Module-VAR-Variable-Speed-Heat-Pump-060118

Heating, Cooling and Indoor Air Quality Systems

www.hi-velocity.com

Installation and Operation

ESP

Variable Speed Heat Pump

3 Ton 

ESP-36

5 Ton 

ESP-60

Содержание ESP Series

Страница 1: ...Module VAR Variable Speed Heat Pump 060118 Heating Cooling and Indoor Air Quality Systems www hi velocity com Installation and Operation ESP Variable Speed Heat Pump 3 Ton ESP 36 5 Ton ESP 60 ...

Страница 2: ...and dumping excess air into part of the home This strategy wastes energy sacrifices comfort and often results in the coil temperature being higher than the dew point of the air creating a muggy feeling within the home The ESP System maintains a constant air off condition and modulates airflow and by doing so continues to remove moisture and runs extremely quiet at night Dual Inverter models utiliz...

Страница 3: ...cts Ltd Model ESP 36 A B C D E F G 38 965 mm 32 813 mm 16 25 413 mm 24 5 624 mm 13 4 340 mm 14 4 366 mm 15 6 396 mm ESP Variable Speed Heat Pump Specifications Dimensions ESP 36 3 Module VAR Variable Speed Heat Pump Installation Specs 3 8 B A D C E F G ...

Страница 4: ...ts Ltd Model ESP 60 A B C D E F G 38 965 mm 53 1346 mm 16 25 413 mm 24 9 633 5 mm 14 6 370 mm 15 9 404 mm 17 6 448mm ESP 60 4 Module VAR Variable Speed Heat Pump Installation Specs 4 8 B C A D E F G ESP Variable Speed Heat Pump Specifications Dimensions ...

Страница 5: ...uction lines Maximum pipe length is 213 ft 65 m Lines must be sized correctly to ensure that pressure drops within the system are minimized HVAC mechanics should refer to the pipe sizing table below prior to installation The ESP comes with a factory charge Additional charge will only be needed on line sets longer than 49 ft Interface Panel The interface panel is critical for indoor and outdoor uni...

Страница 6: ...A1 L N W1 W2 C R Y2 Y1 D O B G FZ W1 Y2 Y1 FZ W2 C R INDOOR UNIT PSB or HEB Circuit Board THERMOSTAT P Pump activates with 2nd stage call for heat W1 1st Stage Heat Inverter W2 2nd Stage Heat Hydronic 24V INPUT External Relay 2 W1 1 Y2 3 Not used 4 Not used C C 24v R 24v 24V OUTPUT 1 1 2 2 3 3 Not Used S2 S1 No Sensor Suction Line Sensor Mid Coil Sensor S2 S1 L1 L2 G INTERFACE PANEL Temperature se...

Страница 7: ... s Electrical Data Power Supply 240 Volts 1 Phase 50 60 Hz Nom Full Load Amps 22 30 Min Circuit Size Amps 25 32 Electrical Input Cooling kW 1 3 25 5 3 Electrical Input Heating kW 1 3 15 5 2 ACOP 3 5 3 38 Sound Pressure dB A 1m 62 63 Soft Starter Variable Frequency Dimensions Outdoor Unit Length 38 965 mm 38 965 mm Width 16 25 413 mm 16 25 413 mm Height 32 813 mm 53 1346 mm Weight 155 lbs 70 3 kg 2...

Страница 8: ...search Development complete with an in house test lab Energy Saving Products prides itself on Customer Service and provides design services and contractor support For all of your Heating Cooling and Indoor Air Quality needs the Hi Velocity System is the right choice for you Phone 780 453 2093 Fax 780 453 1932 Toll Free 1 888 652 2219 www hi velocity com Hi Velocity HE Z Fan Coils Green Technology ...