![Endress+Hauser Soliswitch FTE20 Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/endress-hauser/soliswitch-fte20/soliswitch-fte20_operating-instructions-manual_2408469011.webp)
Soliswitch FTE20
Installation
Hauser
11
mm (in)
6
7
8
A0017074
å
3
Incorrect installation positions of the point level switch
6:
In direction of solids flow
7:
Installation coupling too long
8:
Horizontal with shaft length >300 mm (11.8 in)
Ambient temperature range
–20 to 60 °C (–4 to 140 °F)
Medium temperature range
–20 to 80 °C (–4 to 176 °F)
More information is provided in the "Technical data" section (
4.3
Installation instructions
NOTICE
The device can be damaged if handled incorrectly during installation
►
Do not turn the housing to tighten the process connection. Once the process connection has
been tightened, the housing can be aligned so that the cable entries point downwards.