7
©2010 Enerdrive Pty Ltd
Installation
2.4.2 ME-SBC
TM
Wiring Connections - Solenoid Drive
CAUTION: Before connecting any wires, turn off any battery charger and
loads that are connected to the battery banks that the ME-SBC
TM
will be
combining.
Info: If installing in a boat, RV or truck, ensure the conductors passing
through walls, bulkheads or other structural members are protected to
minimize insulation damage such as chafing; which can be caused by
vibration or constant rubbing.
The ME-SBC
TM
should now be mounted, if not please refer to section 2.2. During
installation please refer to Figures 2-6 during the following steps:
1. Unplug the Power Terminal Block from ME-SBC
TM
and ensure the openings
are unscrewed enough to allow the wires to be inserted.
2. Select and connect an appropriately sized red wire
1
from terminal #1 - MAIN
POS (+) on the Power Terminal Block to the positive terminal of the Main Bat-
tery.
3. Select and connect an appropriately sized red with white stripe wire
1
from ter-
minal #2 - AUX POS (+) on the Power Terminal Block to the positive terminal
of the Auxiliary Battery.
4. Select and connect an appropriately sized black wire
1
from terminal #3 - COM
NEG (-) on the Power Terminal Block to the negative busbar or vehicle chas-
sis.
Info: The negative busbar must connect the negative terminals on the
Main and Auxiliary Batteries together.
5. Use an appropriately sized wire
2
to connect each terminal of the solenoid to the
appropriate battery terminal. Please refer to Figure 2-4 for more information
6. Connect one side of the solenoid coil to a positive post on the Main or Auxiliary
Battery or one of the main terminal on the solenoid. Use the appropriate fuse to
protect the wire (2 Amp fast blow maximum). For more information, please consult
the solenoid manufacturers installation instructions.
7. Connect the other side of the solenoid coil to # 4 - SOLENOID (-) on the Ac-
cessories Terminal Block.
8. When all the connections are made and checked, plug the Power Terminal
Block into the ME-SBC
TM
to supply DC power.
9. Immediately after applying DC power, the LED’s on the ME-SBC
TM
should come on
as the unit goes through a power-up self-test. After the initial self-test completes,
the Status LED should be Illuminated. If not, please refer to the troubleshooting
section.
note 1 : The wires connected to #1 - MAIN POS (+), #2 - AUX POS (+) and
#3 - COM NEG (-) should be sized for 30 amp. The battery positive lines should
be protected with a 30 Amp fast blow fuse. Wire size should be appropriate for
the application.
note 2 : The size of this wire will likely be determined by considering the 3%
voltage drop requirements of the charging circuit. Always consult the solenoid
manufacturers installation documentation.
Содержание MagnaSine Smart Battery Combiner ME-SBC
Страница 1: ...ME SBC TM Smart Battery CombinerTM Owner s Manual...
Страница 9: ...2010 Enerdrive Pty Ltd 6 Installation Figure 2 5 ME SBC 25 Amp Combiner Mode...
Страница 11: ...2010 Enerdrive Pty Ltd 8 Installation Figure 2 6 Solenoid Drive...
Страница 13: ...2010 Enerdrive Pty Ltd 10 Installation Figure 2 7 Remote Volt Sense...