Key:

1.  Pressure Gauge
2.  Gauge Adapters
3.  Coupler, Female QD
4.  Hydraulic Hose
5.  Vise Assembly

2

*

3

*

4

1

*

5

*  

User supplied items
(not included with vise)

2

*

Hand Pump (typical)

Air-hydraulic Pump (typical) PA-133

Enerpac XA11G Pump

Отзывы: