EGM-PWML ENERGY METER WITH MEMORY

All brands and logos are registered trademarks of their respective owners

Содержание EGM-PWML

Страница 1: ...USER MANUAL HANDBUCH HANDLEIDING MANUEL DESCRIPTIF EGM PWML ENERGY METER WITH MEMORY...

Страница 2: ...EGM PWML ENERGY METER WITH MEMORY All brands and logos are registered trademarks of their respective owners Energy Meter with memory Energiemessger t EnergieMeter Compteur d nergie avec de la m moire...

Страница 3: ...Software provides basic power consumption readings home use and advanced readings business scientific use Specifications Input 220 240 V AC 50 60 Hz Load max 10 A Power consumption max 1 2W USB 1 1 o...

Страница 4: ...ENERGY METER WITH MEMORY All brands and logos are registered trademarks of their respective owners 1 Indicators and controls of the EGM PW L Figure 1 Socket 1 Load indicator Day Night mode indicator...

Страница 5: ...ckage contents EGM PWML User manual USB cable CD with Power Manager software for Windows 4 Installation of EGM PWML To use EGM PWML please follow next steps 1 Install the software 2 Connect the EGM PW...

Страница 6: ...ode It is offline whenever it is not connected to a PC or when the PC is turned off The device will come online automatically when it is connected to a PC with the Power Manager software running In th...

Страница 7: ...n be viewed and analised with the Power Manager software The software shows different energy characteristics changing over time including the money spent and the power consumption kWh When the softwar...

Страница 8: ...s Push the Device settings button bottom right here to set the device specific options see Figure 3 below Figure 3 In the settings screen you are able to change the name of your device in the Name fie...

Страница 9: ...k the Power meter button see the chapter 7 below 7 Power Meter The Power Meter window can be opened in either a minimized or maximized mode The minimized Power Meter window is shown in Figure 4 below...

Страница 10: ...ENERGY METER WITH MEMORY All brands and logos are registered trademarks of their respective owners Figure 4 Push Maximize button in this window to open the full size Power Meter window see Figure 5 be...

Страница 11: ...ual to explain the physical meaning of these values For most consumers the energy and its cost are the most interesting The Energy E value shows the accumulated energy consumption in watt hours since...

Страница 12: ...trademarks of their respective owners Figure 6 Choose the rate per kWh and currency If you have different rates for peak hours and off peak hours just check the box Use Day Night modes You will then b...

Страница 13: ...of P R Fq Irms Vrms and Cost are continuously logged into the database These readings can be used to build time charts To display the charts just click on the desired value in the Main Power Meter wi...

Страница 14: ...14 EGM PWML ENERGY METER WITH MEMORY All brands and logos are registered trademarks of their respective owners Figure 7 EGM PWML Cost...

Страница 15: ...e the data point density with the Graph details level slider With this slider you actually change the number of points within the chosen time interval for the averaging Fewer points mean less details...

Страница 16: ...EMORY All brands and logos are registered trademarks of their respective owners Tip You can calculate the total energy consumption within a certain period pushing the Calculate button see Figure 8 bel...

Страница 17: ...g tool button and then click with the left mouse button to adjust the scale to the desired level When you select the home tool the chart displays every record from the whole period where the selected...

Страница 18: ...Possible events are Lighting up the indicators in the Power Meter window see Chapter 7 above or run a user specified application To set the parameters for such events see Figure 10 below just push the...

Страница 19: ...sired action from the Action list box If you choose to execute a specific application or program you can select the path to this application in the Path field It is possible to give the event a practi...

Страница 20: ...20 EGM PWML ENERGY METER WITH MEMORY All brands and logos are registered trademarks of their respective owners...

Страница 21: ...21 EGM PWML ENERGY METER WITH MEMORY All brands and logos are registered trademarks of their respective owners...

Страница 22: ...tronikger ten Richtlijnen m b t afvalverwerking Batterijen en accu s dienen als klein chemisch afval afgeleverd te worden bij toegewezen afvalverzamelpunten zie www afvalgids nl U dient ervoor te zorg...

Страница 23: ...The credit note amount will always be calculated on the basis of the current market value of the defective products Die Garantie betr gt 24 Monate ab Verkaufsdatum an den Endverbraucher Das Kaufdatum...

Страница 24: ...e talon de garantie doit num rer clairement la date d achat et le type d appareil Conservez le re u d achat pendant toute la dur e de la garantie car elle est n cessaire pour toute r clamation Au cour...

Страница 25: ...__ ___________________ 20____ _________________________________ ________________________________________________ _____________ _____________ 1 2 3 4 ____________________ __________________________ ___...

Отзывы: