Fig. 12: Locations of cable entry points in Enelion Wall-
box Adspace.
The removal of plugs for the assembly of cable glands
should be performed according to the following guide-
lines:
1. place the device on a stable surface,
2. use a hammer and a flat-bladed screwdriver to
knock out the gland hole plug carefully.
The cable glands in the upper part of the device should
be put into the holes in the lower part of the device
and screwed to ensure tightness. The gland nut re-
quires a 32 mm, spanner and the gland requires a
30 mmspanner.
After repositioning the glands, the
openings in the upper part of the device should be
closed with the plugs provided with the product.
The cable gland for communication cables should be
installed in accordance with the manufacturer’s instruc-
tions.
o
WARNING
If the gland is repositioned by the user, the man-
ufacturer’s warranty for the tightness of the de-
vice in accordance with the IP54 class becomes
void. Correct performance of the operation en-
sures adequate tightness; however, the manu-
facturer reserves the right to refuse to repair un-
der warranty the damage resulting from the re-
location of the cable gland from the top to the
bottom of the device.
4.4.
Mounting the device
INFO
The device has been equipped with a template
facilitating the installation.
1. Determine the final location of the device using
the attached template and the level and mark the
mounting holes. The template marks the mount-
ing holes, the outline of the rear wall of the device,
the axes of the glands (both in the version with a
gland in the upper and lower part of the device)
and the optimal cable lengths. Mounting holes
should be at least 5 cm from the edge of the wall
(in case of a recess, leave enough space on both
sides of the device to reach with the Allen key).
The axis of the power cables must coincide with
the axis of the glands marked on the template.
Make sure that the power cord:
• of the right socket is at least 300 mm long,
• of the left socket is at least 1000 mm long,
when measured from the edge of the device
marked on the template.
2. Make assembly holes and install expansion bolts.
Mounting holes should be made in accordance
with the specification of expansion bolts which
should be placed in the cleaned holes.
3. Make sure that there is no voltage in the power
cord.
4. Open the appliance as described in section
Opening and closing Enelion Wallbox Adspace
5. Put the device in the target position by threading
the power cables through the glands.
6. Fasten the device with screws using a screw-
driver with a shaft length of at least 150 mm.
7. Screw on the power cable glands ensuring tight-
ness.
8. (Optional) Insert at least 300 mm of the commu-
nication cables into the device.
The device mounted in this way can be connected.