About this document

Smart System for Aquacultures SSP200B

6

Hauser

1.4  

Acronyms used

Acronyms

Meaning

AC

Alternating Current

CAS40D

Hauser ammonium and nitrate sensor

CM444

Hauser transmitter

COS51D (only SSP200B for salt water
applications)

Hauser oxygen sensor

COS61D (only SSP200B for freshwater
applications)

Hauser oxygen sensor

CYA112

Hauser immersion assembly

CYK10

Hauser measuring cable

CPU

Central Processing Unit

DC

Direct Current

SSP

Smart System Package

Rest JSON API

Specification for REST-compliant API (Application Programmable
Interface) (REST = Representational State Transfer)

1.5  

Documentation

The Operating Instructions for the Smart System are included in the delivery.

Supplementary documentation for SSP Smart Systems and system components

System or system components

Designation

Documentation

Smart System for Surface Water

SSP100B

• Technical Information TI01550S/04/EN
• Operating Instructions BA02044S/04/EN

Smart System for Aquacultures

SSP200B

• Technical Information TI01551S/04/EN
• Operating Instructions BA02045S/04/EN

Modbus Edge Device

SGC400

Technical Information TI01422S/04/EN

Transmitter

Liquiline CM444 • Technical Information TI00444C/07/EN

• Brief Operating Instructions KA01159C/07/EN
• Operating Instructions BA00444C/07/EN
• Installation Instructions EA00009C/07/A2

Ammonium and nitrate sensor

ISEmax CAS40D • Technical Information TI00491C/07/EN

• Operating Instructions BA00491C/07/EN

Oxygen sensor (for SSP200B for salt
water applications)

Oxymax COS51D • Technical Information TI00413C/07/EN

• Brief Operating Instructions KA00413C/07/EN
• Operating Instructions BA00413C/07/EN

Oxygen sensor (for SSP200B for
freshwater applications)

Oxymax COS61D • Technical Information TI00387C/07/EN

• Brief Operating Instructions KA01133C/07/EN
• Operating Instructions BA00460C/07/EN

Immersion assembly

Flexdip CYA112 • Technical Information TI00118C/07/EN

• Operating Instructions BA00118C/07/A2

Measuring cables

CYK10

• Technical Information TI00432C/07/EN
• Operating Instructions BA00432C/07/EN

For additional documentation, please refer to the Hauser Operations App or

go to 

www.endress.com/device-viewer

.

Содержание Smart System SSP200B

Страница 1: ...Products Solutions Services Operating Instructions Smart System for Aquacultures SSP200B Package with smart sensors for monitoring water quality in aquacultures BA02045S 04 EN 01 20 71484907 2020 06 01 ...

Страница 2: ...vision history Smart System for Aquacultures SSP200B 2 Endress Hauser Revision history Product version Operating Instructions Changes Comments 1 00 XX B02045S 04 DE 01 20 Initial version Replaces BA01930S ...

Страница 3: ...lies CYA112 15 5 4 Post installation check 16 6 Electrical connection 17 6 1 Safety 17 6 2 Opening and closing the housing 17 6 3 Cable entries and terminals 18 6 4 Electrical connection Liquiline CM444 18 6 4 1 Cable mounting rail 19 6 4 2 Connecting the Liquiline CM444 supply voltage 19 6 4 3 Connecting the sensors 20 6 5 Electrical connection of Modbus Edge Device 21 6 5 1 Preparing the Modbus ...

Страница 4: ...ilure to avoid this situation can result in serious or fatal injury CAUTION CAUTION This symbol alerts you to a dangerous situation Failure to avoid this situation can result in minor or medium injury NOTICE NOTE This symbol contains information on procedures and other facts which do not result in personal injury 1 2 2 Symbols for certain types of information Symbol Meaning Permitted Procedures pr...

Страница 5: ...ccurred Symbol as per NAMUR NE107 Out of Specification Medium severity level Either the permitted ambient conditions or the permitted process conditions have been exceeded or the measured errors are too large Symbol as per NAMUR NE107 Maintenance Required Low severity level The output signal is still valid The expected operating life is nearly exhausted or functionality will soon be restricted Wit...

Страница 6: ...Smart System for Aquacultures SSP200B Technical Information TI01551S 04 EN Operating Instructions BA02045S 04 EN Modbus Edge Device SGC400 Technical Information TI01422S 04 EN Transmitter Liquiline CM444 Technical Information TI00444C 07 EN Brief Operating Instructions KA01159C 07 EN Operating Instructions BA00444C 07 EN Installation Instructions EA00009C 07 A2 Ammonium and nitrate sensor ISEmax C...

Страница 7: ...Modicon Incorporated RUT240 is a product of Teltonika Ltd 08105 Vilnius Lithuania RevPi Core 3 is a product of Kunbus GmbH 73770 Denkendorf Germany UNO PS is a product of Phoenix CONTACT GmbH Co KG 32825 Blomberg Germany All other brand and product names are trademarks or registered trademarks of the companies and organizations in question ...

Страница 8: ...he Liquiline CM444 transmitter is a multichannel controller and is used to connect the digital sensors supplied Any other use is considered to be non designated use Designated use entails compliance with the operating and maintenance requirements specified by the manufacturer The Smart System must be mounted in an environment intended for this purpose The Smart System is not suitable for use in ex...

Страница 9: ...iginal spare parts and accessories from Endress Hauser only 2 5 Product safety The components used for the Smart System meet the general safety standards and legal requirements Furthermore the components comply with the EC EU Directives that are listed in the EU Declarations of Conformity for the components 2 6 IT security We only provide a warranty if the system is installed and used as described...

Страница 10: ...transmits the device ID data measured values and status information to the Netilion Cloud The data sent to the Netilion Cloud can be either queried directly via a REST JSON API or used in a smartphone application 3 2 System design 1 2 3 4 5 6 1 Network architecture 1 Field device e g Liquiline CM444 2 Modbus TCP connection 3 Modbus Edge Device SGC400 4 LTE connection 5 Netilion Cloud 6 User applic...

Страница 11: ... number of the Liquiline CM444 transmitter Serial numbers of the sensors Discount code for registering the installation in Netilion Cloud 11111105G00 12345678 11111105O00 11111105I10 Assembled in Switzerland CH 4153 Reinach Discount Code Endress Hauser Extended order code R1000224820 Order code Process Solutions AG Serial No ISEmax CAS40D Serial No Liquiline CM444 Serial No Oxymax COS61D Serial nu...

Страница 12: ...nsport The components are packed in such a way that they are fully protected against shock when in storage and during transportation The permitted storage temperature is 0 to 40 C 32 to 104 F Store the components in the original packaging in a dry place Where possible only transport the components in the original packaging ...

Страница 13: ... IP66 67 Modbus Edge Device SGC400 IP54 5 2 Liquiline CM444 and Modbus Edge Device 5 2 1 Mounting the Liquiline CM444 and the Modbus Edge Device Mount both the Liquiline CM444 transmitter and the Modbus Edge Device on the wall using a mounting plate For detailed information on the dimensions see the Technical Information for Liquiline CM444 and the Technical Information for Modbus Edge Device Take...

Страница 14: ...the installation clearances indicated The diameter of the boreholes depends on the wall plugs used Wall plugs and screws are not included in the delivery 2 Hook the device into the holder 3 Push the device down into the holder until the device clicks into place 5 2 2 Disassembling the Liquiline CM444 and Modbus Edge Device Disassemble the Liquiline CM444 transmitter and the Modbus Edge Device in t...

Страница 15: ...e front 5 3 Assembling immersion assemblies CYA112 Note that the immersion assemblies are fitted with different sensor adapters The following sensors are mounted with the immersion assembly CYA112 SSP200B for salt water applications oxygen sensor COS51D with NPT3 4 sensor adapter SSP200B for freshwater applications oxygen sensor COS61D with G1 sensor adapter The ammonium and nitrate sensor CAS40D ...

Страница 16: ...g 4 Mount the multifunctional clamp ring on the immersion tube Make sure to keep a distance of 60 to 80 mm from the upper edge of the immersion tube as illustrated in the graphic above 5 If the sensor is not fitted with a permanently attached sensor cable connect the measuring cable supplied to the sensor 6 Guide the cable through the immersion assembly 7 Guide the cable through the rubber plug Ob...

Страница 17: ...ICE Pointed and sharp tools If unsuitable tools are used they can scratch the housing or damage the seal and thus negatively affect the leak tightness of the housing Do not use any sharp or pointed objects such as a knife to open the housing Only use a suitable Phillips head screwdriver to open and close the housing 1 2 3 4 10 Releasing housing screws in a diagonally opposite sequence with Phillip...

Страница 18: ...Current outputs and inputs relays not used in factory configuration LTE antenna E Do not use Do not use F Current outputs and inputs relays not used in factory configuration Ethernet G Current outputs and inputs relays not used in factory configuration Supply voltage H Freely usable Do not use I RS485 Out and M12 Ethernet M12 Ethernet used in factory configuration Do not use 6 4 Electrical connect...

Страница 19: ...WH GN YE BN WH GN YE 87 88 97 98 A B A B Alarm HART Power internal B A0015873 15 Overall wiring diagram for BASE E and extension power unit B Connecting the supply voltage power unit 100 to 230 V AC 1 Route the power supply cable through the appropriate cable entry and into the housing 2 Connect the protective ground of the power unit to the threaded bolt specially provided on the cable mounting r...

Страница 20: ...ith a wire ferrule or an open cable lug 6 4 3 Connecting the sensors All sensors are supplied either with a sensor cable with an M12 connector or with a measuring cable CYA10 with an M12 connector Connect the cable with the M12 connector to the M12 sensor socket provided on the underside of the device The transmitter is already wired at the factory 85 86 85 1 2 86 97 88 87 98 Sensor 1 PK GY GN YE ...

Страница 21: ...40V 1 N 1 Teltonica LTE Modem Kunbus RevPi 3 2 8 9 7 CPU Power A1 A2 5 L 2 3 4 5 6 7 8 3 1 4 6 A0037744 18 Modbus Device Edge preparation 1 Antenna connection cables for LTE antenna and LTE modem 2 Cable gland at connection port C 3 Cable gland at connection port D 4 Teltonica LTE modem 5 CPU Kunbus RevPi 3 6 Power unit only for Modbus Edge Device 100 to 240 VAC 7 Free connection of Teltonica LTE ...

Страница 22: ...dge Device 3 Pull the antenna connection cables through the cable glands on the Modbus Edge Device 4 To secure the antenna head drill an 11 mm bore in the mounting surface 5 Guide the antenna connection cables through the bore 6 Remove the protective film from the antenna head 7 Stick the antenna head to the mounting surface 8 Tighten the nut 9 Guide the antenna connection cables through cable gla...

Страница 23: ...1 1 2 3 L 2 3 PE A0037821 20 Connecting supply voltage 100 to 240 V AC 1 Terminal blocks 2 Cable entry 3 Power supply cable 1 Route the power supply cable into the housing through the cable gland at connection port G 2 Connect the protective ground to the green yellow terminal strip 1 3 Connect the neutral conductor N to the blue terminal strip 2 4 Connect phase L to the gray terminal strip 3 5 Cl...

Страница 24: ... housing through the cable gland at connection port G 2 Connect the protective ground to the green yellow terminal strip 1 3 Connect 0 V DC to the blue terminal strip 2 4 Connect 24 V DC to the gray terminal strip 3 5 Close the housing 17 6 6 Connecting Liquiline CM444 and Modbus Device Edge Signal transmission between the Liquiline CM444 transmitter and the Modbus Device Edge is via the Ethernet ...

Страница 25: ...ck Are the system devices and cables undamaged visual check Do the cables comply with the requirements Do the installed cables have adequate strain relief Does the supply voltage of the components match the specifications on the nameplate Is the terminal assignment correct Are all the housing covers closed Are all the housing screws securely fastened Are dummy plugs inserted in every unused cable ...

Страница 26: ...he housing 17 7 1 2 Setting the operating language 1 Switch on the supply voltage 2 Wait for the initialization to finish 3 Press the MENU soft key Set your language in the top menu item The device can now be operated in your chosen language 7 1 3 Configuring the Liquiline CM444 The Liquiline CM444 transmitter is preconfigured on delivery from Endress Hauser Take the following steps if you want ot...

Страница 27: ...hwater A AI 1 Sensor 1 primary value Oxygen content oxygen sensor COS61D Oxygen content oxygen sensor COS51D for salt water oxygen sensor COS61D for freshwater AI 2 Sensor 1 secondary value Temperature oxygen sensor COS61D Temperature oxygen sensor COS51D for salt water oxygen sensor COS61D for freshwater B AI 3 Sensor 2 primary value Ammonium ammonium and nitrate sensor CAS40D Oxygen content oxyg...

Страница 28: ...ion The Liquiline CM444 transmitter can be found by the Modbus Edge Device and read out data 7 2 Commissioning the Modbus Edge Device No settings need to be made on the Modbus Edge Device Once the Liquiline CM444 transmitter has been configured successfully the Modbus Edge Device connects to the transmitter Checking the connection if necessary 1 Open the housing of the Modbus Edge Device 17 2 Chec...

Страница 29: ...e discount code Nameplate 30 9 Enter the payment and invoicing data 10 Click the Buy button Once the payment has been made successfully the newly added devices are displayed in the overview 7 4 Installing a smartphone application Prerequisite The user owns the Smart System 28 1 Download the Smart Systems App from the Apple AppStore or Google Play Store 2 Install the Smart System App 3 Log in The d...

Страница 30: ...Nameplate Smart System for Aquacultures SSP200B 30 Endress Hauser 8 Nameplate ...

Страница 31: ...9 Diagnostics and troubleshooting 9 1 Smart System SSP For an overview of the alarms currently pending see the History view in the Smart System App 9 2 Liquiline CM444 For detailed information on transmitter diagnostics and troubleshooting see the Operating Instructions for Liquiline CM444 ...

Страница 32: ... recalibration maintenance service system tests or device tests Your Endress Hauser Sales Center can provide detailed information on the services 10 2 Smart System SSP 10 2 1 Updates Updates for the Smart System App are available from either the Apple AppStore or the Google Play Store Updates for the Modbus Edge Device are automatically installed by Endress Hauser Where necessary updates for the t...

Страница 33: ...ur Endress Hauser Sales Center at www addresses endress com 11 3 Endress Hauser services Endress Hauser offers a wide variety of services for maintenance such as recalibration maintenance service system tests or device tests Your Endress Hauser Sales Center can provide detailed information on the services 11 4 Liquiline CM444 For detailed information on repairing the transmitter see the Operating ...

Страница 34: ...Technical data Smart System for Aquacultures SSP200B 34 Endress Hauser 12 Technical data For detailed information on the technical data see the Technical Information for the particular product 6 ...

Страница 35: ......

Страница 36: ...www addresses endress com ...

Отзывы: