series

2.2 

Make Sure You Have Everything

Number

Part Name

Quantity

1

eZG7250 Generator

1

2

Handle Bracket Bolt 1

2

3

Handle Axis Bolt 1

2

4

Handle Bracket

2

5

Handle Axis Nut 1 

2

6

Handle Lock Pin & Leash

2

7

Handle Bracket Bolt 2

2

8

Foot Riser Nut

4

9

Wheel Axle Bolt

4

10

Wheel Axle

1

11

Foot Riser Support

2

12

Anti-Sink Plate

1

13

Rubber Feet

2

14

Foot Washer

2

15

Foot Bolt

2

16

Wheel Washer

4

17

Wheel

2

18

Wheel Nut

2

19

Handle

2

20

Handle Grip

2

Using a generator indoors  can  KILL  YOU  IN MINUTES. Generator exhaust  contains 
carbon  monoxide.  This is  poison  that  you  cannot  see or  smell.  NEVER  use inside  a 
home or garge. EVEN if doors and windows are open. Only use OUTSIDE and far wawy 
from windows, doors, and vents.

Utiliser  un générateur  à  l’intérieur  VOUS  TUERA EN  QUELQUES MINUTES. 
L’Échappement des générateurs  contient  de monozyde de  carbone  (CO),  un gaz 
toxique que vould ne pouvez ni voir ni sentir. N’utilisez un générateur à l’intérireur d’une 
maison, dans un garage, MÊME SI les fenêtres et portes seront overts. N’untilisez pas 
un générateur  qu’à l’EXTÉRIEUR et bien loin des fenêtres, portes et évents overts.

W

ARNIN

G

Toxic Fumes Hazard

. Running engines give 

off carbon monoxide, an odourless poisoness 
gas that can cause nausea, fainting, or death. 
Do not start or run engine indoors or in an 
enclosed area, even if windows and doors are 
open.

Fumées toxiques dangereuses

 – les moteurs en marche émettent 

du monoxyde de carbone, un gaz inodore et dangereux qui peut 
causer des nausées, des évanouissements ou même la  mort. Ne 
faites pas démarrer ou fonctionner un moteur à l’intérieur ou dans une 
aire fermée, même si les fenêtres et les portes sont ouvertes

 

  U

nl

ea

de

G

as

ol

in

O

nl

  

   D

o n

ot 

ove

r ll  

    Essence sans plo

mb s

eule

m

en

t   

   N

e p

as

 tro

ps

 re

m

plir

29

L

Capacite du reservoir

Tank Capacity

Accessorize

Your Generator

Call 1-877-528-3772 or visit

www.energizergenerators.com

to learn more.

Accessoiriser

votre générateur

Appeler au 1-877-528-3772 ou visiter

www.energizergenerators.com pour en

savoir plus.

AC Voltage

Voltage AC

120V/240V

Power Output

Energie

Max. Ambient Temperature 40ºC

Temperature Ambiante Maximale

7250W

Max. AC Output

Production maximale de voltage AC

6500W

Phase

/Phase

1

Insulation Class

F

Classe D’isulation

Frequency

/Fréquence

60Hz

Run Time (75% load)

Continuation

10 hrs

Engine RPM

TR/MIN du moteur

3600

Fuel

Carburant

Gasoline/Gaz

Serial No.

©2012 Energizer     Energizer and other marks, including 

graphics, are trademarks of Energizer and are used under 

license by Midland Power Inc. L’Energizer et les autres marques, 

y compris les illustrations, sont des marques de commerce 

d’Energizer et sont utilisées sous licence par Midland Power Inc.

1-877-528-3772

www.energizergenerators.com

THIS ENGINE CONFORMS TO U.S. EPA REGULATIONS FOR 2012

CE MOTEUR EST CONFORME AUX NORMES EPA AMÉRICAINES POUR 2012.

Engine Family Name

Nom de famille du moteur

CCPTS.4201PL

Engine Displacement

Déplacement du moteur

420cc

Date of Establishment

Date d’établissement

2013

Exhaust Emission Control

Contrôle d’échappement du moteur

EM

Emission Compliance Period

Période de conformité d’échappement

125HR

Lubricant Requirement

10W-30

Chongqing Panlong Technology Development Co. Ltd.

Содержание eZG3500

Страница 1: ......

Страница 2: ...2 2014 Energizer Power Equipment All Rights Reserved Licensed by Energizer Corporation United States of America EZG7250 06 2013 01 series...

Страница 3: ...3 series Let s get started You re excited to power up so we ll keep this brief...

Страница 4: ...mber to register Take a minute to register this product online at www energizergenerators com This will allow you to request warranty support in the future This manual will show you how to use the gre...

Страница 5: ...ZG7250 All information in this publication is based on the latest product information available at the time of print Visit www energizergenerators com for user guide updates and operation notices No p...

Страница 6: ...operation assistance and product support is provided by Midland International Inc a licensed manufacturer of En ergizer Power Equipment Please contact us directly for any warranty service questions 1...

Страница 7: ...7 series 8 8 9 9 10 11 11 13 14 17 17 18 19 20 21 21 23 24 25 25 25 26 27 28 29 31 32 33 34...

Страница 8: ...ons of a poisonous carbon monoxide gas Be careful not to touch the exhaust system compressor pump or discharge tubing during operation due to risk of burns Pay attention to the warning labels The engi...

Страница 9: ...n electrical shock Turn off the generator immediately if the device begins to operate abnormally Then disconnect the device and investigate the problem Make sure that the electrical rating of the devi...

Страница 10: ...stop the generator set before removing the oil filler cap Only qualified maintenance personnel with knowledge of fuels electricity and machinery hazards should perform maintenance procedures Lubricate...

Страница 11: ...hapter 2 Learn About Your Generator This section will show you how to identify key parts of your generator Going over the terminology below will make sure we re on the same page 2 1 Identification of...

Страница 12: ...oid short circuit Recharge after use Must be disposed and recycled properly Never disassemble or heat above 50 C Never Incinerate Ne jamais recharger dans un contenant sell nvitez un court circuit Fai...

Страница 13: ...ou m me la mort Ne faites pas d marrer ou fonctionner un moteur l int rieur ou dans une aire ferm e m me si les fen tres et les portes sont ouvertes U n l e a d e d G a s o l i n e O n l y D o n otov...

Страница 14: ...ttach the two peg stands at the bottom of the frame of the genera tor Tighten the two bolts 6 and two nuts 7 to the lower frame of the generator 3 Place the two wheels 5 on the wheel axle 4 and then s...

Страница 15: ...15 series Rubber washers...

Страница 16: ...16...

Страница 17: ...r is air cooled and may be damaged if ventilation is inadequate 3 1 Checking the Engine Oil Level 5 Ensure the generator is on a level surface 6 Inspect engine oil Take out the oil filler cap and clea...

Страница 18: ...and explosive under certain conditions Refuel in a well ventilated area with the engine stopped Do not smoke or allow open flames or sparks in the area where the generator is being refueled or where g...

Страница 19: ...nt with soap and water or solvent Squeeze dry and then soak in clean engine oil 3 Squeeze out all excess oil and reinstall Replace the element if it is damaged Check the air filter using the maintenan...

Страница 20: ...s secured by using the fastener at the battery terminal 2 Connect the black cabel with the negative terminal of the battery ensure the connection is secured by using the fastener at the battery termin...

Страница 21: ...oors and vents These openings can pull in generator exhaust Even when you use a generator correctly CO may leak into the home ALWAYS use a battery powered or battery backup CO alarm in your home If yo...

Страница 22: ...above the air filter cap on the left side of your generator 3 Disconnect all devices from the outlets on the generator panel Then press the engine switch to the RUN position 4 Grasp the recoil stater...

Страница 23: ...W circular saw a 500W drill and a 100W light at the same time 4500W combined However to operate a second 900W saw it will be necessary to disconnect one of the 1500 W heaters 1 Turn off the switches o...

Страница 24: ...AVR Your generator is equipped with an Automatic Voltage Regulator which ensures a con stant voltage and present a waveform similar to what you get from the city power grid They are an improvement ov...

Страница 25: ...ion Engine Lubricants Inspect Oil Level Replace Air Filter Inspection Cleaning Sediment Cup Cleaning Spark Plug Inspection Cleaning Replacement Valve Clear ance Inspection Adjusting Combustion Chamber...

Страница 26: ...n Do not operate this product without an air filter 1 Rotate the knob counterclockwise to release 2 Lift the filter cap to remove from the filter 3 Remove the foam filter 4 If the foam filter is dirty...

Страница 27: ...s or on soil Local service shops provide environmentally friendly disposal methods 1 Stop the engine and remove oil filler cap 2 Place a pan under the engine 3 Remove the oil drain screw and allow the...

Страница 28: ...d spark plug 1 Disconnect and remove the spark plug using a wrench 2 Inspect the spark plug and clean any dirt from the electrodes with a wire brush If electrodes are worn or show signs of wear replac...

Страница 29: ...at a level position in order to prevent spillage Storage Before storing the generator set for an extended period 1 Ensure that the storage area is free of excess humidity and dust 2 Drain the fuel tan...

Страница 30: ...drain completely drain and re tighten the drain screw Disconnecting the Electric Start Battery 1 disconnect red cable from the bositive battery terminal 2 disconnect black cable from the negative batt...

Страница 31: ...in closed position Open choke Dirty air filter Clean air filter Rich fuel mixture Contact customer service Engine stops No fuel Refill fuel tank Not enough oil Add more oil Engine has dif ficulty idli...

Страница 32: ...ement cm3 420cc Ignition mode Transistor Controlled Ignition Starting mode Recoil Start Electric Start Max Output W rpm 7250 3600 Fuel tank capacity 29L 25L CA model Oil capacity 1 1L 10W30 Fuel Type...

Страница 33: ...33 series Chapter 8 Wiring Diagram...

Страница 34: ...components or workmanship during the three 3 Year period The warranty coverage is continual from the initial date of purchase and does not restart at anytime under any circumstances This limited warr...

Страница 35: ...arranty EXCLUSIONS NOT COVERED BY THIS LIMITED WARRANTY 1 Normal engine alternator wear 2 Damage caused by lack of maintenance as described in the Energizer User Guides or negligence by using improper...

Страница 36: ...Air filter element Ignition Flywheel magneto Ignition pulse generator Crankshaft position sensor Power coil Ignition coil assembly Ignition control mod ule Spark plug cap Spark plug Crankcase Emission...

Страница 37: ...land Power Inc are pleased to explain the emission control system warranty on your Midland Power Inc engine In California new spark ignited small off road equipment engines must be designed built and...

Страница 38: ...38...

Страница 39: ...your product packaging The store date of purchase and product purchase should be clearly visible on the receipt copy You may also register online by visiting our website www energizergenerators com I...

Страница 40: ...40...

Страница 41: ...ued warranty and service support Warranty support cannot be provided without registration from original date of purchase and after transfer of ownership This transfer form must be completed on or befo...

Страница 42: ...42 Enjoy Be sure to check energizergenerators com monthly for updates regarding your generator...

Страница 43: ...43 series series...

Страница 44: ...44 TM...

Отзывы: