Precautions

If

 

the

 

air

 

conditioner

 

operates

 

under

 

abnormal

 

conditions,

 

it

 

may

 

cause

 

malfunction,

electric

 

shock

 

or

 

fire

 

hazard.

When

 

turning

 

on

 

or

 

turning

 

off

 

the

 

unit

 

by

 

emergency

 

operation

 

switch,

 

please

 

press

this

 

switch

 

with

 

an

 

insulating

 

object

 

other

 

than

 

metal.

Do not step on top panel of outdoor unit, or put heavy objects. It may cause damage
or personal injury.

Attachment

Installation

 

must

 

be

 

performed

 

by

 

qualified

 

professionals.

 

Otherwise,

 

it

 

may

 

cause

personal

 

injury

 

or

 

damage.

Must follow the electric safety regulations when installing the unit.

According

 

to

 

the

 

local

 

safety

 

regulations,

 

use

 

qualified

 

power

 

supply

 

circuit

 

and

circuit

 

break.

Do install the circuit break. If not, it may cause malfunction.

An

 

all-pole

 

disconnection

 

switch

 

having

 

a

 

contact

 

separation

 

of

 

at

 

least

 

3mm

 

in

 

all

poles

 

should

 

be

 

connected

 

in

 

fixed

 

wiring.

Air conditioner should be properly grounded. Incorrect grounding may cause electric
shock.

Including an circuit break with suitable capacity, please note the following table. Air
switch

 

should

 

be

 

included

 

magnet

 

buckle

 

and

 

heating

 

buckle

 

function,

 

it

 

can

 

protect

the

 

circuit-short

 

and

 

overload.

Don’t use unqualified power cord.

Make sure the power supply matches with the requirement of air conditioner.
Unstable

 

power

 

supply

 

or

 

incorrect

 

wiring

 

or

 

malfunction.

 

Please

 

install

 

proper

 

supply

cables

 

before

 

using

 

the

 

air

 

conditioner.

Properly connect the live wire, neutral wire and grounding wire of power socket.

Be sure to cut off the power supply before proceeding any work related to electricity
and safety.

Do not put through the power before finishing installation.

If the supply cord is damage, it must be replaced by the manufacture, tits service
agent or similarly qualified persons in order to avoid a hazard.

The temperature of refrigerant circuit will be high, please keep the interconnection
cable away from, the copper tube.

The appliance shall be installed in accordance with nation wiring regulations.

Содержание ESC09WMA1A/ES5FX09A

Страница 1: ...HAI VINO ENVIRONMENTAL TECHNOLOGY EQUIPMENT CO LTD please read this owner s manual carefully before operation and retain it for future reference Split Air Conditioner ESC09WMA1A ES5FX09A ESC12WMA2A ES...

Страница 2: ...centrations it will not explode Refrigerants have high flammability Compared to common refrigerants R290 is a nonpolluting refrigerant with no harm to the ozonosphere The influence upon the greenhouse...

Страница 3: ......

Страница 4: ...for a work location All required signs are to be maintained and employers should ensure that employees receive suitable and sufficient instruction and training on the meaning of appropriate safety si...

Страница 5: ...ion drawing 22 Installation prepare 24 Installation Installation of indoor unit 26 Installation of outdoor unit 30 Check after installation 34 Test operation 34 Attachment Configuration of connection...

Страница 6: ...ay water on indoor unit It may cause electric shock or malfunction After removing the filter do not touch fins to avoid injury Do not use fire or hair dryer to dry the filter to avoid deformation or f...

Страница 7: ...rly grounded Incorrect grounding may cause electric shock Including an circuit break with suitable capacity please note the following table Air switch should be included magnet buckle and heating buck...

Страница 8: ...self For the air conditioner with plug the plug should be reachable after finishing installation For the air conditioner without plug can circuit breaker must be installed in the line If you need to r...

Страница 9: ...4 Parts Name Indoor unit Outdoor unit Note Actual product may be different from above graphics please refer to actual products...

Страница 10: ...5 Parts Name Remote controller Display Temp indicator Power indicator ECO...

Страница 11: ...ss button to set your required fan speed auto fan1 fan2 fan3 fan4 fan5 turbo stepless speed 5 Press or button to select fan blowing angle Note During operation point the remote control signal sender a...

Страница 12: ...7 Remote Controller Health button ECO button I feel button I feel ECO...

Страница 13: ...n button can adjust fan speed Press or button can adjust fan blowing angel When selecting cool mode air conditioner will operate under cooling mode Press or button to adjust setting temperature Press...

Страница 14: ...this button can select up down swing angle Fan blow angle can be selected circularly as below Note When convert NO display into status if press this button after 2s swing status directly turns into NO...

Страница 15: ...remote controller ti s the fixed position swing Left right swing louver of air conditioner will stop at the position as shown by the icon to swing There is no this function for some remote control No...

Страница 16: ...me will increase or decrease 0 5 hour Hold or button the time will change quickly until reaching your required time Press Timer to confirm it The word HOUR ON HOUR OFF will stop blinking HOUR ON HOUR...

Страница 17: ...ld plasma generator can effectively eliminate the bacteria and odor in the air 1 The H2O molecules are ionized 2 Neutral reaction between the positive ions and negative ions can eliminate bacterial an...

Страница 18: ...on the low temperature heating function would be canceled In the low temperature heating mode Sleep and Low temperature heating function cannot start at the same time When low temperature heating mod...

Страница 19: ...s dirty it is recommended to use a soft dry cloth or wet cloth to wipe it Note Do not remove the panel when cleaning it Clean filter 1 Open panel Pull out the panel to a certain angle as shown in the...

Страница 20: ...son 1 Check whether air inlets and air outlets are blocked 2 Check whether air switch plug and socket are in good condition 3 Check whether filter is clean 4 Check whether drainage pipe is damaged Cle...

Страница 21: ...please replace them No display when operating remote controller Check whether remote controller appears to be damaged If yes replace it Fluorescent lamp in room Take the remote controller close to ind...

Страница 22: ...er range Adjust temperature to proper range Door and window are open Close door and window Odours are emitted Whether there s odour source such as furniture and cigarette etc Clean the filter Eliminat...

Страница 23: ...information If there are other errors codes please contact qualified professionals for service Error code Name CL Filter clean remind H0 High exhaust temp protection H1 Overcapacity protection H2 Com...

Страница 24: ...ed professionals for service Power cord is overheating or damaged Air conditioner gives off burning smell There s abnormal sound during operation Circuit break trips off frequently Indoor unit is leak...

Страница 25: ...um room area The minimum room area is shown on the nameplate or following table a Leak test is a must after installation Maintenance notes Check whether the maintenance area or the room area meet the...

Страница 26: ...s well ventilated Filling the refrigerant Use the refrigerant filling appliances specialized for R290 Make sure that different kinds of refrigerant won t contaminate with each other The refrigerant ta...

Страница 27: ...22 Installation Drawing...

Страница 28: ...e that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is not yet co...

Страница 29: ...cy devices such as welding machine medical equipment 3 The place near coast area 4 The place with oil or fumes in the air 5 The place with sulfureted gas 6 Other places with special circumstances 7 Th...

Страница 30: ......

Страница 31: ...T4 2X25TA and then check if the frame is firmly installed by pulling the frame If the plastic expansion particle is loose please drill another fixing hole nearly Step 3 Open piping hole 1 Choosing the...

Страница 32: ...40 45 55 60 65 70 75 6 9 52 12 16 19 Step 5 Connect the pipe of indoor unit 1 2 3 4 Note The corresponding moment wrench is needed to connect the piping If other tools are used the pipe will be damag...

Страница 33: ...clip connect the power connection wire to the wiring terminal according to the color tighten the screw and then fix the power connection wire with wire clip 4 Put wiring cover back and then tighten th...

Страница 34: ...pipe should be bound separate at the end Note The power cord and control wire can t be crossed or winding The drain hose should be bound at the bottom Step 9 Hang the indoor unit 1 Put the bound pipes...

Страница 35: ...should be installed at least 3cm above the floor in order to install drain joint For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6...

Страница 36: ...nection wire and signal control wire only for cooling and heating unit to the wiring terminal according to the color fix them with screws 2 Fix the power connection wire and signal control wire with w...

Страница 37: ...than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room Note The through wall height of drain hose shouldn t be...

Страница 38: ...tatus for 1 2min to check if the pressure of piezometer remains in 0 1MPa If the pressure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve compl...

Страница 39: ...cause in sufficient cooling heating capacity Is heat insulation of pipeline sufficient It may cause condensation and water dripping Is water drained well It may cause condensation and water dripping...

Страница 40: ...ing on the length of standard pipe add refrigerant according to the requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter od liq...

Страница 41: ...aper and prevent the burrs from getting into the pipe C Put on suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nu...

Страница 42: ...ts appropriate fire extinguishing equipment shall be available to hand Have a dry powder or CO fire extinguisher adjacent to the charging area No ignition sources No person carrying out work in relati...

Страница 43: ...uate temporary solution shall be used This shall be reported to the owner of the equipment so all parties are advised Initial safety checks shall include That capacitors are discharged this shall be d...

Страница 44: ...of aging or continual vibration from sources such as compressors or fans Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or...

Страница 45: ...Flushing shall be achieved by breaking the vacuum in the system with OFN and continuing to fill until the working pressure is achieved then venting to atmosphere and finally pulling down to a vacuum...

Страница 46: ...l times by a competent person Recovery equipment and cylinders conform to the appropriate standards d Pump down refrigerant system if possible e If a vacuum is not possible make a manifold so that ref...

Страница 47: ...refrigerants In addition a set of calibrated weighing scales shall be available and in good working order Hoses shall be complete with leak free disconnect couplings and in good condition Before using...

Страница 48: ...OOR UNIT kg 9 10 13 5 OUTDOOR UNIT 27 28 33 COPPER PIPE SIZE LIQUID mm in 6 1 4 6 1 4 6 1 4 GAS mm in 9 52 3 8 12 1 2 12 1 2 FUSE T3 15AH 250VAC Interconnection cord H07RN F 3G1 0 H07RN F 3G1 0 H07RN...

Страница 49: ...Unit 3 B Building 4 Zhongdian high tech industrial park 7th technology road Tangjiawan town Xiangzhou District Zhuhai City China ZHUHAI VINO ENVIRONMENTAL TECHNOLOGY EQUIPMENT CO LTD...

Отзывы: