background image

4

www.energeticlighting.com

www.energeticlighting.com

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

2. Disconnect the photocell wire connector and set aside 

the lens front cover (A).

Fig. 2

5

3. Remove the three (3) screws in front of the reflector 

(B) and set the screws and reflector aside.

Fig. 3

5. Hold up the fixture back plate (C) to the junction box 

(not provided) and determine which set of slots line 

up with the mounting screw pattern provided by the 

junction box.  For proper wet location install, ensure 

that silicone gasket (D) is installed between back 

plate (C) and mounting surface.

Ensure that power is shut off and 

connect the supply 

wires to the fixture wires -- black to black, white to 

white, and green to copper/bare.  

WARNING:

 If there is no ground supply wire, stop 

installation and consult a qualified electrician.

Once wire connections are made, secure each with a 

wire nut (AA).

Dimming Connection:

 If fixture is to be connected to 

a dimming system, connect the purple and gray leads 

to its corresponding 0-10v dimming supply leads.  

Otherwise, leaving the fixture 0-10v dimming leads 

open will enable the fixture to run at 100% lumen 

output.

Fig. 5

6. Secure the fixture to the junction box using the 

necessary junction box screws (BB) provided to 

ensure proper mounting and seal around the junction 

box.    

Fig. 6

7. Retrieve reflector (B) and the thre screws previously 

removed in step #3, and re-install the reflector (B) 

onto the back plate (C). 

Fig. 7

B

C

4. For proper installation in a wet location environment, 

peel off each of the adhesive protective layers from 

the silicone gasket (D) and line up the slot pattern to 

the back plate (C) to create a seal when installed onto 

the junction box in the next step.

Fig. 4

C

AA

C

C

BB

C

B

D

D

Peel off adhesive

cover layers

D