38
5.2 Flush Mount
Quick installation guide
. Locate the mounting template at the installation
position and drill the ceiling or wall if needed.
. Open bubble by loosening ring cover fixing screws (j)
(3x).
CAUTION
Extreme care should be taken NOT to scratch the
dome surfaces and to protect it from dirt or dust at
any time.
3. Place dome base on pre-drilled position and fix it
through mount holes (f) (3x) by using mount screws (7).
(Use three screws only out of mount screws (7) (4x).)
4. Route the power/video cable to the connecting place.
CAUTION
Care should be taken the cable is NOT to be
damaged, kinked or exposed in the hazardous area.
5. Set the camera’s angle (Pan, Tilt, inclination).
6. Adjust Zoom & Focus (a) by using focus adjust driver (4).
7. Put bubble over dome base and tighten ring cover fixing
screws (j) (3x) by using L-shape star wrench (3).
CAUTION
Tighten enough ring cover fixing screws (j) (3x) so
that there should be NO gap between lens hood (b)
and clear bubble (i) to avoid the light inflow from
IR LEDs.
Ceiling or wall
Mount screws (7)
Dome base
Bubble
L-Wrench
5.3 Setup of the Zoom and FOCUS
• Remove the bubble and power up the camera.
• Adjust Zoom setting (a) using focus adjust driver (4).
• Adjust Focus setting (a) using focus adjust driver (4).
• Close the bubble and tighten ring cover fixing screws (j) (x3) using L-shape hex wrench (3).