background image

to hot wire, red lead to load wire, white lead to neutral wire, green lead

Occupancy Mode:

Best:180 sq.ft.

The coverage range of the sensor switch is specified and illustrated 

- 01-

-03-

-02-

DESCRIPTION

HMOS

HMOS

       

 

 OCCUPANCY / VACANCY

Voltage ..........................................................................  120VAC, 60Hz      

Incandescent ........................................................................…  500W

Motor  ...................................................................................……  1/8Hp        

Time Delay..............................................……  15 Sec, 15 Mins, 30 Mins  

SPECIFICATIONS

SENSOR SWITCH

(2-IN-1)

 

INSTALLATION

 Turn off the circuit breaker before installation.

WARNING:

Do not exceed electrical ratings.

3.  Gently position wires in wall box, attach sensor switch to the box.

2.  Device “TOP” upward.

4.  Restore power at circuit breaker or fuse, wait one minute.

INSTALLATION INSTRUCTIONS

Light Level...................................................................... Default setting

Indoor use only.

OCC  

Mode

VAC 

Description

after set time delay. 

Position

Upper side

Vacancy Mode: Manual On only, 

Automatic Off after set time delay.

Function of ON/OFF button

Manually push

Manually push

Automatic On, Automatic Off 

1. Connect lead wires as shown in wiring diagram (see Figure 2): Black lead

causing the light turns even though someone is still in the detection area.

The passive infrared sensor detects the difference between heat emitted

 from the human body in motion and the background space. The sensor

in Figure 1. Large object and some transparent barriers like glass 

windows will block some degrees of the sensor's view and prevent detection, 

Coverage Area

switch can turn a load on and hold it as long as the sensor detects 

 occupancy. After no motion is detected for the set time delay, the load turns

off automatically. 

On/Off the load.

On/Off the load.

to ground wire.

Operation Temperature.................................................... 32° F--131° F

Regular: 450 sq.ft.

Maximum: 700 sq.ft.

30'

Top View

15'

7.5'

15'

7.5'

15'

5'
4'

Lower side

ADJUSTMENT

5.  Locate the toggle switch on both sides of the top cover to perform

test and adjustment.

Default position

Adjustable

15 Seconds

15 Minutes

30 Minutes

15 Seconds (Test mode)

Neutral

White

Top

Hot

Black

Ground

Green

Neutral

-02-

White

Load

Red

Load

Figure 4

TOP

INDOOR
USE ONLY

Test

15 MIN

30 MIN

Test

15 MIN

30 MIN

VAC

OCC

VAC

OCC

Mounting Yoke

Fresnel Lens

LED Indicator

Control Top Cover

The switch ships with top cover attached. It is convenient for 

Push down top cover to release

OPEN

CLOSE

Line up tabs and push up to attach

Figure 2

Figure 1

Changing the color of your switch

Wiring diagram

1.

2.

Band switch prescription

Time delay setting

Figure 3

(ON/OFF Button)

Ambient light(Default setting)

 If the ambient light level is too high, more than the default setting,

the load may not automatic turned ON, If turning ON is desired, 

Notice:

 users to change the top cover. Please proceed as follows:

Resistive ............................................................................................ 5A   

Ballast........................................................................................500VA

cover the sensor lens with one hand for 2 seconds, the light is 
going to turn ON. 