The panel must be installed facing down, that is, the connections must be turned down.
[A]
Liquid inlet
[B]
Vapour outlet (aspiration)
9.2.
SET-UP OF THE STORAGE WATER HEATER
Keep the equipment sheltered in places susceptible to ice crystals
Choose the position closer to the main user points
Always insulate the piping
The temperature around the equipment must not exceed 40 °C
The storage water heater must never be kept outside, and avoid exposure to sunlight
Make sure the support surface is enough to accommodate the weight of the storage water heater
filled with water (Min. 710 lb)
9.3.
INSTALLATION THERMODYNAMIC GROUP
When installing the thermodynamic Group, you must:
a)
Tighten the three M8 bolts (
A
), in the storage water heater
Do not fully tighten the bolts in order to make it easy to introduce the thermodynamic group, and only
fully secure after the attachment of the group onto the storage water heater.
b)
Aim the metallic structure with the orifices to the three M8 bolts previously mentioned.