background image

 

15 

MODE   

Select alarm and MD/EXT mode.  

 

 

 

(OFF/MD/EXT/ MD+EXT) 

AREA SEL 

Select MD area number. (1~4) 

 

 

Select MD enable/disable. 

DEFAULT 

Set MD area as default. 

ADJ TOP/LEFT 

Adjust the location of the MD area with boundary top and left.

 

ADJ BOT/RIGHT 

Adjust the location of the MD area with boundary bottom and right. 

SENSITIVITY 

Adjust sensitivity of MD area. (MD:1~10)

 

DWELL TIME 

Dwell time setup of zoom preset. (10,20,...,180sec) 

ALARM MODE 

One of two options can be selected for EXT mode. BW/PRESET.

 

PRESET SEL 

Select zoom preset number. (0FF,1~10) 

 

 

(When the MD and/or Alarm is/are occurred.) 

 
 

 
 
5.2.6 PRIVACY 
 
 
 
 
 
 
 
 
 
 
 
 

 

MASK SEL

 

Select mask area number. (1~16) 

   

 

 

Select mask enable/disable.  

DEFAULT

 

Set mask area as default. 

ADJ TOP/LEFT

 

Adjust the location of the mask area with boundary top and left. 

ADJ BOT/RIGHT

  

Adjust the location of the mask area with boundary bottom and  

 

 

 

right. 

COLOR 

 

Select mask color. (1~8)  

MOSAIC

 

Mosaic display on/off.  

MOSAIC TYPE

 

Mosaic roughness setting. (1 ~ 4) 

 
NOTE1 : The mosaic when the color is transparent, is possible 
 
 

Содержание VKC-1416C

Страница 1: ...Operating Instructions 1 4 Day Night Autofocus Camera VKC 1416C...

Страница 2: ...id or solid object fall into the cabinet unplug the unit and have it checked by qualified personnel before operating it any further Unplug the unit from the wall outlet if it is not going to be used f...

Страница 3: ...L MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS OPERATION OF THIS EQUIPMENT IN A RESIDENTIAL AREA IS LIKELY TO CAUSE HARMFUL INTERFERENCE IN WHICH CASE THE USER WILL BE REQUIRED TO CORRECT TH...

Страница 4: ...om being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use on...

Страница 5: ...Connection 9 4 1 COLOR LEAD WIRE COLOR DISPLAY LABEL 9 4 2 EXTERNAL INPUT 10 4 3 EXTERNAL OUTPUT 10 4 4 RS 485 CONNECTION 10 4 5 EXTERNAL LENS CONTROL 11 4 6 EXTERNAL A D KEY CONTROL 11 5 CAMERA ADJU...

Страница 6: ...DC 12V CAUTION Use Certified Listed Class 2 power source only Use at the 12VDC Adapter must provide the power consumption of above 500MA Function D N Day Night DSS Digital Slow Shutter DIS Digital Im...

Страница 7: ...l local national electrical and mechanical codes must perform installation of the camera Perform the following steps to install the camera 2 1 PACKAGE CONTENTS Camera 1EA Instruction Manual This docum...

Страница 8: ...8 3 Parts Name Function...

Страница 9: ...N CAUTION Do not connect the power cable until all other connections have been completed If you complete the whole connection of cameras then you have to cut the extra cable 4 1 COLOR LEAD WIRE COLOR...

Страница 10: ...to below in detail 1 EXT OUT output voltage The EXT OUT lead output voltage for COLOR and B W is as following EXT OUT COLOR 0V B W 5V 2 MD OUT output voltage The MD OUT lead output voltage is as foll...

Страница 11: ...11 4 5 EXTERNAL LENS CONTROL 4 6 EXTERNAL A D KEY CONTROL External Controller Circuit Schematic...

Страница 12: ...1 0 1 5 2 5 6m D ZOOM Digital Zoom on off D ZOOM END Select maximum Digital Zoom magnification x2 x3 x4 x6 x8 x12 x16 ZOOM PRESET Select zoom preset number Default is x1 1 10 SET PRESET Set the zoom...

Страница 13: ...lance mode OUTDOOR Outdoor white balance mode MANUAL Manual mode You can change R and B Gain manually CRS Color rolling suppression mode R GAIN Adjust R gain value 0 255 B GAIN Adjust B gain value 0 2...

Страница 14: ...Digital slow shutter on off MAX DSS Select maximum slow shutter value x2 x512 FLICKERLESS Flickerless on off BRIGHTNESS Adjust brightness level 0 50 IRIS SPEED Sets the convergence speed of the mecha...

Страница 15: ...0 20 180sec ALARM MODE One of two options can be selected for EXT mode BW PRESET PRESET SEL Select zoom preset number 0FF 1 10 When the MD and or Alarm is are occurred 5 2 6 PRIVACY MASK SEL Select ma...

Страница 16: ...the opposit if there is no motion DNR level is raised and noise will be decreased WHITE DET Press the Menu key to execute the White Pixel Detection function and then the Iris will be closed automatica...

Страница 17: ...Title and ID display 2 Camera Title and ID Zoom lens position display TITLE Select camera title menu A Z 0 9 ALARM TEXT If the alarm is occurred the ALARM TEXT established at this menu will be display...

Страница 18: ...he lens dirty If so clean the lens with a soft clean cloth The camera is not working properly and the surface of the camera case is hot Is the camera connected to the proper power The contrast on the...

Страница 19: ...19 7 DIMENSIONS...

Страница 20: ...n Detection Off MD EXT MD EXT DIS Digital Image stabilizer On Off DSS Digital Slow Shutter x2 x512 DNR Digital Noise Reduction 2D 3D PM Privacy Masking 1 16 zone AWB Auto White Balance AWB WAWB Indoor...

Страница 21: ...ure Ratio F1 6 wide F3 7 tele Angle of View Horizontal 49 5 degree wide 2 4 degree tele Power Input 3 pin terminal block Video Output BNC connector Operating Temperature 10 50 Operating Humidity 0 96...

Страница 22: ...distribution through specialised trade channels only Videor E Hartig GmbH Carl Zeiss Stra e 8 63322 R dermark Germany Tel 49 0 6074 888 0 Fax 49 0 6074 888 100 www videor com Technical changes reserv...

Отзывы: