Install the mount onto a strong structure.
Prepare the Junction box base and the accessaries for installation.
1. Locate the mounting template at the installation position and drill the ceiling or
wall if needed.
2. Route the Power/Ethernet cables through the grommets from the wall. Insert the
grommets onto the Junction box base.
3. Place the Junction box base on pre-drilled position and fix it through using
mounting screws (4x30mm).
Using Grommet
Tear off the cocks of grommets properly and pull up the grommet so that sealing can
wrap the cable properly as illustrated. If it doesn’t wrap the cable properly,it could cause
the water leakage problem.
Using RJ45 Easy Cap for Network cable
Recommended cable length into the Junction box base
• CABLE with RJ-45 Connector: 70mm~80mm
• CABLE for Network Wiring Connector: 20mm~30mm (excluding cable tripping
section) 8P cable stripping distance: 20mm~30mm
• Alarm/Audio CABLE: 20mm~30mm (excluding cable tripping section)
6P cable stripping distance: 20mm~30mm
3. ALARM-IN
4. ALARM-OUT
5. GND
Connections to Alarm connectors