Installation Instructions
09
Cover Opening(Sabotage) Alarm and External Alarm Input are electrically tied
together internally.
Alarm contact types, N.O or N.C are selectable by the Alarm Input Selection
Jumper and the selection types should be matched with Alarm Type in setup
menu.
When both of Cover Opening Alarm and External Alarm Input are used at the
same time, the alarm contact types must match. Otherwise, alarm malfunctions.
When External Alarm Input only is used with disabling Cover Opening Alarm,
remove the jumper cap of Alarm Input Selection Jumper.
Default setting for Alarm Input selection jumper is N.C. It prevents from Alarm is
generating when Junction box is OPEN during installation. Alarm Input selection
jumper should be set to N.O and Event Trigger/Action should be dened to enable
Cover opening alarm.
For Cover Opening Alarm, please go to SETUP> Event Rules> Event Processing>
Add Event Trigger should be set to “Alarm In” and then Event Action should be
set as available options.
• Cover Opening Alarm and External Alarm Input :
CAUTION
N.O : Alarm is generated when Junction box is OPEN.
N.C : Alarm is generated when Junction box is CLOSED.
[N.O]
[N.C]
Cover opening alarm switch
(Sabotage alarm)
Alarm Input selection jumper
MEGA-PIXEL NETWORK CAMERA
Содержание 220592
Страница 1: ...EN User Manual 1 2 5 Network Camera 3840x2160 Day Night DOL WDR 3 6 11mm infrared IP67 ICB 68M3611M5A ...
Страница 2: ......
Страница 30: ...Full Menu Setup 30 MEGA PIXEL NETWORK CAMERA 3 2 4 Image 2016 10 06 09 50 35 CAM1 50 50 50 50 50 50 50 5 ...
Страница 55: ...55 MEGA PIXEL NETWORK CAMERA Full Menu Setup ...
Страница 67: ...67 MEGA PIXEL NETWORK CAMERA Full Menu Setup ...
Страница 76: ......
Страница 77: ......
Страница 78: ......