EnerWorks Solar Water Heating Appliance 

 

© 2011 EnerWorks Inc.                            -  Page 

15

  -              

      Energy Kinetics Inc. / Installation 

Manual  

 
Noise is to be anticipated from a pump with moving parts. Pump will operate during 
daylight hours. Homeowner must be aware of anticipated noise and be involved in 
determining best location for Appliance. Noise is not a manufacturing defect and 
does not affect operation of Solar Water Heating Appliance. 
 
Installation of EnerWorks Energy Station requires plumbing to domestic potable 
water distribution network. A plumbing permit may be necessary. An anti-scald 
valve may be necessary and is highly recommended. It is the responsibility of the 
homeowner and of   the installer to obtain any necessary permits and to follow all 
applicable codes and regulations. 

 
 

Connections to domestic potable water distribution network may have to be 
performed by a licensed plumber. It is the responsibility of the homeowner and of 
the installer to follow all applicable codes and regulations. 

 

 
Electrical connections to Energy Station and to solar storage tank may have to be 
done by a licensed electrician. Do not attempt unless fully qualified.  

 

 
This installation may have to be inspected. Follow all codes and regulations. 
 

 

EnerWorks assumes no liability for any damage to property or injury or death 
resulting from improper installation or from modification of the EnerWorks Solar 
Water Heating Appliance. 

 
 

EnerWorks Appliance includes supplies and fittings specific to Energy Station 
connections. Additional materials (copper or PEX and fittings) are required to 
connect water mains to appliance and to connect appliance to hot-water 
distribution network. 

 

MNPT (Male National Pipe Thread), and FIP (Female Iron Pipe) connections all 
require thread sealant or Teflon tape. Do not apply sealant or tape to the first 
thread as it may contaminate water and clog taps and appliances. Do not apply 
thread sealant or Teflon tape to Energy Station flare connections as it may 
contaminate and damage the heat transfer fluid. Degradation of fluid and/or 
damage to appliance due to contamination of fluid is not covered by warranty. 

 
 

A back flow prevention device may need to be installed on water supply to home 
and/or upstream of solar storage tank. Follow all codes and regulations. 

 

 
Before installing the EnerWorks Energy Station, shut down power or gas to 
existing hot-water heater and drain tank. 

 

 

Содержание Smart Solar EWRA1

Страница 1: ...lector Pre heat Appliances EWRA1 DWHX EWRA2 DWHX EWRA3 DWHX EWRA4 DWHX Energy Kinetics Inc 51 Molasses Hill Road Lebanon NJ 08833 Tel 908 735 2066 Toll free 1 800 323 2066 Fax 908 735 2068 www energyk...

Страница 2: ...on of important safety information EnerWorks Residential Solar Water Heating Appliances must be installed as directed by this manual by an EnerWorks authorized dealer or warranty is void CALIFORNIA PR...

Страница 3: ...ar Collector has SRCC OG 100 certification and the EnerWorks Residential Solar Water Heating Appliances are certified to OG 300 standards This certification does not imply endorsement or warranty of t...

Страница 4: ...s are manufactured with tempered glass Though extremely resistant to impact tempered glass can break if an edge is subjected to stress During storage and installation protect glass edges Glass breakag...

Страница 5: ...n 16 4 3 Thermosiphon loop installation 19 4 4 Water connections bypass valves 23 4 5 Water connections cold mains supply 25 4 6 Water connections solar storage hot outlet 26 4 7 Water connection to h...

Страница 6: ...installation 40 7 Appliance Start Up 41 8 Final Steps 42 9 Scheduled Maintenance 42 10 Troubleshooting 43 10 1 Controller 43 10 2 Thermistor 43 10 3 Pump 44 10 4 Noisy pump 45 10 5 Heat transfer flui...

Страница 7: ...ce are off during the installation Do not modify any electrical connections in the EnerWorks Energy Station Cover on Energy Station is designed to protect components from damage and to protect users f...

Страница 8: ...through the heat exchanger and heat is transferred to the potable water After giving up its heat to the potable water the cool heat transfer fluid is pumped back to the solar collectors to be heated...

Страница 9: ...ly blue Hot water supply to home red Thermosiphon loop solar heated water to storage tank red Thermometer Bypass valves to isolate Appliance for service Anti scald valve not included may be required b...

Страница 10: ...capacity Solar storage tank size does not depend on size of existing water heater but on number of solar collectors Number of collectors depends on hot water use and on number of individuals in home S...

Страница 11: ...nd of the day a solar storage tank larger than the minimum required size will provide greater storage capacity of hot water and better performance A smaller family may benefit from a larger tank With...

Страница 12: ...ea that will prevent damage to floors ceilings and furniture in the event of a leak If this is not possible a drain pan must be installed under water heater Pan must have a pipe to a drain or other ou...

Страница 13: ...leak tested charged with heat transfer fluid and purged of air Fittings are insulated and collector flashing is installed Controller and Monitor are programmed and Appliance is commissioned Installer...

Страница 14: ...n from system to reservoir 15 Heat trap 6 120 VAC three prong to grounded surge protected outlet 16 Upper manifold with anti fouling valve 7 Heat transfer fluid pump positive displacement gear pump 17...

Страница 15: ...electrician Do not attempt unless fully qualified This installation may have to be inspected Follow all codes and regulations EnerWorks assumes no liability for any damage to property or injury or dea...

Страница 16: ...late to hide connections see 4 10 1 Over temperature control connection 4 TOP FEED TANK ONLY Remove plastic dip tube from cold port inlet at top of tank optional If no fitting is in cold port apply th...

Страница 17: ...smooth surface of corrugated pipe close to manifold Figs 4 2 2 Do not over tighten as thermistor may dent and damage corrugated pipe 9 Using an accurate pressure gauge check expansion tank air pressu...

Страница 18: ...ghten but do not over tighten as gasket may be damaged Fig 4 2 5 Direct connection for bottom feed tank 13 Lift Energy Station and walk it in to tank such that Energy Station mounting brackets are in...

Страница 19: ...y be exceeded and must not be used 1 Visually inspect hot outlet nipple for heat trap valve or gasket Insert a screw driver into hot outlet to determine presence of heat trap valve or gasket If a heat...

Страница 20: ...elbow x sweat fittings with an angled pipe length between them Thermosiphon loop will consist of vertical riser and horizontal section with angled 45 section in between Fig 4 3 2 Adjust orientation o...

Страница 21: ...more hot water out of insulated storage tank A reverse thermosiphon effect will occur during times of low solar radiation transferring heat from hot water tank to surrounding room Benefit of solar wil...

Страница 22: ...lar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 22 2011 EnerWorks Inc Remove thermometer from well before soldering Do not install thermometer until soldering is complete and...

Страница 23: ...tting and line downstream of ball valve must be rigid copper as temperature of solar heated water may exceed PEX ratings 2 Tee fitting above ball valve will direct mains water supply to cold mains inl...

Страница 24: ...EnerWorks Solar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 24 2011 EnerWorks Inc Fig 4 4 1 Bypass valve configuration...

Страница 25: ...trap Sweat connections using lead free solder and appropriate plumbing techniques If supply is PEX use installer supplied fittings for connection 3 To maintain system certification SRCC requires 5 of...

Страница 26: ...roduce very hot water that exceeds PEX temperature ratings 4 7 Water connection to hot water distribution network 1 Ensure hot water outlet of pre existing now back up water heater is connected to hom...

Страница 27: ...loss and prevent condensation Fig 4 6 1 2 If anti scald valve is installed highly recommended or required check local code adjust set point if required by code or to homeowner s specifications 3 Do no...

Страница 28: ...9 1 1 Line set connections to Energy Station Note For clarity line set is not insulated Proper installation must have insulated line set to prevent heat loss and to limit burn risk 4 9 2 Supplemental...

Страница 29: ...ank tee flare to flared port on upper manifold of Energy Station Install a smooth and continuous line without unnecessary bends Slide on line insulation and cut insulation to appropriate length Slide...

Страница 30: ...e on top of solar storage tank Fig 4 10 1 1 3 Punch out one round insert if necessary and install cable clamp Fig 4 10 1 2 4 Insert over temperature wire through connector nut Feed enough wire through...

Страница 31: ...hermostat Connect black wire descending from top to vacant terminal of thermostat Fig 4 10 1 5 13 Set lower thermostat setting to 120 F 50 C Fig 4 10 1 5 Carefully stow wires Reinstall insulation and...

Страница 32: ...d 6 to Common Com and to Source Src Fig 4 11 2 8 Replace connection cover Replace snap on cover and push Controller assembly down 9 Temporarily plug in Energy Station LCD screen default display is tem...

Страница 33: ...urn fluid from appliance to reservoir to left pointing male quick connect when facing Energy Station on lower manifold Fig 5 1 1 Return connection assembly includes female hydraulic quick connect coup...

Страница 34: ...Propylene Glycol Two jugs are included with two three and four collector appliances Pour 100 propylene glycol USP into EnerWorks Charge Pack reservoir or into a large clean bucket Add an equivalent am...

Страница 35: ...with switch it is much easier to start and stop charge pump by using a switch Switch on charge pump to circulate fluid and remove air from appliance 4 With charge pump operating observe clear line ret...

Страница 36: ...LCD will turn on for 3 seconds and temperature difference T is displayed see Appendix Controller Operation Energy Station circulation pump is a positive displacement gear pump When not operating gear...

Страница 37: ...momentarily Switch off pump and close valve as before If pressure is above 30 psi let very small volume of fluid out of appliance outlet 9 Disconnect supply and return charging hoses from appliance O...

Страница 38: ...Water Heating Appliance Installation Manual Energy Kinetics Inc Page 38 2011 EnerWorks Inc Before installing flashing and leaf guard confirm no leaks at panel s insulate line set and record collectors...

Страница 39: ...nd snow shedding Secure upper side flashing to roof with included roofing screws 3 Insert rectangular caps into upper and lower holes created by side flashing and collector Fig 6 1 1 Secure to roof wi...

Страница 40: ...etween collectors try loosening C channel bolts temporarily Be sure to re tighten C channel bolts after center flashing is started in side wall grooves It may also help to bow the center flashing sect...

Страница 41: ...th included roofing screws Fig 6 3 1 4 Secure end caps to leaf guard sections and secure sections to each other at overlaps with self drilling screws 5 Bend center flashing down to leaf guard and secu...

Страница 42: ...Serial numbers of Energy Station and collectors and thermistor sticker are necessary for timely and effective service 3 Provide homeowner with Owner Manual and a copy of Product Installation Registrat...

Страница 43: ...is faulty If points to Storage storage tank thermistor circuit is shorted or open or thermistor is faulty Check and fix connections or replace thermistor if necessary see below 10 2 Thermistor 1 Chec...

Страница 44: ...18 F 10 C hotter than mains ground water temperature and pump will operate Pump is not operating 1 If LCD screen on Controller is blank check power to Energy Station 2 If Err shows on Controller refer...

Страница 45: ...If pressure is low check for and fix any leaks 1 Identify location of fluid leak wetness or discoloration may indicate source of leak 2 Quick connects fluid ports may be dirty or faulty copper shavin...

Страница 46: ...EnerWorks Solar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 46 2011 EnerWorks Inc Exploded Views Fig A 1 Energy Station exploded view Fig 85 Energy Station exploded view...

Страница 47: ...EnerWorks Solar Water Heating Appliance 2011 EnerWorks Inc Page 47 Energy Kinetics Inc Installation Manual Fig A 2 Expansion tank upper manifold exploded view Fig A 3 Lower manifold exploded view...

Страница 48: ...EnerWorks Solar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 48 2011 EnerWorks Inc...

Страница 49: ...be done with Energy Pack unplugged Do not connect or disconnect any wires to terminals at lower left of controller Current flows through these connections and there is a danger of shock and of damagi...

Страница 50: ...oduction should in no way be used to assess energy displacement for billing purposes Program PRGM Mode To enter program PRGM mode push and hold all three buttons By pushing Item button Controller cycl...

Страница 51: ...ly for Space SaverTM Appliance Default 185 F 85 C to 122 F 50 C Maximum Storage Diff l Differential for Maximum Storage setpoint temperature DO NOT MODIFY Default 9 F 5 C F or C blinking Temperature u...

Страница 52: ...EnerWorks Solar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 52 2011 EnerWorks Inc Product Installation Registration Form...

Страница 53: ...EnerWorks Solar Water Heating Appliance 2011 EnerWorks Inc Page 53 Energy Kinetics Inc Installation Manual Maintenance Log...

Страница 54: ...EnerWorks Solar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 54 2011 EnerWorks Inc Residential Site Survey...

Страница 55: ...EnerWorks Solar Water Heating Appliance 2011 EnerWorks Inc Page 55 Energy Kinetics Inc Installation Manual...

Страница 56: ...EnerWorks Solar Water Heating Appliance Installation Manual Energy Kinetics Inc Page 56 2011 EnerWorks Inc Tool and Supply Checklist...

Отзывы: