background image

5. FAULT INDICATOR

When a fault occurs, LED2(100%)/LED3(75%)/LED4(50%)will blink at the same time.

Blinking 

Frequency

(Every 4 sec)

Fault Cause

Solution

1

The battery is not connected or the 
battery voltage is too low

1) Check battery connection is correct.
2) Check charger connection is correct.
Check each battery is good.

2

Abnormal AC Power Input (Voltage)

1) Check AC input cord is connected between charger and AC 
outlet.
2) Make sure AC plug is tightly inserted into AC outlet.

3

Charger High Temperature Protection

1) Charger shuts down and enters protection mode due to 
charger/environmental temperature is too high. Please place 
the charger in a well-ventilated environment.
2) Disconnect the charger and wait for 15-20mins before 
reconnecting.

4

Battery High Temperature Protection

1) Charger will reduce output current and stop charging when 
the battery temperature exceeds 50°.
2) Disconnect the charger and wait for 15-20 mins before 
reconnecting for charging.

5

Output Current is too large

Return to the factory for repair.

6

Battery voltage is too high

Check and assure that the correct output battery voltage is 
connected.

Page12

Enerdrive ePOWER Industrial Battery Charger Owner’s Manual (Rev. 1.4)

Содержание ePower Industrial EPI-2430

Страница 1: ...Operation Owner s Manual 24V 36V 48V Models Rev 1 4...

Страница 2: ......

Страница 3: ...may result in damage to the unit batteries and or cause harm or serious injury Read manual in its entirety before using the unit and save manual for future reference Product Numbers ePOWER Industrial...

Страница 4: ...o responsibility or liability for losses damages costs or expenses whether special direct indirect consequential or incidental which might arise out of the use of such information The use of any such...

Страница 5: ...E INSTRUCTIONS CONNECTIONS CABLE CONNECTIONS 8 9 5 FAULT INDICATOR 12 6 WATERPROOFING INSTALLATION 13 7 SPECIFICATIONS 14 8 CHARGE PROFILE 15 CHARGE PROFILE INSTRUCTIONS 15 CHARGE PROFILE TABLE 16 9 W...

Страница 6: ...gs on or provided with the battery charger and all appropriate sections of this guide The Enerdrive ePOWER Industrial Battery Charger contains no user serviceable parts Opening up the charger will voi...

Страница 7: ...non rechargeable battery Keep unit away from moist or damp areas Avoid dropping any metal tool or object on the battery Doing so could create a spark or short circuit which goes through the battery o...

Страница 8: ...nlight heat moisture or conductive contaminants Do not install the ePOWER Industrial Battery Charger in corrosive environments When placing the unit allow a minimum of 75mm of space around the unit fo...

Страница 9: ...er to oil dirt mud or direct heavy water spray when cleaning vehicle 2 The enclosure of the charger has been tested successfully to EN60529 meeting IP66 compliance 3 If the detachable AC input power s...

Страница 10: ...s to EPI 2430 EPI 3620 EPI 4815 EPI 4835 to December 2018 Interlock Connection the interlock circuit is a normally closed contact and when AC is applied to the charger this contact will switch to an o...

Страница 11: ...normally open or normally closed circuit with no voltage which change state when the charger is operational Normally open Normally closed Common Image refers to EPI 2430 EPI 3620 EPI 4815 EPI 4835 fro...

Страница 12: ...DC Battery Connection Brake Switch Red Positive Black Negative White Temp Sens When AC has power open circuit When AC has NO power closed circuit Charger Switch Remote LED Open circuit charger ON Clos...

Страница 13: ...Protection 1 Charger shuts down and enters protection mode due to charger environmental temperature is too high Please place the charger in a well ventilated environment 2 Disconnect the charger and...

Страница 14: ...PROOFING INSTALLATION Waterproof ring installation of the AC input cable 1 Slip waterproof ring or grommet over the AC input cable 2 correctly 3 NOTE Take care to not overtighten the waterproof clamp...

Страница 15: ...W Dimensions Weight OperatingTemperature StorageTemperature AGM Flooded GEL Lithium Electronic Protection auto reset Electronic Protection auto reset 100 240V 100 240V 45 65Hz 45 65Hz 850W 3400W 1985W...

Страница 16: ...rt on the front of the charger and insert the USB memory stick 7 Plug the AC power cord into the charger and switch ON AC power 8 Please allow up to 1 min for programming Programming is complete once...

Страница 17: ...GC6A 220D AGM AGM 220 b13 Trojan Trojan T605 Flooded 210 b18 Trojan Trojan T875 Flooded Flooded 170 b19 US US2000 Flooded Flooded 216 b20 US US2200 Flooded Flooded 232 b21 US US250hc Flooded Flooded 2...

Страница 18: ...sible Return and or Repair Policy Ifyouareexperiencinganyproblemswithyourunit pleasecontactourcustomerservicedepartmentatsupport enerdrive com au or Phone 1300 851 535 before returning product to reta...

Страница 19: ...ENERDRIVE PTY LTD P O Box 9159 Wynnum Plaza Queensland Australia 4178 Ph 1300 851 535 Fax 07 3390 6911 Email support enerdrive com au Web www enerdrive com au...

Отзывы: