22
Soliwave FDR16/FQR16
Hauser
Operation options
7.1
Light signals (LEDs)
Display
Meaning
Operation
LED lights up: Device is ready for operation (supply voltage is
applied)
LED flashes: Device is in parameterization mode → 23
Error/Warning
LED lights up: Error/device failure (unrecoverable error)
LED flashes: Warning/maintenance required (recoverable error)
Sensor state
LED off: Free path
LED on: Covered path
For parameterization only
Signal strength
The signal strength is indicated by a white LED, the light state (off,
2 to 15 Hz or permanently lit) is proportional to the strength of the
signal.
7.2
Output signal
7.2.1
Point level detection
Point level
Signal strength (LED white)
Sensor state
Switching output
MAX safety
MIN safety
LED on or flashing fast
(approx. 9 to 15 Hz)
1
2
4
1
LED off or flashing slowly
(approx. 2 to 8 Hz)
2
1
1
4
7.2.2
Error case
Point level
Sensor state
Error/Warning
Switching output
Warning
LED flashing
1
2
4
1
2
1
1
4
/
Error
LED lights up
permanently
2
1
4
1
Содержание Soliwave FDR16