Energy Cube AP4050 Скачать руководство пользователя страница 5

 Exhaust heat/gases could ignite 

combustibles, structures or 
damage fuel tank causing a fire, 
resulting in death, serious injury 

and/or property damage. Contact with muffler 
area could cause burns resulting in serious injury.

• DO NO

T touch hot parts and A

VOID hot 

exhaust gases.

 Allow equipment to cool before touching.

• Keep at least 5 feet (1.5m) of clearance on all 

sides of generator including overhead.

• It could be a violation of to use or operate the 

engine on any forest - covered, brush - covered, 
or grass - covered land unless the exhaust system  
is equipped with a spark arrester.

Contact the original equipment manufacturer, 
retailer, or dealer to obtain a spark arrester 
designed for the exhaust system installed on this 
engine.

• Replacement parts must be the same and 

installed in the same position as the original parts.

WHEN ADJUSTING OR MAKING REPAIRS 

TO YOUR GENERATOR

• Disconnect

  the  spark  plug  wire  from  the  spark 

plug and place the wire where it cannot contact spark 
plug.

WHEN TESTING FOR ENGINE SPARK

• Use approved spark plug teste

r.

• DO NOT check for spark with spark plug 

   removed.

  

 Exceeding generators wattage/ 

amperage capacity could damage generator 
and/or electrical devices connected to it.

• DO NO

T exceed the generator’s wattage/ 

amperage capacity

. See Don

t Overload 

Generator in the Operation section.

• Start generator and let engine stabilize before 

connecting electrical loads.

 T

urn electrical loads OFF and disconnect from 

generator before stopping generator.

Unintentional sparking could 

cause fire or electric shock 
resulting in death or serious 
injury.

  

    

 Starter and other rotating parts 

could entangle hands, hair, clothing, or 
accessories resulting in serious injury.

• NEVER operate generator without protective 

housing or covers.

• DO NO

T wear loose clothing, jewelry or 

anything that could be caught in the starter or 
other rotating parts.

 Tie up long hair and remove jewelry.

        

  Excessively high operating 

speeds could result in minor injury and/or 
generator damage.
Excessively low speeds impose a heavy load.

• DO NO

T tamper with governor spring, links or 

other parts to increase engine speeds. Generator 
supplies correct rated frequency and voltage 
when running at governed speed.

• DO NO

T modify generator in any way.

         

 Improper treatment of generator 

could damage it and shorten its life.

• Use generator only for intended uses.

• If you have questions about intended use, ask 

dealer or contact local service center.

• Operate generator only on level surfaces.

• DO NO

T expose generator to excessive 

moisture, dust, dirt, or corrosive vapor.

• DO NO

T insert any object through cooling 

slots.

• If connected devices overheat, to turn them o

ff 

and disconnect them from generator.
-or electrical output is lost.
-or equipment sparks, smokes, or emits flames.
-or unit vibrates excessively.
to turn them off and disconnect them from 
generator.

3

         

                        There is a permanent conductor 

between the generator (stator winding) and the 

frame.

Содержание AP4050

Страница 1: ...RVICE SERVICE CLIENTELE SERVICIO AL CLIENTE 888 980 4936 SAVE THIS MANUAL FOR FUTURE REFERENCE IMPORTANT SAFETY INSTRUC LIMITED WARRANTY YEAR TIONS ARE INCLUDED IN THIS MANUAL A iPOWER Corp 1477 E Ced...

Страница 2: ...2 Adding Fuel 6 4 3 Grounding the Generator 6 5 1 Starting the Engine 7 5 2 Connecting Electrical Loads 9 5 3 Stopping the Engine 9 5 4 Low Oil Level Shut down System 9 5 5 High Altitude 9 6 1 Mainte...

Страница 3: ...accurate and current However Energy Cube reserves all rights to change alter or otherwise to improve the generator and this documentation at any time without prior notice If any portion of this manual...

Страница 4: ...il it evaporates before starting engine Keep fuel away from sparks open flames pilot light heat and other ignition sources Check fuel lines tank cap and fittings frequently for cracks or leaks Replace...

Страница 5: ...e before connecting electrical loads Turn electrical loads OFF and disconnect from generator before stopping generator Unintentional sparking could cause fire or electric shock resulting in death or s...

Страница 6: ...it 2 2 1 ASSEMBLING THE ACCESSORY KIT The wheels are designed to greatly improve the portability of the generator Refer to Figure to install wheels as shown Refer to Figure to install the leg support...

Страница 7: ...controls and adjustments Save this manual for future reference Pictures and drawings used in this manual are for reference only and do not represent any specific model 5 12 2 3 1 5 4 6 8 7 11 13 9 10...

Страница 8: ...oisture which leads to separation and formation of acids during storage Acidic gas can damage the fuel system So the fuel should be emptied before storage of 30 days or longer See the Storage section...

Страница 9: ...VD CD Player 100 VCR 100 Stereo Receiver 450 Color Television 27 in 500 Personal Computer w 17 in monitor 800 Other Security System 500 AM FM Clock Radio 100 Garage Door Opener 1 2 HP 875 2350 Electri...

Страница 10: ...ea could cause burn resulting in serious injury DO NOT touch hot part and AVOID hot exhaust gases Allow equipment to cool before touching Keep at least 5 feet 152 cm of clearance on all sides of gener...

Страница 11: ...rated wattage of tools appliances and motors can usually be found on a data label Some electric motors such as induction types require about three times more watts of power for starting than for runni...

Страница 12: ...p loose dirt and debris Low pressure air not to exceed 25 psi may be used to blow away dirt Inspect cooling air slots and openings on the generator These openings must be kept clean and unobstructed F...

Страница 13: ...s damaged Installation of the spark arrester screen is the reverse of the removal The engine will not run properly and may be damaged if using a dirty air filter Replace the air filter once a year Cle...

Страница 14: ...el system should be emptied before storage of 30 days or longer as follows Drain fuel into approved container outdoors away from open flame Be sure engine is cool Do not smoke Remove all gasoline from...

Страница 15: ...6 Clean or replace fuel filter 7 Out of fuel 7 Fill fuel tank 8 Stale fuel 8 Drain fuel tank and carburetor fill with fresh fuel 9 Spark plug wire not connected to spark plug 9 Connect wire to spark...

Страница 16: ...Model AP4050 Engine Kohler 7 0HP Displacement 208cc Rated frequency 60Hz Rated voltage 120V Running watts 3050W Starting watts 4050W Fuel tank capacity 4Gallon Full load continuum running time 8 0H 1...

Страница 17: ...k blue brown yellow yellow yellow AVR secondary winding excitation winding generator part blue blue blue brown control panel engine switch engine part oil sensor oil alert spark plug ignition coil RV...

Страница 18: ...owner s manual Energy Cube recommends that you retain all receipts covering maintenance on your spark ignited small off road engine but Energy Cube cannot deny warranty solely for the lack of receipts...

Страница 19: ...in the Owner s Manual No express Emission Control System Warranty is given by Aipower with respect to the engine except as specifically set forth in this document Any Emission Control System Warranty...

Страница 20: ...performance and reliability This warranty also does not cover regular maintenance and parts such as air filters OTHER EXCLUSIONS This warranty excludes wearing parts such as o rings filters etc or ma...

Страница 21: ...del Color Claim Number Registration Number Circle one Consumer Dealer Service Did you send in your Warranty Card If not proof of purchase is required Yes No Have you ever had a warranty issue with the...

Страница 22: ...Phone 1 888 980 4936 support a ipower com www a ipower com We are professional generators 1477 E Ced A iPower Corp ar Street B Ontario CA 91761 U S A...

Отзывы: