To access and change these parameters follow the steps below:
1. Press and hold the
button for a few seconds when the unit is in standby mode (i.e. not
busy heating the water). Parameter 0 will flicker.
2. To change this value, press the
button once.
3. Make use of the
or
button to change the value accordingly.
4. Press the
button to confirm the setting.
5. Make use of the
or
button to select between the different operating parameters.
6. To change the values of these parameters, repeat steps 2 to 4.
7. Wait 5 seconds to exit this mode automatically.
Note:
The water temperature measured near the bottom of the water vessel is displayed on the
LCD screen continuously. The temperature displayed will drop as water is consumed and
cold water fills the vessel from the bottom.
If the target temperature needs to be changed, parameter 1 can be modified as explained
above or else the user can simply press the
or
button.
Target Water Temperature
Micro Circulation Function
0 = function off; 1 = function on
Temperature Difference between Target Temperature and
Measured Temperature before Heat Pump Start:
1°C = Heat Pump Starts More Frequently
5°C = Heat Pump Starts Less Frequently