background image

 
 
 
 

Eco 250esm / 300esm / 280i / 200p 

 

Assembly and User 

Manual

 

 

 

 

 

 

 
 
 
 
 

Thermodynamic Solar System

  

R0V0

 

Содержание Eco 200p

Страница 1: ...Eco 250esm 300esm 280i 200p Assembly and User Manual Thermodynamic Solar System R0V0...

Страница 2: ...xpansion Tank 7 4 7 Pressure Reducing Valve 7 5 Installation 8 5 1 Panel Fixation 8 5 2 Hot Water Cylinder Installation 9 5 3 Installation of the Thermodynamic Block 9 5 4 Connections 10 5 5 Nitrogen...

Страница 3: ...good solar capture Respect fixing fastening rules Positioning of the hot water cylinder must not be done in The open air In spaces that are potentially explosive due to vapour or liquid gases Do not t...

Страница 4: ...y convection After passing through the panel the Klea fluid is aspirated by the system s mechanical component the compressor which in turn raises the temperature and pressure it is then transmitted to...

Страница 5: ...made shall be handle with care Thermodynamic Solar Panel Width 2000 mm Height 800 mm Thickness 20 mm Weight 8 kg Gross Area Absorver Area 1 6 m The connections to the panel are Flare SAE screw types 3...

Страница 6: ...ned for the panel connections 3 8 Aspiration 1 4 liquid Fig 6 Thermodynamic Block main components The Thermodynamic Block is connected to the hot water cylinder through eight M10 screws 4 4 Fluid R134...

Страница 7: ...or any increase in water caused by a rise in temperature This is the recommended procedure for the correct installation of this equipment Fig 7 Expansion tank installation diagram NOTE Installation of...

Страница 8: ...et maximum benefit from incidental Solar Radiation the panels must be at an inclination of between 10 85 in relation to the horizontal position preferably orientated towards the South It may be instal...

Страница 9: ...Panel types left and right 5 2 Hot Water Cylinder Installation The hot water cylinder shall be installed in a cool and dry location with easy access and protected from all weather conditions The choi...

Страница 10: ...river guaranteeing air tightness The hot water cylinder shall be properly fixed in place at the moment the Thermodynamic Block is positioned thus avoiding any slight drop in the unit considering that...

Страница 11: ...gas to escapes Pipe diameter mm inches Torsion Nm 6 35 1 4 14 18 9 52 3 8 33 42 After finished the connection it must prove that no gas escape exists by applying soap foam on the connections with nit...

Страница 12: ...til the pressure reaches 12 bar Place all the connections under soap foam and verify if the pressure is kept constant 5 6 Vacuum Use only the vacuum pump to remove the air and the humidity from the pi...

Страница 13: ...re aren t any failure problem when starting the system under frost conditions To conclude the installation process it is necessary to connect the electrical cable to the 230V plug socket securing the...

Страница 14: ...next 8 hours Programming Button Factory Only ON OFF Button for Electrical Backup Anti Legionella Button 3 This shall only be turned on an emergency situation to ensure hot water to the user in case o...

Страница 15: ...s power supply Check the electrical cables connection for the control panel Check the system fuses Every time that a LP error occurs the system will have a 20 minutes delay during that period the word...

Страница 16: ...he anode is always dependent of the water quality in each location In areas with raised concentrations of soluble solids the anode needs to be changed with less regularity whereas in situations with l...

Страница 17: ...x working pressure bar Mpa Test pressure bar Mpa Max Operating Temperature C Protection Type Quantity kg Connections piping Type Liquid Line inch Aspiration Line inch Feed V Hz Compressor Fuse A Gener...

Страница 18: ...8 10 DIMENSIONS AND TECHNICAL SCHEMATICS Eco 250esm A B C D E F G H 1 2 3 4 mm inches 70 1050 1450 584 820 350 800 1500 3 4 3 4 3 4 5 4 1 Cold water inlet 2 Recirculation 3 Hot water outlet 4 Magnesiu...

Страница 19: ...sm 300esm 280i 200p Page 19 1 4 3 2 3 2 1 E D H C B A Eco 280i A B C D E H 1 2 3 4 mm inches 260 750 1280 550 800 1650 3 4 1 2 3 4 1 1 4 1 Cold water inlet 2 Recirculation 3 Hot water outlet 4 Magnesi...

Страница 20: ...esm 300esm 280i 200p Page 20 Eco 300esm A B D E F G H 1 2 3 4 mm inches 90 770 680 930 350 850 1580 1 1 1 5 4 3 4 3 2 1 H G F E D B A 4 1 Cold water inlet 2 Recirculation 3 Hot water outlet 4 Magnesiu...

Страница 21: ...1 Eco 200p Wall Hanging A B C D E F G H I J 1 2 3 4 mm inches 180 750 900 800 370 920 280 1250 1030 235 3 4 1 1 4 3 4 Fixation 3 1 4 J I 2 A B C 1 3 2 2 4 H D E F 4 G 1 Cold water inlet 2 Magnesium an...

Страница 22: ...a T Term stato de seguran a 75 C C Compressor R Resist ncia LP Pressostato de Baixa Sonda1 Sonda de temperatura a b Contactos extra Fuse 1 Fus vel Geral Fuse 2 Fus vel Compressor T L N T 230VAC 50Hz L...

Страница 23: ...following indexes o Active chlorine 0 2 ppm o PH 6 Sorensen scale at 25 C o All water has a value greater than the VMA by decree law 74 90 Parts are subject to natural wear and tear levers switches r...