TROUBLESHOOTING
CONDITION
CAUSE
REMEDY
Pump will not
prime
1)
Insufficient motor
RPM
2)
Air leak on suction
plumbing
3)
Blocked/Restricted
intake hose
4)
Filter cap disen-
gaged
5)
Filter gasket
damaged/missing
1)
Increase motor
RPM until pump
primes
2)
Tighten/replace fit-
tings & hose clamps.
Verify suction hoses
are in good condition
3)
Remove blockage
from suction line,
ensure line is not
kinked
4)
Lock filter cap into
position
5)
Replace filter gas-
ket
Pressure drops/
fluctuates during
standard
operation
1)
Restriction on suc-
tion line
2)
Pump sucking air
3)
Plugged filter
4)
Damaged regulator
1)
Inspect tank and
suction lines and
remove restriction
2)
Tighten fittings
3)
Remove and clean
filter mesh and hous-
ing
4)
Remove regulator
stem and inspect for
broken parts/pieces
Pressure gauge
not registering
1)
Plugged with debris
1)
Unthread, check
and clean pressure
gauge
Содержание FIELD BOSS XSTREAM SFB060FG290EX
Страница 32: ...32 Field Boss Xstream English SFB100FG290EX...
Страница 34: ...34 Field Boss Xstream English DETAIL VIEW A 44 28 26 31 4 30 41 3 8 29 2 27 30 25 12 DETAIL A...
Страница 39: ...39 Version 1 9 English SFB100FG290EX ES...
Страница 41: ...41 Version 1 9 English VIEW A 4 3 9 7 29 8 26 37 10 36 38 39 6 27 64 30 28 23 22 DETAIL VIEW A...