Soliswitch FTE20
Technical data
Hauser
23
2. Wait for the error detection time to elapse (approx. 25 s).
Ã
If no rotational movement is detected during the error detection time, the device
signals the full or empty alarm again and the light in the electronics housing flashes.
9
Technical data
9.1
Input
9.1.1
Measured variable
Level (in line with the orientation and length)
9.1.2
Measuring range
The measuring range depends on the installation location of the Soliswitch FTE20 and the
selected length of the shaft 75 to 300 mm (2.95 to 11.81 in) or the rope extension up to max.
2
000 mm (6.56 ft).
9.2
Output
9.2.1
Output signal
Binary
9.2.2
Switching output
Function
Switch a floating changeover contact.
Switching behavior
On/off
Switching capacity
• Max. 230 V AC, 6 A / cos phi =1
• 50 V DC, 1 A
• Min. switching load 300 mW (5 V/5 mA)
9.3
Power supply
9.3.1
Terminal assignment
*
Protective ground
N (AC),
L- (DC)
Power connection
L1 (AC),
L+ (DC)
Power connection