background image

Optimizing Pain Management and Rehabilitation

CTM Controller® 1600

Operating Manual

Important product information. Do not throw away or destroy.

Rév. 1.1 | 2017-12-12

Содержание CTM Controller 1600

Страница 1: ...Optimizing Pain Management and Rehabilitation CTM Controller 1600 Operating Manual Important product information Do not throw away or destroy Rév 1 1 2017 12 12 ...

Страница 2: ...o be used for a period of 10 years when subjected to regular maintenance The CTM Exchanger shall be used for one patient only for the extension of the treatment Table of contents A Important safety information 4 B General safety and usage instructions 5 C Components 6 Control unit 7 Control panel 7 D CTM Controller 1600 setup 8 Connecting the tube and the CTM Exchanger 9 Filling the control unit w...

Страница 3: ...t least 30 cm 12 should be left free on all sides of the device in order to ensure sufficient air circulation The CTM Controller 1600 must be filled with water prior to use See CTM Controller 1600 setup for the instructions for setting up and filling the appliance Before filling with water or emptying the device must always be switched off and disconnected from the power supply Never use caustic o...

Страница 4: ...the water tank Air inlet Handle Mains cable The control panel display symbols Low water level Power Timer Heating Cooling FLASHING Enter Temperature scale Timer On Off Warmer Cooler Enter Temperature scale choice Tube CTM Exchanger Control unit Water level indicator on side Ener C CTM Controller 1600 Operating manual C Components Rev 1 1 2017 12 12 Ener C CTM Controller 1600 Operating manual C Com...

Страница 5: ...through the window of the water tank on the side of the device Avoid the tank overflowing 2 3 to 3 4 full is ideal When the tank is full close it again using the cover As soon as the tank has been filled connect the mains cable to a suitable socket and press the ON OFF button to switch the device on The control unit then pumps the water through the tube and the CTM Exchanger which may lead to the ...

Страница 6: ...r to re establish the flow remove the CTM Exchanger from the body and set the temperature to 42 C 108 F for about 7 to 10 minutes The flow of water should then be re established and you can restart the cold therapy WARNING Too long application of cold can lead to frostbites and to local skin damages up to tissue necrosis Recommended procedure for therapeutic heating NOTE always follow the therapy ...

Страница 7: ...customer service Switch the device off and pull out the mains plug Wait for 15 minutes switch the device back on and enter the desired temperature If the Problem occurs again note the error message pull out the mains plug and call customer service Cleaning the control unit Switch the device off and pull out the mains plug Use a clean damp cloth to clean the outside of the control unit Only use mil...

Страница 8: ...ste Electrical and Electronic Equipment WEEE Symbol Product owners should refer to their specific state and government regulatory guide lines for proper disposal NOTE Choose the correct size of the exchanger to completely cover the area to treat with the pad where water circulates Cleaning the CTM Exchanger The CTM Exchanger can be cleaned by wiping the plastic surface with a mild washing up liqui...

Страница 9: ...n an environment as described below Table 2 for Transient Electromagnetic Immunity Immunity Test Electrostatic Discharge ESD EN 61000 4 2 Radiated RF EN 61000 4 3 Electrical Fast transient EN 61000 4 4 Surge EN61000 4 5 Conduct disturbances EN 61000 4 6 Power frequency magnetic field 50Hz 60Hz EN 61000 4 8 Voltage dips short interruptions and voltage variations on power supply input lines IEC 6100...

Страница 10: ...0 V m 80 MHz to 800 MHz E2 10 V m 800 MHz to 2 5 GHz NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radi...