Energizer EN1100 Скачать руководство пользователя страница 4

 

appliance. If the appliance label states that the charger or adapter 

produces a low-voltage DC or AC output (30 volts or less), there will 

be no problem powering that charger or adapter. 

 

Some fans with synchronous motors may slightly increase in speed 

(RPM) when powered by the inverter. This is not harmful to the fan 

or to the inverter. 

 

Route appliance cords and extension cords to prevent accidental 

pinching, crushing, abrading and tripping people. 

 

Use safety approved extension cords rated at 15 amps or higher. 

 

GFCI devices may not work with modified sine wave (MSW) power. 

 

This inverter is not tested for use with medical equipment. 

 

This inverter is not tested for use in marine applications.  

 

In the event of a continuous audible alarm or automatic shut down, 

turn the inverter OFF immediately. Do not restart the inverter until the 

source of the problem has been identified and corrected.   

 

When attempting to power lead acid battery chargers, with modified 

sine wave, monitor the temperature of the battery charger for 

approximately 10 minutes. If the battery charger becomes 

abnormally warm, immediately disconnect it from the inverter. 

 

Getting Started    

When a motorized appliance or a tool turns on, there is an initial surge of 

power to start. This surge of power is referred to as the "starting load" or 

"peak load." Once started, the tool or appliance requires less power to 

operate. This is referred to as the "continuous load" in terms of power 

requirements. You will need to determine how much power your tool or 

appliance requires to start up (starting load) and its continued running 

power requirements (continuous load).   

 

Power consumption is rated in watts, or it can be calculated from 

amperes (amps). This information is usually stamped or printed on most 

appliances and equipment. If this information is not indicated on the 

appliance or equipment, check the owner's manual.  For electrically 

sensitive equipment, contact the manufacturer to determine if the device 

you are using is compatible with modified sine wave AC. 

 

 

 

Содержание EN1100

Страница 1: ...1...

Страница 2: ...pliance or a combination of appliances run a test All inverters are designed to automatically shut down in the event of a power overload This protection feature prevents damage to the unit while testi...

Страница 3: ...eration The unit will shut down if the internal temperature gets too hot Restart the inverter after it cools This Energizer inverter will only operate from a 12V power source Do not attempt to connect...

Страница 4: ...o power lead acid battery chargers with modified sine wave monitor the temperature of the battery charger for approximately 10 minutes If the battery charger becomes abnormally warm immediately discon...

Страница 5: ...f your appliance Multiply WATTS X 2 Starting Load for most appliances This formula yields a close approximation of the starting load of most appliances Exceptions are motorized appliances such as pump...

Страница 6: ...ts ON and OFF C Display Selector Switch D Two standard North American AC outlets each rated at 15 Amps 1650 Watts E Two USB Ports 2 1 Amp Shared LCD Diagram 1 Battery Level 2 Output wattage W or input...

Страница 7: ...DC Power Requirements Powering multiple appliances from the high power EN900 EN1100 inverter requires a 12 volt bank of batteries several batteries To calculate the approximate power in amps a 12 volt...

Страница 8: ...ultiply the average power consumption in watts by the number of hours of run time For example 900 watts for 10 hours 9 000 watt hours Using the 900 watts or 90 Amps for 10 hours example as above then...

Страница 9: ...e explosions Energizer recommends installing one ANL type fuse and fuse holder close to the positive battery bank terminal This fuse protects the batteries from accidental DC cable shorts which can ca...

Страница 10: ...ks directly behind the surface to be drilled To mount the inverter 1 Inverter must be OFF 2 The inverter should be mounted horizontally 3 Position the inverter against the mounting surface and mark lo...

Страница 11: ...er 4 Turn ON the inverter 5 Turn the appliance on 6 Plug in additional appliances and turn them on Note The audible alarm may make a momentary chirp when the inverter is turned OFF This same alarm may...

Страница 12: ...o the food being cooked The actual operating power rating is listed on the back of the microwave If the operating power cannot be found on the back of the microwave check the owner s manual or contact...

Страница 13: ...fied to be lead free Transformers in this inverter contain nickel composites Nickel is a known neuro toxin if ingested Troubleshooting PROBLEM No Input Voltage Reason Solution Poor contact with batter...

Страница 14: ...tain regulation Poor or weak battery condition Recharge or replace battery Inadequate power being delivered to the inverter or excessive voltage drop Use lower gauge heavier cable Keep cable length as...

Страница 15: ...Optimum Efficiency 90 min Fuse A 35A 3 Fuse Type Internal Blade Output Wave Form Modified Sine Wave Max Touch Temperature 65 C Max Operating Temperature 0 to 40 C Operating Storage Humidity RH 5 to 9...

Страница 16: ...DC Optimum Efficiency 90 min Fuse A 40A 3 Fuse Type Internal Blade Output Wave Form Modified Sine Wave Max Touch Temperature 65 C Max Operating Temperature 0 to 40 C Operating Storage Humidity RH 5 to...

Страница 17: ...the right to use parts or products of original or improved design in the repair or replacement If PowerBright repairs or replaces a product its warranty continues for the remaining portion of the orig...

Страница 18: ...enerators and lightning strikes 3 the product if repairs have been done to it other than by PowerBright or its authorized service centers hereafter ASCs 4 the product if it is used as a component part...

Страница 19: ...product Information about the installation and use of the unit Information about the failure and or reason for the return A copy of your dated proof of purchase Return Procedure 1 Package the unit sa...

Страница 20: ......

Отзывы: