![Enerdrive B-TEC Lithium EPL-200BT-12V-G2 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/enerdrive/b-tec-lithium-epl-200bt-12v-g2/b-tec-lithium-epl-200bt-12v-g2_owners-manual_2409544008.webp)
FLAT BATTERY
RESET BUTTON
Page 8
Section 6 - Restarting Your Battery
We strongly recommend keeping the battery charged to avoid activating the internal low battery voltage
discconnect.
If your DC system shuts down, the battery may require re-starting. Please use the following procedure:
1.
Turn off all DC and AC Loads
2.
Connect charging source/s and switch ON
3.
Hold the “Reset” button 5 seconds, release and quick press
4.
Release and wait 7 seconds
5.
Power will be restored and charging will commence after a few seconds
6.
When the SOC (State of Charge) is above 20%, loads can be switched on if required
By continuously tripping the low voltage discconnect of the battery you may cause damage to sensitive
electronic equipment that is attached to the battery. i.e. battery chargers, solar controllers, inverters, stereo
equipment etc - all of which are not covered under the battery warranty.
To reconnect, a charge voltage of ≥12.8v must be applied to the battery before the over-discharge release
will activate and allow charge current to flow into the battery. This can be done via a momentary reset switch
between the start battery and B-TEC or by jump starting with a portable power pack.
Follow the above steps to turn off all DC and AC loads, turn on charging sources and then activate reset
switch or apply jump start pack, disconnect as soon as chargers begin charging.
Batteries with Reset Button on Battery
Batteries without Reset Button on Battery
Enerdrive B-TEC G2 Manual (Rev. 3.1)