background image

 
 

The Stream Engine® 

Easy Tune® Generator 

 
 
 

Owner’s Manual 

 
 

Please Read Carefully 

 
 
 
 

Made in North America 

 

By 

 
 

 

 

PO Box 4557 

Sussex NB 

Canada  E4E 5L7 

 

Phone +1 (506) 433-3151 
Fax     +1 (506) 433-6151 

Email: 

[email protected]

 

Website: 

www.microhydropower.com

 

 
 

The 

Stream Engine and Easy Tune 

are a Trademark of Energy Systems & Design Ltd. 

 

 

 

                                                                                                                                                       V1.0 7-2011

 

 
 

 
 

Содержание Easy Tune Stream Engine

Страница 1: ...Carefully Made in North America By PO Box 4557 Sussex NB Canada E4E 5L7 Phone 1 506 433 3151 Fax 1 506 433 6151 Email support microhydropower com Website www microhydropower com The Stream Engine and Easy Tune are a Trademark of Energy Systems Design Ltd V1 0 7 2011 ...

Страница 2: ...s Design Ltd if you run into trouble May your RE adventures prove successful Table of Contents Introduction 3 Site Evaluation 3 Head Measurement 3 Flow Measurement 4 Stream Engine Output in Watts Table 5 Intake Pipeline Tailrace 6 7 Batteries Inverters Controllers 7 8 Wiring and Load Center 8 9 Design Example 9 10 Output Adjustment 11 High Voltage 12 Determining Nozzle Size 12 Nozzle flow chart 13...

Страница 3: ...n be used on one machine to utilize heads as low as four feet and as high as hundreds SITE EVALUATION Certain information must be determined concerning your site in order to use its potential for maximum output Head and flow must first be determined Other factors are pipeline length transmission distance and the system voltage These factors determine how much power can be expected Power is generat...

Страница 4: ...ill flow over a weir one inch wide and from 1 8 to 10 7 8 inches deep Inches 1 8 1 4 3 8 1 2 5 8 3 4 7 8 0 0 0 0 1 0 4 0 7 1 0 1 4 1 9 2 4 1 3 0 3 5 4 1 4 8 5 5 6 1 6 9 7 6 2 8 5 9 2 10 1 10 9 11 8 12 7 13 6 14 6 3 15 5 16 5 17 5 18 6 19 5 20 6 21 7 22 8 4 23 9 25 1 26 2 27 4 28 5 29 7 31 0 32 2 5 33 4 34 7 36 0 37 3 38 5 39 9 41 2 42 6 6 43 9 45 3 46 8 48 2 49 5 51 0 52 4 53 9 7 55 4 56 8 58 3 59...

Страница 5: ...e amount of water must be left in the stream Don t take it all that water supports life forms When head and flow are determined the expected power output can be determined from the following chart Keep in mind that chart values represent generated output and that actual power delivered to the batteries will be reduced by transmission lines power converters and other equipment required by the syste...

Страница 6: ...uld be installed at a low point in the pipe For pipelines running over dams or in conditions that create a siphon the downstream side may be filled by hand Once filled the stop valve at the turbine can be opened to start the flow If full pressure is not developed or air builds up in the line a hand powered vacuum pump can be used to remove air trapped at the high point At the turbine end of the pi...

Страница 7: ...g water The diameter of the bolt holes is 6mm In cold climates it may be necessary to build a trap into the exit This prevents outside air from entering the housing and causing freeze ups BATTERIES INVERTERS CONTROLLERS System Voltage A small system with a short transmission distance can be designed to operate at 12 volts Larger systems can also be 12 volts but if higher power is desired or the tr...

Страница 8: ...oltage rises At some point the charging process should stop and the excess power be diverted to the dump load Most charge controllers permit different charge levels such as bulk absorption and float Literature supplied with the controller should be consulted to determine the set points of the charge controller Be sure to set the controller for hydro diversion Watt Hour meters are available that mo...

Страница 9: ...20 head 31 loss A flow of 30 gpm gives a net head of 102 3 feet 120 17 7 The losses caused by the various pipe fittings and intake screen will further decrease the dynamic head so 100 feet is a good working figure for the net head Looking at the nozzle flow chart we see that a 3 8 nozzle will produce a flow of 27 6 gpm at a head of 100 This is very close to the design point and the net head will b...

Страница 10: ...x 0 32 ohms 32 watts of loss Increasing the wire size further would reduce the losses Voltage drop in the wire is equal to IR 10 amps x 0 32 ohms 3 2 volts So if the battery voltage is 26 8 the generator will be operating at 30 0 volts Keep in mind that it is always the batteries that determine the system voltage That is all voltages in the system rise and fall according to the battery s state of ...

Страница 11: ...it With the meter set for 200 DC millivolts nine o clock position it will read directly in amps The DC output voltage can be read by setting the meter on the DC volts position 20 200 volts and using the black and white jacks as shown in the photo Once the meter is connected and the machine is operating the upper body of the machine is rotated slightly using the two big knobs on the sides of the ma...

Страница 12: ...ight be required by simply cutting the nozzle to the appropriate length Cutting can be done with a hacksaw or any other fine toothed saw The end of the nozzle should then be finished with a piece of sandpaper This is best done by placing the sandpaper on a flat surface and moving the nozzle against it Markings are on the nozzle to assist in cutting to the correct size The numbers are in millimeter...

Страница 13: ...7 6 49 1 76 7 111 150 196 2070 120 52 0 3 36 7 56 13 4 21 0 30 3 41 2 53 8 84 1 121 165 215 2270 150 65 0 3 76 8 95 15 0 23 5 33 8 46 0 60 1 93 9 135 184 241 2540 200 86 6 4 34 9 77 17 4 27 1 39 1 53 2 69 4 109 156 213 278 2930 250 108 4 86 10 9 19 9 30 3 43 6 59 4 77 6 121 175 238 311 3270 300 130 5 32 12 0 21 3 33 2 47 8 65 1 85 1 133 191 261 340 3591 400 173 6 14 13 8 24 5 38 3 55 2 75 2 98 2 1...

Страница 14: ... screws that are supplied with the machine These two screws are diameter and 2 long Tighten these evenly and fully and then the rotor can be removed BE CAREFUL The rotor is made with very strong magnets and will attract any iron or steel pieces that are near it Once the rotor is removed the lower bearing carrier can be removed by first removing the six screws on the outer edge of the carrier This ...

Страница 15: ...them once per year will help keep the area free of corrosion and make future bearing changes easier This machine uses two 6203 ball bearings with contact seals Copper Wire Resistance Chart Wire Gauge Diameter Inches Ohms per 1000 Ohms per Mile 0000 0 460 0 05 0 26 000 0 410 0 06 0 33 00 0 364 0 08 0 42 0 0 324 0 10 0 52 2 0 258 0 16 0 84 4 0 204 0 25 1 34 6 0 162 0 40 2 13 8 0 128 0 64 3 38 10 0 1...

Страница 16: ... 0 05 30 22 4 6 70 3 45 1 17 0 43 0 18 0 05 35 8 90 4 64 1 56 0 62 0 23 0 07 40 11 4 5 89 1 98 0 78 0 30 0 09 0 02 45 14 2 7 34 2 48 0 97 0 37 0 12 0 04 50 17 2 8 92 3 01 1 20 0 46 0 14 0 04 55 20 5 10 6 3 59 1 43 0 55 0 16 0 05 60 24 1 12 5 4 21 1 66 0 64 0 18 0 07 0 02 70 16 6 5 61 2 21 0 85 0 25 0 09 0 03 80 21 3 7 18 2 83 1 08 0 32 0 12 0 04 90 8 92 3 52 1 36 0 39 0 14 0 07 100 10 9 4 28 1 66 ...

Страница 17: ... 0 23 0 09 0 02 12 28 5 8 79 2 32 1 11 0 32 0 14 0 05 14 37 9 11 7 3 10 1 45 0 44 0 18 0 07 16 15 0 3 93 1 87 0 55 0 23 0 08 18 18 6 4 90 2 32 0 69 0 30 0 09 20 22 6 5 96 2 81 0 83 0 35 0 12 22 27 0 7 11 3 36 1 00 0 42 0 14 24 31 7 8 35 3 96 1 17 0 49 0 16 26 36 8 9 68 4 58 1 36 0 58 0 21 28 11 1 5 25 1 56 0 67 0 23 30 12 6 5 96 1 77 0 74 0 25 35 16 8 7 94 2 35 1 00 0 35 40 21 5 10 2 3 02 1 27 0 4...

Страница 18: ...fier There are three fuses one for each phase These fuses protect the internal wiring If the current goes over the safe limit a fuse may open If new fuses are needed always replace them with the exact type as supplied with the machine INTERNAL WIRING Inside the machine is additional wiring that determines the output voltage and current of the machine This can be connected in parallel to give lower...

Страница 19: ...hown in the photograph white blue and yellow wires are connected to one terminal screw and the black red and green wires are connected to the other screw This is repeated as shown around the terminal block until all of the connections are the same Parallel Series Series Wiring For series wiring the machine look at the shot of the shot that shows this You will see that for this scheme you will conn...

Страница 20: ...llation principles are the same for all Stream Engines from ESD A Stream Engine installed using PVC pipe and union valves Under construction a 30 head site shown before gravel base was added Installation with flexible pipe Note the pipe is attached to the nozzles using hose clamps ...

Страница 21: ...An installation of this sort will result in a huge loss of power To optimize the output of the generator all aspects of installation should be well done It is important to pay attention to plumbing nozzle size intake conditions siting electrical components as well as regular maintenance WRONG 90 bends in undersized line Do NOT install a stream engine in this manner WRONG Same undersized line for b...

Страница 22: ...Owner Notes ...

Страница 23: ..._______________________________ State Prov _________________ Zip Postal Code ______________ Telephone ______________________________________________ Email __________________________________________________ Comments ______________________________________________ ________________________________________________________ __________________________________________ Made in Canada By Energy Systems and D...

Отзывы: