background image

User Manual 

 

 

Page 8

 

5.0 Wiring Diagram 
 

D

X

 B

o

x

2

4

6

X

0

5

X

0

6

X

0

3

X

0

1

5

3

1

R4

+C

+C
Di7

4-20mA
Pressure #2

R

1

R

2

R

3

R

4

C

+

1
2
3
4
5
6
7
8

X

0

5

X

0

3

X

0

4

C001

X

0

2

X

0

1

Ai3

Ai2

+ VDC

Ai1

+ VDC

X

P

M

-T

A

C

2

4

S

1

-1

0

-R

4

-3

3

3

 

C

o

n

tr

o

ll

e

r

2

4

V

a

c

+

+

1

2

1

2

2

1

X

0

3

X

0

1

E

N

L

E

E

N

L

230Vac   10%
115Vac   10%

2

4

V

a

c

0

V

a

c

Aux Fault #1

Ai2

Ai1

Di6

-

-

C002

C003

C004

C005

C006

C012

C013

C014

C015

C016

C017

C018

C019

C011

C020

C021

C022

C023

C024

C025

C032

C030

C031

4-20mA
Pressure #1

4-20mA
System Press.

Ai3

-

+ VDC

not used

Aux Fault #2

Aux Output

V

1

8

1

0

1

2

X

0

2

1

1

9

7

V

2

C028

C029

C026

C027

X

0

4

not used

C015

C025

C024

10k

10k

C016

C023

C013

C014

C022

C027

C029

C031

C021

X

0

7

C019

C018

C017

C011

C008

C007

C001

C002

C003

C004

C005

C006

C010

C009

Multi485

L2
L1

Multi485

L2
L1

C011

1

4

2

8

2

2

2

4

2

6

1

3

2

7

2

1

2

3

2

5

1

6

1

8

2

0

1

5

1

7

1

9

3

0

3

2

2

9

3

1

SEQ

i-

P

C

B

 1

R1

LOAD

GND

Ready/Run

Alarm/Serv.

+20VDC

R2

Di2
Di3

-

6

5

4

3

2

1

SEQ

i-

P

C

B

 2

R1

LOAD

GND

Ready/Run

Alarm/Serv.

+20VDC

R3

Di4
Di5

-

6

5

4

3

2

1

Ao

X

0

6

R

S

4

8

5

A-G ND

C007

C008

L1

C009

C010

L2

X

0

7

Содержание metacentre DX Box

Страница 1: ...MANY0739A GB Metacentre DX Box User Manual TM DX Box bar...

Страница 2: ...tatus Symbols 2 4 Indications 2 5 Compressor Identification 2 6 Operation 2 7 Power Failure Auto Restart 2 8 Failure Modes 2 9 Compressor Fault 2 10 DX Box Fault 2 11 Pressure Sensor Fault 3 0 Parts L...

Страница 3: ...6 wire cable and a compressor interface PCB i PCB The i PCB connections are identical to an system management unit The DX Box also provides optional local pressure sensor connections The compressor de...

Страница 4: ...change from time to time dependant on the set sequencing mode of the management unit In Top Up mode the DX Box will allow variable capacity control as described above dependant on demand In Base Load...

Страница 5: ...esented on the system management unit as compressor number 03 The status of the compressor will also be show using the Run and Load symbols If the Delivery pressure sensor option for a compressor has...

Страница 6: ...Local mode 2 5 Power Failure Auto Restart The DX Box will always automatically start when power is re applied after a power supply disruption or failure 2 6 Failure Modes If communications with the sy...

Страница 7: ...ontroller inputs and outputs E 0135 BAR System Pressure Sensor Fault If one of these fault conditions occur the DX Box will switch off The Run Indicator 9 will also switch off and the Fault Indicator...

Страница 8: ...tem Part No Description 5 Y04CM59 00 Unit i PCB Optional Accessories Item Part No Description 6 Y04CM29 00 Sensor Pressure 4 20mA 0 16 0bar 7 Y01ENER35 00 Module Relay 24Vac 4 0 Technical Data Dimensi...

Страница 9: ...3 C024 C025 C032 C030 C031 4 20mA Pressure 1 4 20mA SystemPress Ai3 VDC notused Aux Fault 2 Aux Output V1 8 10 12 X02 11 9 7 V2 C028 C029 C026 C027 X04 notused C015 C025 C024 10k 10k C016 C023 C013 C0...

Страница 10: ...115V 24Vac 1 isolated 24Vac 2 earthed E E L N N L E BLUE BROWN RED GREEN VIOLET WHITE ORANGE BLACK FH1 FH2 FH3 FH4 FH5 1 VOLTAGE SELECT 2 3 4 X04 2 1 2 X03 X02 X01 T3 15A T1 6A T1 6A T1 0A T1 0A 1 2...

Отзывы: