TopClean S CPC 30
6 Commissioning
Hauser
43
Hold function = "Freezing the outputs"
The current outputs can be "frozen" for each menu. This means that the value which you
define in this menu is output. With hold, "Hold" appears in the display.
The hold function can also be activated externally via the hold input (see wiring diagram
on page 15, digital input E1). The on-site hold has a higher priority than an external hold.
!
Note!
•
If a hold is active, no programme can be started.
If current output 2 is configured for the controller, it complies with the controller hold (see
Field I5).
PARAM
⇒
Set up 1
⇒
Hold
CODE
CHOICE
(default = bold)
INFO
(E1, 2 = Editor types, s. page 28)
User
settings
I1
CAL
DIAG
PARAM
CPC
on
on
on
on
Selection: Automatic hold active when:
CAL
= Calibration
DIAG = Service/diagnosis
PARAM
= Parameter entry menu
CPC on
: If programme runs, Hold is active. If CPC Hold
"off" is selected, no Hold will be set from the CPC 30.
User
settings
I2
Last
Set
Min (0/4 mA)
Max (22 mA)
Select the current for hold
Last
= The current value is "frozen"
Set
= The value set in Field I3 (below) is output in a
hold.
Min / Max
= The minimum and maximum current value
is output.
E2
I3
000%
(0 ... 100%)
Enter Hold current
(only for Set)
Number settable from 0% = 0/4 mA to 100% = 20 mA
E1
I4
010 s
(0 ... 999s)
Enter hold delay time
The hold remains active for the given hold delay time
after leaving the CAL, PARAM, DIAG menus. During the
hold delay time, the "Hold" indicator flashes in the
display.
E2
I5
Freeze actuating variable:
Yes
No
Controller hold
Freeze actuating variable (dosing) :
Yes
: During an active hold, the last actuating variable is
output.
No
: During a hold, no dosing takes place. PWM or PFM
relays remain in the dropped-out state. An actuator
drive is controlled until it is closed.
!
Note!
If the set value is output via an actuating variable with
feedback, the actuator remains active. It also reacts in
the hold should the position suddenly change.
E2