background image

[email protected]

www.ener-j.co.uk

6

Installation Method

Trouble-Shooting

Normal Maintenance 

1.  For the first time to operate the appliance, please fill with the water before bringing power to the appliance.

2.  Turn on the circuit breaker or plug in the socket to bring power to the electric hot water tap. 

3.  In standby mode, the LED display screen light on and display the setting outlet temperature, after 2 seconds, it will display 

the outlet temperature.

4.  Touch   to turn on/off the power of the power of appliance. Press + and – to increase or decrease the outlet temperature.

5.  While rotate handle toward to   the appliance keep closed mode, 

6.  While you rotate the hand shank toward to 

 the cold water will come out; Rotate the knob anti-clockwise, the cold 

water flow will be larger & larger.

7.  Rotate the handle shank to 

 the hot water comes out, Rotate the knob clockwise, the hot water flow will be larger & 

larger, meanwhile the program will mini adjust the working power to reach the setting temperature.

8.  The nozzle is rotatable in 180°

1.  Install a filter in the front-end of water inlet of the electric hot water tap.

2.  Periodically remove scale and dirt that may build up at the sprayer of the tap.

3.  The filter net at the water inlet should be cleaned from time to time. Please turn off the water flow before doing this.

4.  If you will not use this appliance for long time, please disconnect the plug.

WARING: if the outlet temperature can not reach the setting temperature, maybe because the water flow is too high, please 

reduce the hot water flow.

Note: Always turn off the power supply before servicing your unit.

It is not required any regular maintenance. However, to ensure consistent water flow, the following maintenance is 

recommended.

 

1.  Inlet and outlet fittings leaking

  A.   Fittings not tight

  B.   Rubber washer worn-out

A.   Tighten fittings

B.   Replace rubber seal ring

2.  Keep the hand shank in close mode, 

but there is still water come out

  A.   Valve core failure

  B.   Valve body failure

A.   Contact local service

B.   Contact local service

3.  Outlet water flow bifurcate / Outlet 

water flow is too small

  A.   Filter net of bubbler scale or blocked  

         by impurity

  B.   Inlet water pressure is too low

A.   Disconnect the bubbler and clean the  

       filer net. 

B.   Increase the water pressure

4.  There is noisy while turn off the water 

flow

  A.   Water pressure is too high

  B.   Turn off the hand shank too fast

  C.   The water pipe wasn’t fixed well

A.   Turn down the water flow 

B.   Turn off the hand shank again 

C.   Reconnect the pipe

5.  While touch the hot water, hands feel 

a little tingling.

  A.   The appliance is not properly earthed.

A.   Connect the earth line properly

6.  No heating

  A.   No power supply

  B.   The knob didn’t toward to hot water  

         position

  C.   The power board keep off mode

  D.   Manual Reset thermal cut-out cut off

   E.   Heating element failure

A.   Correct power supply 

B.   Toward the knob to hot water  

       position 

C.   Press *** to turn on the power board 

D.   Contact local service

7.  Too high outlet temperature

  A.   Setting temperature is too high

  B.   Thermal Cut-out cut off

A.   Touch “-” to decrease the temperature 

B.   Contact local service

8.  Outlet water flow gest smaller & 

smaller

  A.   Inlet strainer or bubbler was blocked

  B.   Inlet water pressure become lower

A.   Clean strainer or bubbler 

B.   Increase the inlet water pressure

9.  Display E1

  A.   Outlet temperature ≥58°C

A.   Please make sure there is water  

       supply, shut off the power supply  

       then power on again, the E1 will  

       disappear

10. Display E3

  A.   Outlet temperature sensor failure

A.   Replace outlet temperature sensor

Possible Causes

Corrective Actions

Problems

Содержание BW1001

Страница 1: ...onfirm to local codes Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules This appliance must be installed in accordance with the national wiring regul...

Страница 2: ...j co uk www ener j co uk 2 Application Electrical diagram This electric hot water tap is for household use and public It can be used for kitchen sink basin It is not suitable for shower Product Inner...

Страница 3: ...e the appliance is intact and the fittings are complete 2 Please make sure the main power supply water pressure grounding condition ammeter and wire reach the standard of installation requirement 3 Th...

Страница 4: ...B 2 Fig 3 A power cord connect above the table board Fig 3 B Power cord under table board Make the water connection pass through the rubber mat please notice there is a cavity at the rubber mat to fi...

Страница 5: ...ber mat to the inlet connection under table board make sure the rubber mat completely touch the back surface of the table board 5 Fig 6 A power cord connect above the table board Fig 6 B Power cord un...

Страница 6: ...sure consistent water flow the following maintenance is recommended 1 Inlet and outlet fittings leaking A Fittings not tight B Rubber washer worn out A Tighten fittings B Replace rubber seal ring 2 Ke...

Страница 7: ...is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise be caused by the inappropriate waste handling of this product...

Отзывы: