Operate power generator ESE 604 DHG DIN
38
ESE 604 DHG (ES) DIN
Status: October 2018
WARNING!
Exhaust gases can cause fatal asphyxiation.
Provide for sufficient ventilation.
Use an exhaust gas pipe.
Only operate the generator outdoors.
WARNING!
Hot parts can ignite flammable and explosive materials.
Avoid flammable materials at the operating site.
Avoid explosive materials at the operating site.
WARNING!
Heat or moisture destroys the device.
Avoid overheating (sufficient ventilation).
Avoid moisture.
Start the engine as follows:
Fig. 4-2: A hand start
1.
Push the choke lever
❶
) to the far left (completely
for a cold engine / appropriately less for a warm engine).
2.
Push the lever on the fuel valve
❷
) up to the right
stop.
3.
Place the engine switch
❹
)
in Pos. “I“.
Starting the motor
HAND START
1
2
3
4