Status at:
February 2013
ESE 807 / 1107 / 1307 / 1407 DBG (ES) DIN
41
Connecting up to consumers
4.6
Proceed as follows to connect appliances to the generator.
The following requirements must be met:
generator has been started (see 4.4)
protective earthing conductor tested (see 4.7)
device switched off
WARNING!
Electric shocks cause injury or death.
Do not earth the generator (except for special option FI).
Do not connect protective conductor to an existing po-
tential equalisation line.
Do not connect the generator to an existing electrical
grid.
You can connect devices using Schuko or CEE sockets.
Fig. 4-3: Connecting up to consumers
Requirements
Connecting up to
consumers