• To maintain IP66 housing protection, install the housing cover, cable
entries and plug-in connectors correctly. During operation, screw on
cover until the stop and tighten securing clamp on cover.
• Seal unused entry glands with approved sealing plugs that correspond
to the type of protection. The plastic transport sealing plug does
not meet this requirement and must therefore be replaced during
installation.
• Only permanently routed cables and lines may be introduced or con-
nected. The operator must provide suitable strain relief. Observe the
maximum thermal load of the cables and lines introduced.
Safety instructions:
Zone 20
• In the event of potentially explosive vapor/air mixtures, operate the
device only under atmospheric conditions.
• Temperature:
- FTR16: -20 to +60 °C (-4 to +140 °F)
- FTR20: -40 to +70 °C (-40 to +158 °F)
• Pressure: 0.5 to 6.8 bar (7 to 99 psi)
• If no potentially explosive mixtures are present, or if additional
protective measures have been taken, the device may also be ope
-
rated under non-atmospheric conditions in accordance with the
manufacturer's specifications.
• Only use the device in media to which the wetted materials have
sufficient durability.
Connection data
Device type FTR16
Connection socket/pin
Connection data
1, 2 (supply voltage)
U ≤ 30 V DC
I ≤ 60 mA (without load)
P ≤ 1.1 W
3, 4 (3-wire PNP)
I ≤ 200 mA
Device type FTR20
Terminal
Connection data
1, 2 (supply voltage)
U
≤
253 V AC
U
≤
30 V AC / 60 V DC
3, 4, 5 (relay)
U
≤
250 V AC / 4A,
125 V DC / 0.4 A or
30 V DC / 4 A
3, 4 (4-20 mA)
R
L
≤
600
Ω
3, 4 (solid-state relay)
U
≤
30 V AC or 40 V DC
I ≤ 0.4 A