8. Install the unit and water tank close to each other as much as possible to reduce the distance
between them,so to reduce the energy loss
9.The unit should be free from corrosive and moisture surrounding.Otherwise the lifetime of the
unit might be shortened.
7.Shield the unit from direct sunshine,rain or snow,
but never cover the unit which will cause the bad
ventilation.
6. A mesh filter must be installed in front of the water
inlet of the unit and water tank, for keeping the
water quality and collecting impurity contained
in the water. Take care to keep the water filter
mesh towards the bottom. Check valve is
recommended to be installed at both sides of the
filter, so as to clean or change the filter in a easier way.
2.3 Installation of indoor unit
For the installation of the indoor unit, please refers to the followings:
1.Mark out the positions of the unit bracket on the wall.
2.Drill the holes on the wall.
3.Fix unit bracket with expansion bolts on the wall.
4.Then hand the indoor unit on the bracket.
(refer fig.1)
(refer fig.2)
(refer fig.3)
(refer fig.4)
1
2
3
4
Note:You must choose very firm wall for installation otherwise the bolts may get loose and
cause unit damage!
5.All the hot water pipe and water connections
should be insulated,to reduce the energy loss.
Water inlet
Filter
-17-
2.INSTALLATION
Содержание AWH11-V5+
Страница 2: ......
Страница 31: ...AWH20 V5 30 2 INSTALLATION ...
Страница 32: ... 31 2 INSTALLATION ...
Страница 33: ... 32 2 INSTALLATION ...
Страница 83: ...Cable connected to fan motor capacitor 4 5 4 MAINTENANCE 82 ...
Страница 100: ...R120400472 V1 5 ...