ECONOMIC

Technical Manual

English

3.3.4.Thermodynamic Solar Panel

Right Panel

The solar panel is a double channel pressed 

aluminium,  with  a  post-press  anodization

-

-oxidation that creates a dark tone aspect 

with  the  Solokote  finishing.  There  are  two 

types of panels available: left and right (de

-

signated according to side of connections). 

The panels have the following pipe diame

-

ters:

• 3/8” Aspiration (upper connection)

• 1/4” Liquid (lower connection)

Left Panel

ODS  (welded  to  panel) 
3/8” flare Male SAE

ODS (welded to panel)
1/4” flare Male SAE

[1]

 Thermodynamic Solar Panel

[2]

 Fixing elements

[3]

 Aluminium brackets (3x small + 3x large)

2

3

1

The parts provided for each panel are the following:

Содержание ECONOMIC 250

Страница 1: ...s Directives Directives 2006 95 CE Certifica o Europeia European Certification Certification europ enne EN 60335 1 EN 60335 2 21 EN 60335 2 40 Revis o Review R vision Vers o Version Version Data Date...

Страница 2: ......

Страница 3: ...omote power saving in our products Your choice has demonstrated your good sense and concern with pow er consumption a matter that affects the environment We have taken on a permanent commitment to con...

Страница 4: ...3 4 1 Safety Thermostat 3 4 2 Protection against corrosion 3 4 3 Expansion Vessel not supplied 3 4 4 Safety Group 3 4 5 Pressure Reducing Valve not supplied 4 INSTALLATION 4 1 Thermodynamic Solar Pane...

Страница 5: ...s 5 SYSTEM OPERATION 6 TROUBLESHOOTING 7 MANUTEN O DO SISTEMA 7 1 General Inspection 7 2 Magnesium Anode 7 3 Cleaning Filter of Pressure Reducing Valve 7 4 Safety Thermostat 7 5 Empty the Hot Water Cy...

Страница 6: ...cable is damaged it must be replaced by the manufacturer customer service or technicians with simi lar training in order to avoid any danger This appliance is not intended for use by people including...

Страница 7: ...However according to the law the refrigerant in this equipment cannot be released into the environment Handling of the refrigerant in the equipment must be carried out by a qualified technician Infor...

Страница 8: ...n suitable for the equipment pallet lift forklift etc AVISO 2 2 Transport The equipment must be transported in its original package to the place of installation Check before beginning transport the un...

Страница 9: ...x ternal agents mentioned above and the fluid inside the solar panel makes the fluid to eva porate on its inside The absence of glass in the solar panel allows for an increased ther mal heat exchange...

Страница 10: ...lectrical Backup Power W 1500 Refrigerant Qt g R134a 1100 Piping Material Copper DHP ISO1337 Refrigerant connections Liq Asp inch 1 4 3 8 Power Supply V Hz 220 240 50 Single phase Running Temperature...

Страница 11: ...eneral Assembly 1 Hot Water Cylinder 2 Thermodynamic Block 3 Thermodynamic Solar Panel 4 Fixation elements 5 Insulated Copper Pipes not supplied 6 Expansion Vessel not supplied 7 Safety Group 7bar not...

Страница 12: ...nual English 3 3 2 Dimensions Thermodynamic Solar Panel Indoor Unit C Cold water inlet R Recirculation A Magnesium Anode PT TPR Valve optional H Hot water outlet V Hz Power supply 2WV 3WV Refrigeratio...

Страница 13: ...e 9 Power Supply voltage frequency 10 Protection Index 11 Fluid type amount 12 Maximum Power Absorbed with electric heater backup When contacting the installer or manufacturer make sure you have the f...

Страница 14: ...here are two types of panels available left and right de signated according to side of connections The panels have the following pipe diame ters 3 8 Aspiration upper connection 1 4 Liquid lower connec...

Страница 15: ...ier 7 Unidirectional valve 8 Load read Valve 9 Compressor 10 Thermostatic Expansion Valve 11 Electric Electronic circuit box 2 Storage water The hot storage water heater is vertical and rests on the f...

Страница 16: ...he consequence of any water hammer effect Installing this device is a re commended procedure for a correct installation of the equipment Installing this device is the responsibility of the installer A...

Страница 17: ...emisphere The panel already comes with 6 holes for M8 in the lateral bends The distance between holes in the place where the panel rests should coincide with the holes made in the panel DANGER The ins...

Страница 18: ...s as a guide bar for the holes drilled at the base This marking follows the diagram below 4 2 Set up of the Hot Water Cy linder Thermodynamic Block Pre requisites Choose the position closer to the mai...

Страница 19: ...pipe removing the protective caps from the extremities b Place the extremity of the pipe upside down cut the appropriate size of pipe and trim the rough edge c Remove the females from the connec tion...

Страница 20: ...of the pipe c Tighten the female coupling with your hand by giving it a few turns We recommend the use of a sui table thread sealant The sealant should be placed between these two steps c d If in dou...

Страница 21: ...vacuum pump working for at least 30 min f Once the vacuum procedure is over shut the vacuum pump valves The vacuum pressure gauge should indicate the same reading after the pump has been stopped ensur...

Страница 22: ...each the figure intended for the injection of cooling fluid into the circuit close the bottle handle and remove the hose connected to the 3 way valve f Switch on the compressor and check the pressures...

Страница 23: ...check these conditions a The thermodynamic equipment must be plugged to the power supply only after fil ling entirely the hot water cylinder b The thermodynamic solar system must be connected to a sin...

Страница 24: ...ionella cycle VS Solenoid valve R1 Auxiliary relay LP Low Pressure switch Sc Condenser running compressor RES Heather ON OFF indicator B1 Button ON OFF heather i ON Anti Legionella ii ON Heather 0 Hea...

Страница 25: ...of the le gionella cycle I Start this cycle when there are no consumptions II Once the cycle is finished you must return manual to the previous position III AThe Cycle off ant legionella must be done...

Страница 26: ...running of thermostat Slow running of Thermody namic Solar System Outside air temperature is very low The running of the equipment depends on weather conditions Inlet water temperature is very low The...

Страница 27: ...eption of the useful life left for the appliance Seek advice with your installer about how you should proceed to control the anode s condition To check the condition of your anode follow these steps S...

Страница 28: ...ely you should contact a qualified te chnician for that purpose The container symbol on the type plate of the product indicates that this appliance may not be treated as household waste Instead it mus...

Страница 29: ...e of modifications and or if the series number appears to have been removed or erased The equipment should be installed by qualified technicians according to the rules in effects and or the rules of t...

Страница 30: ...Notas Notes...

Страница 31: ...Notas Notes...

Страница 32: ...Notas Notes...

Страница 33: ...Notas Notes...

Страница 34: ...Notas Notes...

Страница 35: ......

Страница 36: ...nergie pt Web www energie pt Morada Zona Industrial de La ndos Lote 48 4570 311 La ndos P voa de Varzim PORTUGAL GPS N 41 27 215 W 8 43 669 Telefone 351 252 600 230 Projeto co financiado por Proyecto...

Отзывы: